IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
16.1 Table: 14.3.4-12 Page:
1 of 1 0.35 FT2 SPLIT 30% POWER Time (sec)
Mass (lb/sec)
Energy (BTU/sec)
.1000E-01
.7970E+03
.9480E+06
.1000E+01
.7970E+03
.9480E+06
.3000E+01
.7890E+03
.9388E+06
.5000E+01
.7820E+03
.9308E+06
.7000E+01
.7760E+03
.7239E+06
.9000E+01
.7700E+03
.9169E+06
.1000E+02
.7680E+03
.9145E+06
.1300E+02
.7760E+03
.9237E+06
.1500E+02
.7800E+03
.9284E+06
.1600E+02
.8960E+03
.1066E+07
.1900E+02
.1240E+03
.1476E+07 2000E+02
.7720E+03
.9195E+06
.2500E+02
.7090E+03
.8466E+06
.3000E+02
.6630E+03
.7930E+06
.3500E+02
.6280E+03
.7520E+06
.4000E+02
.6010E+03
.7203E+06
.5000E+02
.5630E+03
.6756E+06
.6000E+02
.5350E+03
.6425E+06
.7000E+02
.5140E+03
.6176E+06
.8000E+02
.4970E+03
.5974E+06
.9000E+02
.4830E+03
.5808E+06
.1000E+03
.4700E+03
.5653E+06
.1200E+03
.4500E+03
.5415E+06
.1400E+03
.4320E+03
.5200E+06
.1600E+03
.4160E+03
.5008E+06
.1800E+03
.4020E+03
.4841E+06
.2000E+03
.3890E+03
.4685E+06
.2400E+03
.3650E+03
.4397E+06
.2800E+03
.3440E+03
.4144E+06
.3200E+03
.3240E+03
.3904E+06
.3600E+03
.3060E+03
.3687E+06
.4000E+03
.2890E+03
.3481E+06
.5000E+03
.2530E+03
.3046E+06
.6000E+03
.2230E+03
.2683E+06
.7000E+03
.1990E+03
.2392E+06
.8000E+03
.1790E+03
.2150E+06
.9000E+03
.1620E+03
.1944E+06
.1000E+04
.1480E+03
.1774E+06