ML16343A617

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3-4-8, Unit 1/Unit 2 Steamline Break Mass/Energy Releases Inside Containment 102% of 3588 Mwt Core Power, 0.860 ft2 Split Break .
ML16343A617
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A617 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

18.1 Table: 14.3.4-8 Page:

1 of 1 Unit 1 UNIT 1/UNIT 2 STEAMLINE BREAK MASS/ENERGY RELEASES INSIDE CONTAINMENT 102% OF 3588 MWt CORE POWER, 0.860 ft2 SPLIT BREAK FAILURE - AFWRP Time (sec)

Mass (lbm/sec)

Energy (MBtu/sec)

.0000

.0000

.0000

.2000 1394 1.669 5.600 1293 1.550 7.000 1439 1.724 10.00 1551 1.855 13.00 1627 1.944 13.60 1635 1.953 14.80 1642 1.961 15.60 1642 1.961 16.00 1640 1.959 18.00 1628 1.945 20.00 1540 1.843 21.00 1484 1.777 22.00 1433 1.718 23.00 1387 1.663 24.00 1345 1.614 26.00 1271 1.526 30.00 1153 1.386 35.00 1043 1.255 40.00 958.2 1.154 45.00 892.0 1.074 50.00 839.6 1.011 60.00 767.2 0.924 70.00 719.7

.8668 80.00 689.9

.8308 90.00 669.6

.8063 100.0 656.4

.7904 110.0 648.7

.7810 120.0 643.8

.7752 150.0 638.2

.7684 200.0 635.4

.7650 295.0 630.9

.7596 315.0 459.0

.5513 335.0 269.0

.3211 350.0 213.2

.2537 400.0 189.1

.2247 500.0 188.8

.2243 602.5 189.9

.2257 605.0 198.2

.2348 610.0 114.2

.1343