ML16343A443

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3-4-2, Deck Leakage Sensitivity
ML16343A443
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A443 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

19.2 Table: 14.3.4-2 Page:

1 of 1 DECK LEAKAGE SENSITIVITY Break Size 5 ft2 Deck Leak Air Compression Peak (psig) 1 Deck Leakage Area (ft2)

Spray Flow Rate (gpm)

Resultant Peak Containment Pressure (psig)

Double ended 7.8 54 0

12.0 0.6 double ended 6.6 46 0

12.0 3 ft2 6.25 50 0

12.0 8-inch diameter 5.5 56 4000 12.2 8-inch diameter 5.5 35 2000 12.0 8-inch diameter 2 5.5 56 2000 11.3 6-inch diameter 5.0 56 4000 10.4 2 1/2-inch diameter 4.0 56 4000 8.5 1/2-inch diameter 3.0 50 4000 3.0 1 The current design basis value for the deck leakage is 7 sq. ft.

2 This case assumes upper compartment structural heat sink steam condensation of 8 lb/sec and 30 percent of deck leakage is air.