ML16343A428

From kanterella
Jump to navigation Jump to search
Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3-1-4B, Minimum Centrifugal Charging Pump (Ccp) Injection Flow
ML16343A428
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A428 (1)


Text

I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T T Revision: 23Table: 14.3.1-4B Page: 1 of 1 MINIMUM CENTRIFUGAL CHARGING PUMP (CCP) INJECTION FLOW Pressure (psia) Total CCP Injected Flow (gpm) 14.7 283.2 114.7 253.5 214.7 247.3 314.7 247.0 414.7 243.7 514.7 233.4 614.7 214.9 714.7 195.9 814.7 176.3 914.7 155.9 1014.7 134.7 1114.7 112.4 1214.7 88.9 1314.7 63.8 1414.7 36.3 1514.7 9.1 1614.7 0.0 1714.7 0.0