ML16343A205

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.A.3-2 - Parameters Used in the Calculation of Reactor Coolant Corrosion Product Activities
ML16343A205
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A205 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

23 Table: 14.A.3-2 Page:

1 of 1 PARAMETERS USED IN THE CALCULATION OF REACTOR COOLANT CORROSION PRODUCT ACTIVITIES

1.

Core thermal power, max. calculated, MWt 3391

2.

Fraction of fuel containing clad defects 0.01

3.

Reactor coolant liquid volume, ft3 12,560

4.

Reactor coolant average temperature, oF 568

5.

Purification flow rate (normal), gpm 75

6.

Effective cation demineralizer flow, gpm 7.5

7.

Volume control tank volumes

a. Vapor, ft3 280
b. Liquid, ft3 120
8.

Fission product escape rate coefficients:

a. Noble gas isotopes, sec-1 6.5 x 10-8
b. Br, I and Cs isotopes, sec-1 1.3 x 10-8
c. Te isotopes, sec-1 1.0 x 10-9
d. Mo isotopes, sec-1 2.0 x 10-9
e. Sr and Ba isotopes, sec-1 1.0 x 10-11
f.

Y, La, Ce, Pr isotopes, sec-1 1.6 x 10-12

9.

Mixed bed demineralizer decontamination factors:

a. Noble gases and Cs-134, 136, 137, Y-90, 91 and Mo-99 1.0
b. All other isotopes 10.0 10.0
10. Cation bed demineralizer decontamination factor for Cs-134, 136, 137, Y-90, 91 and Mo-99
11. Volume control tank noble gas stripping fraction (closed system):

Isotope Stripping Fraction Kr-85 2.3 x 10-5 Kr-85m 2.7 x 10-1 Kr-87 6.0 x 10-1 Kr-88 4.3 x 10-1 Xe-133 1.6 x 10-2 Xe-133m 3.7 x 10-2 Xe-135 1.8 x 10-1 Xe-135m 8.0 x 10-1 Xe-138 1.0