7 to Updated Final Safety Analysis Report, Chapter 14, Table 14.3.2-7, Safety Injection Flows Used in the SBLOCA Analysis - Recirculation Phase (1 Chg Pump, 1 HHSI Pump, 1 RHR Pump - Faulted Loop.
ML16343A149
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A149 (2)


Text

INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-7 Sheet:

1 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Recirculation Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump -

faulted loop CHG flow injects to RCS pressure and faulted loop HHSI/RHR flow spills to containment (0 psia) - RHR Spray active - 8.75-inch break)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 - CHG Loop 1 -

RHR/HHSI Loop 2 Loop 3 Loop 4 14.7 15.4 20.7 32.1 31.3 32.3 34.7 15.4 39.8 31.9 12.4 32.0 54.7 15.3 39.9 31.6 12.4 31.8 74.7 15.3 40.0 31.4 12.3 31.5 94.7 15.2 40.1 31.1 12.2 31.2 114.7 15.1 40.3 30.8 12.2 31.0 134.7 15.0 40.4 30.6 12.1 30.7 154.7 15.0 40.5 30.3 12.1 30.4 174.7 14.9 40.6 30.0 12.0 30.1 194.7 14.8 40.8 29.7 12.0 29.9 214.7 14.8 40.9 29.4 11.9 29.6 234.7 14.7 41.1 29.2 11.8 29.3 254.7 14.6 41.2 28.9 11.8 29.0 274.7 14.5 41.3 28.6 11.7 28.7 294.7 14.5 41.4 28.3 11.7 28.4 314.7 14.4 41.6 28.0 11.6 28.1 414.7 14.1 42.2 26.5 11.3 26.6 514.7 13.7 42.9 24.9 11.0 25.0 614.7 13.3 55.9 22.6 10.7 22.6 714.7 12.8 57.8 19.8 10.4 19.8 814.7 12.4 59.8 16.5 10.0 16.6

INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-7 Sheet:

2 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Recirculation Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump -

faulted loop CHG flow injects to RCS pressure and faulted loop HHSI/RHR flow spills to containment (0 psia) - RHR Spray active - 8.75-inch break)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 - CHG Loop 1 -

RHR/HHSI Loop 2 Loop 3 Loop 4 914.7 12.0 62.2 12.7 9.7 12.7 1014.7 11.6 64.3 9.3 9.3 9.3 1114.7 11.1 64.3 9.0 9.0 9.0 1214.7 10.7 64.3 8.6 8.6 8.6 1314.7 10.2 64.3 8.3 8.3 8.3 1414.7 9.8 64.3 7.9 7.9 7.9 1514.7 9.2 64.4 7.4 7.4 7.4 1614.7 8.7 64.4 7.0 7.0 7.0 1714.7 8.1 64.4 6.6 6.6 6.6