INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-6 Sheet:

1 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Recirculation Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop injects to RCS pressure -

RHR Spray active - 1.5-through 6-inch breaks)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 Loop 2 Loop 3 Loop 4 14.7 36.1 32.1 31.3 32.3 34.7 35.9 31.9 31.1 32.1 54.7 35.7 31.7 30.9 31.9 74.7 35.5 31.5 30.7 31.7 94.7 35.3 31.3 30.5 31.5 114.7 35.0 31.1 30.3 31.3 134.7 34.8 30.9 30.1 31.1 154.7 34.6 30.7 29.9 30.9 174.7 34.3 30.5 29.7 30.6 194.7 34.1 30.3 29.5 30.4 214.7 33.9 30.1 29.3 30.2 234.7 33.6 29.9 29.1 30.0 254.7 33.4 29.6 28.9 29.8 274.7 33.2 29.4 28.7 29.6 294.7 32.9 29.2 28.4 29.3 314.7 32.7 29.0 28.2 29.1 414.7 31.5 27.9 27.2 28.0 514.7 30.2 26.7 26.0 26.8 614.7 28.8 25.5 24.9 25.6 714.7 27.4 24.2 23.6 24.3 814.7 26.0 22.9 22.3 23.0 914.7 24.5 21.5 21.0 21.6 1014.7 22.6 19.9 19.4 20.0

INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-6 Sheet:

2 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Recirculation Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop injects to RCS pressure -

RHR Spray active - 1.5-through 6-inch breaks)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 Loop 2 Loop 3 Loop 4 1114.7 20.7 18.1 17.7 18.1 1214.7 18.4 15.9 15.6 16.0 1314.7 15.3 13.0 12.8 13.1 1414.7 11.4 9.4 9.3 9.4 1514.7 9.2 7.4 7.4 7.4 1614.7 8.7 7.0 7.0 7.0 1714.7 8.1 6.6 6.6 6.6