INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-5 Sheet:

1 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Injection Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop CHG flow injects to RCS pressure and faulted loop HHSI / RHR flow spills to containment (0 psia) - 8.75-inch break)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 CHG Loop 1 RHR / HHSI Loop 2 Loop 3 Loop 4 14.7 16.34 157.03 139.36 156.01 140.26 34.7 16.27 215.73 126.84 99.71 127.64 54.7 16.20 274.56 115.46 32.18 116.17 74.7 16.13 303.81 97.04 12.90 97.63 94.7 16.06 323.64 72.95 12.84 73.37 114.7 15.98 345.72 43.70 12.78 43.93 134.7 15.91 365.86 12.73 12.73 12.73 154.7 15.84 365.86 12.67 12.67 12.67 214.7 15.63 365.86 12.50 12.50 12.50 314.7 15.25 365.86 12.21 12.21 12.21 414.7 14.83 365.86 11.90 11.90 11.90 514.7 14.45 365.86 11.57 11.57 11.57 614.7 14.03 365.86 11.23 11.23 11.23 714.7 13.60 365.86 10.88 10.88 10.88 814.7 13.17 365.86 10.54 10.54 10.54 914.7 12.73 365.86 10.18 10.18 10.18 1014.7 12.29 365.86 9.82 9.82 9.82 1114.7 11.83 365.86 9.46 9.46 9.46 1214.7 11.38 365.86 9.10 9.10 9.10

INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-5 Sheet:

2 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Injection Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop CHG flow injects to RCS pressure and faulted loop HHSI / RHR flow spills to containment (0 psia) - 8.75-inch break)

RCS Pressure (psia)

Broken Loop (lbm/sec)

Intact Loops (lbm/sec)

Loop 1 CHG Loop 1 RHR / HHSI Loop 2 Loop 3 Loop 4 1314.7 10.88 365.86 8.70 8.70 8.70 1414.7 10.36 365.86 8.29 8.29 8.29 1514.7 9.82 365.86 7.86 7.86 7.86 1614.7 9.27 365.86 7.42 7.42 7.42 1714.7 8.72 365.86 6.98 6.98 6.98 1814.7 8.08 365.86 6.47 6.47 6.47 1914.7 7.41 365.86 5.93 5.93 5.93 2014.7 6.72 365.86 5.38 5.38 5.38 2114.7 5.94 365.86 4.76 4.76 4.76 2214.7 5.02 365.86 4.01 4.01 4.01 2314.7 0

365.86 0

0 0