INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-4 Sheet:
1 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Injection Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop injects to RCS pressure - 1.5-inch through 6-inch breaks)
RCS Pressure (psia)
Broken Loop (lbm/sec)
Intact Loops (lbm/sec)
Loop 1 Loop 2 Loop 3 Loop 4 14.7 188.63 158.38 175.00 159.93 114.7 127.20 102.43 117.32 103.38 214.7 38.89 12.50 34.37 12.50 314.7 37.49 12.21 33.10 12.21 414.7 35.93 11.90 31.73 11.90 514.7 34.30 11.57 30.26 11.57 614.7 32.56 11.23 28.64 11.23 714.7 30.73 10.88 26.98 10.88 814.7 28.80 10.54 25.22 10.54 914.7 26.74 10.18 23.35 10.18 1014.7 24.34 9.82 21.14 9.82 1114.7 21.49 9.46 18.54 9.46 1214.7 18.00 9.10 15.32 9.10 1314.7 13.03 8.70 10.73 8.70 1414.7 10.36 8.29 8.29 8.29 1514.7 9.82 7.86 7.86 7.86 1614.7 9.27 7.42 7.42 7.42 1714.7 8.72 6.98 6.98 6.98 1814.7 8.08 6.47 6.47 6.47
INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 25.0 Table: 14.3.2-4 Sheet:
2 of 2 Unit 1 Last Revised: Revision 25.0 Safety Injection Flows Used in the SBLOCA Analysis - Injection Phase (1 CHG pump, 1 HHSI pump, 1 RHR pump - faulted loop injects to RCS pressure - 1.5-inch through 6-inch breaks)
RCS Pressure (psia)
Broken Loop (lbm/sec)
Intact Loops (lbm/sec)
Loop 1 Loop 2 Loop 3 Loop 4 1914.7 7.41 5.93 5.93 5.93 2014.7 6.72 5.38 5.38 5.38 2114.7 5.94 4.76 4.76 4.76 2214.7 5.02 4.01 4.01 4.01 2314.7 0
0 0
0