Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

23 Table: 11.2-11 Page:

1 of 1 GAP ACTIVITY CIRCULATING IN RESIDUAL HEAT REMOVAL LOOP, MEV/CC-SEC GAMMA ENERGY (MEV/PHOTON)

TIME AFTER RELEASE 0.4 0.8 1.3 1.7 2.2 2.5 3.5 0 HR 1.63x107 1.31x108 8.54x106 4.90x106 4.61x106 1.70x106 4.50x105 0.5 HR 1.51x107 1.23x108 7.56x106 4.16x106 4.16x106 1.61x106 3.78x105 1 HR 1.39x107 1.14x108 6.18x106 3.46x106 3.67x106 1.20x106 2.78x105 2 HR 1.28x107 1.03x108 4.59x106 2.53x106 3.01x106 8.24x105 2.00x105 8 HR 1.11x107 7.75x107 7.16x105 4.16x105 5.61x105 1.30x105 2.51x104 1 DY 1.03x107 6.99x107 4.84x104 1.82x104 1.75x105 7.07x103 9.96x101 1 WK 9.54x106 4.88x107 1.16x102 2.93x102 1 MO 1.21x106 4.69x107 6 MO 4.16x104 1.56x107 1 YR 1.22x103 1.31x107