IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

11.2-4 Page:

1 of 1 ACCIDENT SHIELD DESIGN PARAMETERS TID-14844 RELEASE Core thermal power 3391 MW Minimum full power operating time 650 days Equivalent fraction of core melting 1.0 Fission product fractional releases:

Noble gases 1.0 Halogens 0.5 Remaining fission product inventory 0.01 Clean-up rate following accident 0

Maximum integrated dose (infinite exposure) in the control room

<1 rem GAP ACTIVITY RELEASE Core Thermal Power, MW 3391 Minimum full power operating time, days 650 Equivalent fraction fuel rod failure 1.0 Fraction of gap activity absorbed by sump water:

Noble Gases 0.0 All Other 1.0 Cleanup rate following accident 0.0 Sump water volume, ft3:

Reactor Coolant 12,560 Refueling Water 46,800 Accumulators 4,000 Total 63,360 ft 3