ML16343A019

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 11, Table 11.1-3
ML16343A019
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A019 (2)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

11.1-3 Page:

1 of 2 COMPONENT

SUMMARY

DATA TANKS QUANTITY TYPE VOLUME DESIGN PRESSURE DESIGN TEMP.oF MATERIAL (1)

Reactor Coolant Drain (per unit) 1 Horiz 350 gal 25 psig 267 ss Laundry & Hot Shower 2 (2)

Vert 600 gal Atm 180 ss Chemical Drain 1 (2)

Vert 600 gal Atm 180 ss Clean Sump 1 (2)

Vert 600 gal Atm 180 ss Station Drainage Sump 1 (2)

Vert 525 gal Atm 180 ss Waste Holdup 2 (2)

Horiz 24,700 gal Atm 180 ss Waste Condensate 2 (2)

Vert 6,450 gal Atm 180 ss Gas Decay 8 (2)

Vert 600 ft3 150 psig 180 cs Waste Evaporator Bottoms Storage 1 (2)

Vert 4,000 gal Atm 250 ss Spent Resin Storage 1 (2)

Vert 300 ft3 100 psig 180 ss PUMPS QUANTITY TYPE FLOW gpm HEAD ft.

DESIGN PRESSURE psig DESIGN TEMP oF MATERIAL (1)

Reactor Coolant Drain (A)

(per unit) 1 Horiz canned 50 175 150 300 ss Reactor Coolant Drain (B)

(per unit) 1 Horiz canned 150 175 150 300 ss Chemical Drain 1 (2)

Horiz 20 100 150 180 ss Laundry & Hot Shower 1 (2)

Horiz (3) 20 100 150 180 ss Sump Tank 2 (2)

Horiz (3) 20 100 150 180 ss Waste Evaporator 2 (2)

Horiz 20 100 150 180 ss Waste Condensate 2 (2)

Horiz (3) 150 200 150 180 ss Waste Evaporator Bottoms Storage Tank 1 (2)

Horiz (3) 20 60 150 180 ss (1) Material contacting fluid (2) Shared by Units 1 and 2 (3) Mechanical seal provided (2) Shared by Units 1 and 2 (3) Mechanical seal provided

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

11.1-3 Page:

2 of 2 MISCELLANEOUS EQUIPMENT QUANTITY CAPACITY TYPE Waste Evaporator 1(2) 15 gpm Forced Circulation Flash (Incoloy - 825 tubes)

Boric Acid/Waste Evaporator 1(2) 15 gpm Submerged Tube (Incoloy - 825 tubes)

Waste Gas Compressors 2(2) 40 CFM Liquid piston rotary (3)

QUANTITY TYPE CAPACITY DESIGN PRESSURE psig DESIGN TEMP.

oF MATERIAL (1)

Waste Evaporator Condensate Filter 1(2)

Disposable cartridge 20 gpm 150 180 ss Waste Evaporator Condensate Demineralizer 1(2)

Flushable 30 ft3 100 250 ss