IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

20.2 Table:

11.1-2 Page:

1 of 1 WASTE DISPOSAL COMPONENTS CODE REQUIREMENTS1 COMPONENT CODE Chemical Drain Tank No code Reactor Coolant Drain Tanks ASME III, 2 Class C Sump Tanks No code Waste Holdup Tank No code Waste Evaporator Condensate Tank No code Laundry and Hot Shower Tank No code Waste Evaporator(s)

No code Waste Filters ASME III,(2) Class C Piping and Valves USAS-B31.13, Section 1 ASME III Appendix F 4 Gas Decay Tank ASME III,(2) Class C Spent Resin Storage Tank ASME III,(2) Class C Waste Evaporator Condensate Demineralizer ASME III,(2) Class C Waste Evaporator Condensate Filter ASME III,(2) Class C Waste Evaporator Bottoms Storage Tank No code 1 Repairs and replacements for pressure retaining components within the code boundary, and their supports, are conducted in accordance with ASME Section XI 2 ASME III American Society of Mechanical Engineers, Boiler and Pressure Vessel Code,Section III, Nuclear Vessels.

3 USAS-B31.1 American Standards Association Code for pressure piping and special nuclear cases where applicable.

4 The evaluation criteria of ASME III Appendix F (faulted conditions) is applicable to 1) piping from normally closed PRT drain line isolation valve and the RCDT drain line check valve inside containment to the normally closed isolation valve outside containment (U-1 & U-2); and 2) piping between containment sump pump discharge check valves inside containment and discharge isolation valve outside containment (U-1 only).