ML16342E038

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-275/98-04 & 50-323/98-04 on 980112-30 W/In Ofc Insp Continuing Until 980219.No Violations Noted. Insp Determined That Licensee Had Good CA Program.Conditions That Could Degrade Quality of Operation Was Resolved
ML16342E038
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 03/20/1998
From: Powers D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Rueger G
PACIFIC GAS & ELECTRIC CO.
Shared Package
ML16342E039 List:
References
50-275-98-04, 50-275-98-4, 50-323-98-04, 50-323-98-4, NUDOCS 9804010067
Download: ML16342E038 (12)


See also: IR 05000275/1998004

Text

4A.J ZaVVIC.I

4

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9804010067

DOC.DATE: 98/03/20

NOTARIZED: NO

FACIL:50-275 Diablo Canyon Nuclear

Power Plant, Unit 1, Pacific

Ga

50-323 Diablo Canyon Nuclear

Power Plant, Unit 2, Pacific

Ga

AUTH.NAME

AUTHOR AFFILIATION

POWERS,D.A.

Region

4 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

RUEGER,G.M.

Pacific Gas

& Electric Co.

DOCKET

0500027

P

05000323

SUBJECT:

Forwards insp repts 50-275/98-04

&. 50-323/98-04

on 980112-30

w/in ofc insp continuing until 980219.No violations noted.

Insp determined that licensee

had good

CA program. Conditions

that could degrade quality of operation

was resolved.

DTSTRTBUTTON CODE:

TE01F

COP1ES

RECEIVED:LTR

i

ENCLI

S1EE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES:

RECIPIENT

ID CODE/NAME

PD4-2

PD

COPIES

LTTR ENCL

1

1

RECIPIENT

ID CODE/NAME

BLOOM,S

COPIES

LTTR ENCL

1

1

INTERNAL: ACRS

AEO

TC

FILE~CE

ER

ECB

NUDOCS-ABSTRACT

OGC/HDS3

TERNAL: LITCO BRYCE, J H

NRC PDR

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

AEOD/SPD/RAB

DEDRO

NRR/DRCH/HHFB

NRR/DRPM/PERB

OE DIR

RGN4

FILE

01

NOAC

NUDOCS FULLTEZT

1

1

1

1

1

'

1

1

1

1

1

1

1

1

1

1

~@~

((cf4~1~

p~t

r)~le p)y

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LIS'J

OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTRC

DESK

tDCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

19

ENCL

19

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION IV

611 RYAN PLAZA DRIVE, SUITE 400

ARLINGTON,TEXAS 76011.8064

March 20, 1998

Gregory M. Rueger, Senior Vice President

and General Manager

Nuclear Power Generation Bus. Unit

Pacific Gas and Electric Company

Nuclear Power Generation, B14A

77 Beale Street, Room 1451

P.O. Box 770000

San Francisco, California 94177

SUBJECT:

NRC INSPECTION REPORT 50-275/98-04; 50-323/98-04

Dear Mr. Rueger:

From January 12-30, 1998, an NRC inspection of the implementation of your corrective action

program was conducted at your Diablo Canyon Nuclear Power Plant, Units 1 and 2, reactor

facilities. Following the exit meeting, the results of further review of information and material

presented

on the last day of this inspection were discussed

in a supplemental telephone exit, on

February 19, 1998, with Mr. T. Grebel and other members of your staff. The enclosed report

presents the scope and results of that inspection.

The inspection determined that you had a good corrective action program.

Conditions that could

degrade the quality of plant operations were being effectively identified, resolved, and corrected.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its

enclosure will be placed in the NRC Public Document Room (PDR).

Should you have any questions concerning this inspection, we will be pleased to discuss them

with you.

Sincerely,

Dr. Dale A. Powers, Chief

Maintenance Branch

Division of Reactor Safety

Docket Nos.:

50-275; 50-323

License Nos.: DPR-80; DPR-82

98040i0067

980320

PDR

ADOCK 05000275

8

PDR

Pacific Gas and Electric Company

-2-

Enclosure:

NRC Inspection Report

50-275/98-04; 50-323/98-04

cc w/enclosure:

Dr. Richard Ferguson

Energy Chair

Sierra Club California

1100 11th Street, Suite 311

Sacramento,

California 95814

Ms. Nancy Culver

San Luis Obispo Mothers for Peace

P.O. Box 164

Pismo Beach, California 93448

Chairman

San Luis Obispo County Board of

Supervisors

Room 370

County Government Center

San Luis Obispo, California 93408

Mr. Truman Burns)Mr. Robert Kinosian

California Public Utilities Commission

505 Van Ness, Rm. 4102

San Francisco, California 94102

Robert R. Wellington, Esq.

Legal Counsel

Diablo Canyon Independent Safety Committee

857 Cass Street, Suite D

Monterey, California 93940

Mr. Steve Hsu

Radiologic Health Branch

State Department of Health Services

P.O. Box 942732

Sacramento,

California 94234

Christopher J. Warner, Esq.

Pacific Gas and Electric Company

P.O. Box 7442

San Francisco, California 94120

0

Pacific Gas and Electric Company

Robert P. Powers, Vice President

and Plant Manager"

Diablo Canyon Nuclear Power Plant

P.O. Box 56

Avila Beach, California 93424

Managing Editor

Telegram-Tribune

1321 Johnson Avenue

P.O. Box 112

San Luis Obispo, California 93406

Pacific Gas and Electric Company

E-Mail report to T. Frye (TJF)

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

bcc to DCD (IE01)

bcc distrib. by RIV:

Regional Administrator

DRS Director

DRP Director

Branch Chief (DRP/E, WCFO)

Senior Project Inspector (DRP/E, WCFO)

Branch Chief (DRP/TSS)

WCFO File

Resident Inspector

DRS Deputy Director

DRS-PSB

MIS System

RIV File

DOCUMENT NAME: R:i DC'tDC804RP.WPA

To receive copy of document, indicate in box: "C" = Copy without enctosures

"E" = Copy with enciosures "N""-No copy

RIV:SRI:MB

WPAng*

03/19/98

RI:PBE

DBAllen*

03/15/98

Rl:MB

C:PBE

CAClark*

HJWong*

03/1 9/98

3/19/98

OFFICIAL RECORD COPY

C:MB

DAPowers

03/20/98

Pacific Gas and Electric Company

4

E-Mail report to T. Frye (TJF)

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

bcc to DCD (IE01)

bcc distrib. by RIV:

Regional Administrator

DRS Director

DRP Director

Branch Chief (DRP/E, WCFO)

Senior Project Inspector (DRP/E, WCFO)

Branch Chief (DRP/TSS)

WCFO File

Resident Inspector

DRS Deputy Director

DRS-PSB

MIS System

RIV File

DOCUMENT NAME: R:tt DC'tDC804RP.WPA

To receive copy of document, indicate in box: "C" = Copy without enctosures

"E" = Copy with enctosures

"N"= No copy

RIV:SRI:MB

WPAng*

03/19/98

Rl:PBE

DBAIlen*

03/15/98

C:PBE

Rl:MB

CAClark*

HJWong*

3/19/98

03/19/98

OFFICIAL RECORD COPY

C:MB

DAPowers

03/20/98