Discusses Review of Rev 3 Change 13 to Plant Emergency Plan in Accordance w/10CFR50.54(q).Concludes That All Changes Continues to Meet Stds in 10CFR50.47 & Requirements of App E to Part 50
ML16342A362
Person / Time
Site: Diablo Canyon  
Issue date: 01/06/1994
From: Pate R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Rueger G
PACIFIC GAS & ELECTRIC CO.
References
NUDOCS 9401130029
Download: ML16342A362 (4)


Text

~lE IIEOy (4

P0 fy Cl I

Vh 1

0 Op

/yIP Cp

+>>*<<+

0 UNITED STATES-NUCLEAR REGULATORYCOMMISSION REGION V 1450 MARIALANE WALNUTCREEK, CALIFORNIA94596-5368

494, 6

ggg4 Docket Nos. '50-275 and 50-323 License Nos.

DPR-80 and DPR-82 Pacific Gas and Electric Company Nuclear Power Generation, B14A77 77 Beale Street, Room 1451 P. 0.

Box 770000 San Francisco, California 94177 Attention:

Mr. Gregory H. Rueger Senior Vice President and General Manager Nuclear Power Generation Business Unit

SUBJECT:

REVIEW OF REVISION 3, CHANGE 13, TO THE DIABLO CANYON POWER PLANT UNITS 1

AND 2 EMERGENCY PLAN This letter refers to Revision 3, Change 13, to the Diablo Canyon Emergency Plan, which was sent to us for review on October 7, 1993, in accordance with 10 CFR 50.54(q).

I We have completed our review of the emergency plan changers Hs.

G.

Good discussed the results of our review and obtained clarification of some of the changes during a January 4,

1994, conference call with Ms. L. Hagan and Messrs.

H. Hug, E.

Waage, and D.

Yows.

All of our questions/comments were satisfactorily resolved during the conference call.

Your staff agreed to correct several minor issues in the. next emergency plan change.

Our review indicates that your emergency plan continues to meet the standards in 10 CFR 50.47(b) and the requirements of Appendix E to Part 50; Sincerely, ober J.

a e, Chief Safeguards, Emergency Preparedness, and Non-Power Reactor Branch CC:

Dr. Richard Ferguson, Energy Chair, Sierra Club California Hs. Nancy'ulv'er, San Luis Obispo Mothers for Peace Hs. Jacquelyn C. Wheeler Hanaging Editor, The County Telegram Tribune

Chairman, San Luis Obispo County Board of Supervisors Hr. Truman Burns, California Public Utilities Commission Mr. Robert Kinosian, California Public Utilities Commission Robert R. Wellington, Esq.,

Diablo Canyon Independent Safety Committee 9401i30029 940106 PDR ADOCK 05000275 F

'DR

+~ z9

(16)

Page 261 (8.2.3) - does the last sentence in the first paragraph mean that contracts will not be reviewed annually?

~Res onse:

Narty and Ed agreed that the wording did not clearly indicate that an annual review would be performed for multi-year contracts.

Harty said that the wording would be strengthened in the next plan change.

This response was acceptable.

(17) Appendix N - sections of this supplement (Table of Contents only) were revised September 1993.

Region IV/V will send you an official copy (probably after Harch 1994),

unless a copy is needed sooner.

~Res onse:

Narty said that they could wait until they receive the "formal" copy.

This response was acceptable.

(18) General there were several pages that had changes without change bars (26, 74, 95, 191, 259).

~Res onse:

Dennis explained that change bars were only used for the first occurrence of global changes.

Harty said that a statement to this effect would be included with future emergency plan change summaries.

Dennis said that the other changes should have had change bars.

Th'is response was acceptable.

D.

Conclusion All of the changes continued to meet the standards in 10 CFR 50,47(b) and the requirements of Appendix E to Part 50.

OflPIAaf$fpn+ py Gail H.

Good Emergency Preparedness Analyst bcc: Central Files A. HcQueen RV/gmd EST COPY REQUEST P

SEND~

PDR TO DCS YE NO ~~

YES/NO YES~O Y

NO Good M~

RPate I/+/94 I/P /94