ML16341F529

From kanterella
Jump to navigation Jump to search
Responds to NRC Bulletin 88-011 & Forwards Nonproprietary WCAP-12416, Evaluation of Thermal Stratification for Diablo Canyon Units 1 & 2 Pressurizer Surge Line, & Proprietary WCAP-12415.Proprietary Rept Withheld (Ref 10CFR2.790(b)(4))
Date released: 01/20/2020 Download: ML16341F529


Nonproprietary WCAP-12416, Evaluation of Thermal Stratification for Diablo Canyon Units 1 & 2 Pressurizer Surge Line.
ML20006C668
Person / Time
Site: Diablo Canyon 
Issue date: 11/30/1989
From: Coslow B, Maurer B, Mutyala B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML20006C668 (156)
Requests That Proprietary WCAP-12415, Evaluation of Thermal Stratification for Diablo Canyon Units 1 & 2 Pressurizer Surge Line, Be Withheld (Ref 10CFR2.790(b)(4))
ML16341F530
Person / Time
Site: Diablo Canyon 
Issue date: 12/18/1989
From: Wiesemann R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MURLEY T
Office of Nuclear Reactor Regulation
References
Download: ML16341F530 (20)
Responds to NRC Bulletin 88-011 & Forwards Nonproprietary WCAP-12416, Evaluation of Thermal Stratification for Diablo Canyon Units 1 & 2 Pressurizer Surge Line, & Proprietary WCAP-12415.Proprietary Rept Withheld (Ref 10CFR2.790(b)(4))
ML16341F528
Person / Time
Site: Diablo Canyon 
Issue date: 02/01/1990
From: Shiffer J
PACIFIC GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML16341F528 (6)