IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
23 Table:
9.10-1 Page:
1 of 1 CONTROL ROOM VENTILATION SYSTEM MALFUNCTION ANALYSIS COMPONENT MALFUNCTION COMMENTS AND CONSEQUENCES
- 1.
Normal Intake Dampers Failure to close Two dampers in series ensure isolation of outside air normal intake.
Failure to open Parallel dampers ensure outside air intake opens.
- 2.
Pressurization/Cleanup Intake Dampers Fully open or multiple dampers open One damper partially open is correct alignment. A single failure may result in one damper fully open or 2 dampers partially open. Other failures are not considered credible.
- 3.
Pressurization/Cleanup Recirculation Damper Failed to closed position All air flowing through the filter is from the intake and air cleanup is limited to a single pass. Control Room dose consequences may increase. The position of the recirculation damper is administratively controlled so it does not need to change position in response to a radiological accident.