IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

9.7-2 Page:

1 of 1 COMMON MODULE DATA Storage cell inside dimension:

8.75" + 0.04" Storage cell height (above the baseplate):

168 + 1/16" Baseplate thickness:

0.75" (nominal)

Support leg height:

5.25" (nominal)

Support leg type:

Remotely adjustable legs Number of support legs:

4 (minimum)

Remote lifting and handling provision:

Yes Poison material:

Boral Poison length:

144" Poison width:

7.5" Cell Pitch:

8.97" (nominal)