ML16341B950

From kanterella
Jump to navigation Jump to search
Board Notification 83-83:forwards Info Re Violations of NRC Reporting Requirements Re Min Wall Thickness on RCS Piping
ML16341B950
Person / Time
Site: Diablo Canyon 
Issue date: 06/24/1983
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Ahearne J, Gilinsky V, Palladino N
NRC COMMISSION (OCM)
Shared Package
ML16340D506 List:
References
TASK-AS, TASK-BN83-083, TASK-BN83-83 BN-83-083, BN-83-83, NUDOCS 8305110492
Download: ML16341B950 (6)


Text

Og 0

0 Docket No:

50-275 MEMORANDUM FOR:

Chairman Palladino Commissioner Gilinsky Commissioner Ahearne Commissioner Roberts Commissioner Asselstine FROt1:

SUBJECT:

Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation NOTICE OF VIOLATION CONCERNING REPORTING REQUIREMENTS FOR DIABLO CANYON (Board Notification No, 83-83)

According to the procedures for Board Notification, the enclosed information is being transmitted directly to the Commission.

The Boards and Parties are being notified by copy of this memorandum.

This information concerns a violation of NRC reporting requirements.

The subject of the notice of violation was previously reported to you and was the subject of Board Notification 83-72.

Enclosure:

As Stated aX s u<

.0 gSfn

~ggey STgei Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation cc vr/encl:

See Next Page 8305110492

Contact:

B. Buckley, NRR OFFICE%

SURNAME$

x 0

~ ~\\

0 ~

~ 0 ~ ~ OHO

~

DATEf

~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

DL/

g3

/L

~ 0 ~

~ OOHO ~ 0 ~ 0 ~

BBuc ey;mj TNo

~ 0 ~ 0 ~\\

F 0' OOHO ~ 0 ~

/

/8

~ et te ~ 00 ~ 0000 0 ~

~ tooe ~

eto ~ 0 000 ~ ~oott 6

3 DL

~ 0 ~ 0 ~ ~ 0 ~

~

~

~

F 0

'Hi

~ ~ 0 ~ 0 ~ 0 ~ 0 ~ 00 ~ 0 ~

0 ~ 0 ~ 0

~ ~

6/

/83

~

~ ~ 0 ~ 0

~ OHO

~ ~ ~ ~ ~ ~

~ 0

~ ~ ~ 0 ~ ~

~ 0 ~ ~ 0 ~ ~ ~ ~

~ ~

D 't

~ ~ ~ ~ 0 ~ 0 ~ 0 ~ 0 ~ 00 ~ 0000 ~ 0 ~ 0 ~

6/')

/83

~ 0 ~ 0 ~ 0 ~

~

~ 0 ~ 00 ~ 0 ~ 0 ~

NRG FORM 318 OO-80) NRCM 0240 FICIAL RECORD COPY USGPO: 1981~990

'0 I

f

cc: w/encl:

J.

F. Wolf, ASLB G.

O. Bright, ASLB J. Kline, ASLB T.

S. Noore, ASLAB W.

R. Johnson, ASLAB J.

H. Buck, ASLAB SECY OGC OPE EDO Parties to Proceeding

DISTRIBUTION LIST FOR BOARD NOTIFICATION Diablo Canyon Units 182 Docket Nos.

50-275/323 OL Ms. Elizabeth Apfelberg Mr. Richard E. Blankenburg Mr. Glenn 0. Bright Mr. Herbert H.

Brown Dr. John H. Buck Philip A. Crane, Jr.,

Esq.

Mr. Frederick Eissler David S. Fleischaker, Esq.

Mrs.

Raye Fleming Arthur C,-Gehr, Esq.

Mr. Mark Gottlieb Mr. Thomas H. Harris Mr..Richard B. Hubbard Dr.

W.

Reed Johnson Janice E. Kerr, Esq.

Dr. Jerry Kline Mr. John Marrs Thomas S. Moore, Esq.

Bruce Norton, Esq.

Joel R. Reynolds, Esq.

Mr. James

0. Schuyler Mr. Gordon Silver Michael J. Strumwasser, Esq.

Paul C. Yalentine, Esq.

Harry M. Willis John F. Wolf, Esq Atomic Safety and Licensing Board Panel Atomic Safety and Licensing Appeal Panel Mr.. Malcolm H. Furbush Resident Inspector/Diablo Canyon NPS Dr. William E.

Cooper Mr.

W.

C. Gangloff Mr.

Owen H. Davis Dr. Jose Roesset ACRS Members Dr. Robert C. Axtmann Mr. Myer Bender Dr.

Max W. Carbon Mr. Jesse C. Ebersole Mr. Harold Etherington Dr. William Kerr Dr. Harold W. Lewis Dr. J.

Carson Mark Mr. William M. Mathis

. Dr.

Dade W. Moeller Dr. David Okrent Dr. Milton S. Plesset Mr. Jeremiah J.

Ray Dr. Paul C.

Shewmon Dr. Chester P. Siess Mr. David A. Ward