ML16341B088

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 6, Table 6.2-3 Boron Injection Tank Design Parameters. Page 1 of 1
ML16341B088
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16341B088 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

6.2-3 Page:

1 of 1 BORON INJECTION TANK DESIGN PARAMETERS Number 1 per unit Total Volume, gal (also useable volume) 900 Boron concentration, (ppm) 0 to 2600 Design pressure, psig 2735 Design temperature, ºF 300 Operating pressure, psig (Injection Mode) 2340 Operating pressure, psig (Standby) atmospheric Operating temperature, ºF ambient Material SS Clad Carbon Steel Code ASME B&PV Code Section III Class C