ML16341B087

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 6, Table 6.2-2 - Accumulator Design Parameters. Page 1 of 1
ML16341B087
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16341B087 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

6.2-2 Page:

1 of 1 ACCUMULATOR DESIGN PARAMETERS Number 4 per unit Type Stainless steel clad / carbon steel Design pressure, psig 700 Design temperature, ºF 300 Operating temperature, ºF 120 Normal pressure, psig 621.5 Minimum pressure, psig 585.0 Total volume, ft3 1350 Maximum water volume at operating conditions, ft3 971 Minimum water volume at operating conditions, ft3 921 Boron concentration (as boric acid), ppm 2400 to 2600 Code ASME B&PV Code Section III Class C