IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
16.1 Table:
6.2-2 Page:
1 of 1 ACCUMULATOR DESIGN PARAMETERS Number 4 per unit Type Stainless steel clad / carbon steel Design pressure, psig 700 Design temperature, ºF 300 Operating temperature, ºF 120 Normal pressure, psig 621.5 Minimum pressure, psig 585.0 Total volume, ft3 1350 Maximum water volume at operating conditions, ft3 971 Minimum water volume at operating conditions, ft3 921 Boron concentration (as boric acid), ppm 2400 to 2600 Code ASME B&PV Code Section III Class C