INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 24.0 Table:
5.8-1 Page:
1 of 2 CONTAINMENT REGIONAL DESIGNATION / IGNITER ASSEMBLY LOCATIONS UNIT 1 TRAIN 'A' TRAIN 'B' Region Compartment/Area No.
Region Compartment/Area-Elevation No.
1 Upper Volume Dome Area - 760' A-13 1
Upper Volume Dome Area - 760' B-13 1
Upper Volume Dome Area - 760' A-14 1
Upper Volume Dome Area - 760' B-14 1
Upper Volume Dome Area - 760' A-15 1
Upper Volume Dome Area - 760' B-15 2
Upper Volume Dome Area - 748' A-16 2
Upper Volume Dome Area - 748' B-16 2
Upper Volume Dome Area - 748' A-17 2
Upper Volume Dome Area - 748' B-17 2
Upper Volume Dome Area - 748' A-18 2
Upper Volume Dome Area - 748' B-18 3
Ice Cond. Upper Plenum 709' A-1 3
Ice Cond. Upper Plenum 709' B-1 3
Ice Cond. Upper Plenum 709' A-2 3
Ice Cond. Upper Plenum 709' B-2 4
Ice Cond. Upper Plenum 709' A-3 4
Ice Cond. Upper Plenum 709' B-3 4
Ice Cond. Upper Plenum 709' A-4 4
Ice Cond. Upper Plenum 709' B-4 4
Ice Cond. Upper Plenum 709' A-5 4
Ice Cond. Upper Plenum 709' B-5 5
Ice Cond. Upper Plenum 709' A-6 5
Ice Cond. Upper Plenum 709' B-6 5
Ice Cond. Upper Plenum 709' A-7 5
Ice Cond. Upper Plenum 709' B-7 6
Outside #2 SG Enclosure 662' A-12 6
Outside #2 SG Enclosure 659' B-12 6
Outside #3 SG Enclosure 662' A-11 6
Outside #3 SG Enclosure 659' B-11 7
Outside #1 SG Enclosure 662' A-8 7
Outside #1 SG Enclosure 659' B-8 7
Outside #4 SG Enclosure 662' A-9 7
Outside #4 SG Enclosure 659' B-9 7
Outside PRZ Enclosure 662' A-10 7
Outside PRZ Enclosure 659' B-10 8
East Fan/Accumulator Room 635' A-25 8
East Fan/Accumulator Room 630' B-25 8
East Fan/Accumulator Room 632' A-26 8
East Fan/Accumulator Room 634' B-26 9
West Fan/Accumulator Room 632' A-27 9
West Fan/Accumulator Room 634' B-27 9
West Fan/Accumulator Room 634' A-28 9
West Fan/Accumulator Room 634' B-28 10 Instrument Room 623' A-35 10 Instrument Room 630' B-35 11 Primary Shield Wall 643' A-19 11 Primary Shield Wall 646' B-19 11 Primary Shield Wall 640' A-20 11 Primary Shield Wall 646' B-20 11 Primary Shield Wall 644' A-21 11 Primary Shield Wall 648' B-21 11 Primary Shield Wall 641' A-22 11 Primary Shield Wall 648' B-22 11 Primary Shield Wall 642' A-23 11 Primary Shield Wall 646' B-23
INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 24.0 Table:
5.8-1 Page:
2 of 2 CONTAINMENT REGIONAL DESIGNATION / IGNITER ASSEMBLY LOCATIONS UNIT 1 TRAIN 'A' TRAIN 'B' Region Compartment/Area No.
Region Compartment/Area-Elevation No.
11 Primary Shield Wall 642' A-24 11 Primary Shield Wall 646' B-24 12 Inside #1 SG Enclosure 689' A-30 12 Inside #1 SG Enclosure 689' B-30 13 Inside #2 SG Enclosure 689' A-34 13 Inside #2 SG Enclosure 689' B-34 14 Inside #3 SG Enclosure 689' A-33 14 Inside #3 SG Enclosure 689' B-33 15 Inside #4 SG Enclosure 689' A-31 15 Inside #4 SG Enclosure 689' B-31 16 Inside PRZ Enclosure 689' A-32 16 Inside PRZ Enclosure 687' B-32 17 Vicinity PRT-618' A-29 17 Vicinity of PRT-618' B-29 KEY SG - Steam Generator PZR - Pressurizer PRT - Pressurizer Relief tank Note: The locations given are for Cook Nuclear Plant Unit 1. For similar locations, in some cases the igniter assembly identification numbers are different, between Unit 1 and Unit 2.