IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.3.4-1 Page:
1 of 1 ICE CONDENSER ALLOWABLE LIMITS(1)
Elastic Analysis Load Combination Mechanical(3)
Mechanical & Thermal Fatigue Limit Analysis (Load Factors)(2)
Test (Load Factors)
D + OBE S(44) 3S AISC-69 Part I 1.7 1.87 D + DBA 1.33 S N/A N/A 1.3 1.43 D + DBE 1.33 S N/A N/A 1.3 1.43 D + DBE +
DBA 1.65 S N/A N/A 1.18 1.3 1 For particular components that do not meet these limits specific justification shall be provided on a case by case basis.
2 For mechanical loads only. Mechanical plus thermal expansion, combination and fatigue shall satisfy the elastic analysis limits.
3 Membrane (direct) stresses shall be less than or equal to 0.7 Su (70% of ultimate stress).
4 S = Allowable stresses as defined in Sections 1.5 and 1.6 of the AISC-69 Part I Specification.