Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.3.2-1 Page:
1 of 2 ICE CONDENSER DESIGN PARAMETERS Reactor Containment Volume (net free volume)
Upper Compartment, ft3 745,896 Ice Condenser, ft3 126,940 Lower Compartment (active), ft3 306,800 Total Active Volume, ft3 1,179,636 Lower Compartment (dead-ended), ft3 61,702 Total Containment volume, ft3 1,241,338 Reactor Containment Air Compression Ratio1 1.41 Reactor power, MWt (design basis) 3391 Design Energy Release to Containment Initial blowdown mass release, lb 549,000 Initial blowdown energy release, Btu 346.7 x 106 Allowance for undefined energy release in addition to core residual heat, Btu 50 x 106 Ice Condenser parameters Required weight of ice in condenser, lb REFER TO TECHNICAL SPECIFICATIONS Dimensions of ice condenser O.D., ft 115 I.D., ft.
89 Average Arc length, ft 267 Width (less insulation panels), ft 11 Ice bed height, ft 48 Inlet door flow area, ft2 1000 Ice condenser flow area, ft2 1326 Ice Condenser inlet door opening pressure, lb/ft2 1/2 to 1.0 Ice boron concentration, ppm boron 1800-2300 Refrigeration cooling capacity (current as of 1/82) 1 Defined in Section 14.3.
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.3.2-1 Page:
2 of 2 ICE CONDENSER DESIGN PARAMETERS Installed cooling capacity for compartment, Tons 75 Maximum compartment heat input, Tons (per unit) 35 Total cooling capacity for plant, Tons (capacity shared by two units) 250