OtlT 6 1982 Dr. William E. Cooper IDVP Project Hanager Teledyne Engineering Services 130 Second Avenue Waltham, tlassachusetts 02254

Dear Dr. Cooper:

Dis ution:

Docu)ent=Control: 50-275/323 NRC PDR L PDR NSIC PRC System LB//3 File DEisenhQt/RPurpl e TNovak JKerr igan HSchierling JLee LChandler, OELD I&E ACRS (16)

HRDenton At the NRC meeting with you and Pacific Gas and Electric Company on September 1,

1982 we discussed the requirement to assess the basic cause of design errors in accordance with the Commission Order and the NRR letter of November 19, 1981.

He request that you, as the manager of the

IDYP, prepare such an assessment and include it in your IDVP final reports for Phase I and Phase II.

Sincerely, cc:

See next page Original slgnel bg 5)arrell G. Eisenhut Darrell G. Eisenhut, Director Division of Licensing 82ii03042i 82i006 j

l PDR ADOCK 05000275 P

PDR OFFICE J)

SURNAME/

DATE P DL:LB)3, Schierli

.p 8L..5.J.82...

DL:

3

~

~i~ ~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~

82 TN

~ ~

~ 0 ~ ~ ~ ~ ) ~ 0 ~ 0 ~ 0 ~ 0 ~ ~ ~ ~ ~ ~

/7 7/ /82

~ ~ ~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~

~ I P ~

D'e (Gi

~ ~ ~ ~ ~ 0 ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

/82 NRC FORM 318 (10-80) NRCM 0240 OFF I CIA L R EGO R D COPY USGPO: 1981~i980

0 r.

0 PDiab>o Canyon Mr. Malcolm H. Furbush Vice President - General Counsel Pacific Gas 5 Electric Company P. 0.

Box 7442 San Francisco, California 94120 CC:

Philip A. Crane, Jr.,

Esq.

Pacific Gas

& Electric Company P. 0.

Box 7442 San Francisco, California 94120 Janice E. Kerr, Esq.

California Public Utilities Commission 350 McAllister Street San Francisco, California 94102 Mr. Frederi ck Ei ssl er, Pr esi dent Scenic Shoreline Preservation Conference, Inc.

4623 More Mesa Drive Santa Barbara, California, 93105 Ms. Elizabeth Apfelberg 1415 Cozadero San Luis Obispo, CA 93401 Mr. 'Gordon A. Silver Ms. Sandra A. Silver 1760 Alisal Street San Luis Obispo, CA 93401 Harry M. Willis, Esq.

Seymour 5 Willis

601 California Street, Suite 2100 San Francisco, CA 94108 Mr. Richard Hubbard MHB Technical Associates Suite K

1725 Hamilton Avenue San Jose, CA 96125 Mr. John Marrs, Managing Editor San Luis Obispo County Telegram Tribune 1321 Johnson Avenue P.

O.Box 112 San Luis Obispo, CA 93406 Resident Inspector/Diablo Canyon NPS c/o U. S. Nuclear Regulatory Commission P. 0.

Box 369 Avila Beach, California 93424 Ms.

Raye Fleming 1920 Matti e Road Shell Beach, California 93440 Joel

Reynolds, Esq.

John R. Phillips, Esq.

Center for Law in the Public Interest 10951 West Pico Boulevard Third Floor Los Angeles, California 90064 Paul C. Valentine, Esq.

321 Lytton Avenue Palo Alto, California 94302 Mr. Byron S.

Georgiou Legal Affairs Secretary Governor's Office State Capitol Sacramento, California 95814 Herbert H. Brown, Esq.

Hill, Christopher 8 Phillips, P.C.

1.900 M Street, N.W.

Washington, D..

C.

20036 Mr. Dick Blankenburg Editor 8 Co-Publisher South County Publishing Company P.

0 ~

Box 460 Arroyo Grande, California 93420 Mr. James

0. Schuyler Vice President - Nuclear Generation Department Pacific Gas 8 Electric Company P. 0.

Box 7442 San Francisco, California 94120

,It

Mr. Malcolm H. Furbush Bruce Norton, Esq.

Suite 202 3216 North 3rd Street Phoenix, Arizona 85012 Mr.

W.

C. Gangloff Westinghouse Electric Corporation P. 0.

Box 355 Pittsburg, Pennsylvania 15230 David F. Fleischaker, Esq.

P. 0.

Box 1178 Oklahoma City, Oklahoma 73101 Arthur C. Gehr, Esq.

Snell 8 Wilmer 3100 Valley Center

Phoenix, Arizona 85073 Mr.

Owen H. Davis, Director Federal Agency Relations Pacific Gas and Electric Company 1050 17th Street, N.W.

Suite 1180 Washington, D.

C.

20036 Regional Administrator - Region V

U.S;.Nuclear Regulatory Cormission 1450 Maria Lane Suite 210 Walnut Creek, Cali fornia

'='4596

~

g ry