IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

21 Table:

4.3-2 Page:

1 of 1

SUMMARY

OF ESTIMATED CUMULATIVE FATIGUE USAGE FACTORS FOR COMPONENTS OF THE REACTOR VESSEL (UNIT 1)1 Usage Factor 2 and 3 Item Original Rerated Control Rod Housing

.06 0.81 Head Flange

.015 0.185 Vessel Flange

.005 0.092 Stud Bolts

.310 0.449 Primary Nozzles Inlet 0.020

.098 Primary Nozzles Outlet 0.028

.063 Core Support Pad (lateral) 0.015

.693 Bottom Head to Shell 0.003

.018 Bottom Instrumentation 0.142

.122 Vessel Wall Transition 0.002

.007 1 The usage factors for Unit 2 are available in the Unit 2 Stress Report.

2 Covers all transients.

3 As defined in Section III of the ASME Boiler and Pressure Vessel Code, Nuclear Vessels.