ML16340A108

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 4, Table 4.2-2, Reactor Coolant Water Chemistry Specification
ML16340A108
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16340A108 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

4.2-2 Page:

1 of 1 REACTOR COOLANT WATER CHEMISTRY SPECIFICATION Electrical Conductivity Determined by the concentration of boric acid and alkali present. Expected range is 1 to 40 µMhos/cm at 25ºC.

Solution pH Determined by the concentration of boric acid and alkali present. Expected values range between 4.2 (high boric acid concentration) to 10.5 (low boric acid concentration) at 25ºC.

Oxygen, ppm, max.

0.10 Chloride, ppm, max 0.15 Fluoride, ppm, max.

0.15 Hydrogen, cc (STP)/kg H20 25 - 50 Total Suspended Solids, ppm, max.

1.0 pH Control Agent (Li7OH)

Reactor coolant pH is controlled during power operation by adjusting lithium as a function of the coolant boron concentration.

Boric Acid as ppm B Variable from 0 to 4000