Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
4.2-2 Page:
1 of 1 REACTOR COOLANT WATER CHEMISTRY SPECIFICATION Electrical Conductivity Determined by the concentration of boric acid and alkali present. Expected range is 1 to 40 µMhos/cm at 25ºC.
Solution pH Determined by the concentration of boric acid and alkali present. Expected values range between 4.2 (high boric acid concentration) to 10.5 (low boric acid concentration) at 25ºC.
Oxygen, ppm, max.
0.10 Chloride, ppm, max 0.15 Fluoride, ppm, max.
0.15 Hydrogen, cc (STP)/kg H20 25 - 50 Total Suspended Solids, ppm, max.
1.0 pH Control Agent (Li7OH)
Reactor coolant pH is controlled during power operation by adjusting lithium as a function of the coolant boron concentration.
Boric Acid as ppm B Variable from 0 to 4000