ML16340A099
Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
18 Table:
4.1-5 Page:
1 of 2 STEAM GENERATOR DESIGN DATA Unit 1 Unit 2 Number of Steam Generators 4
4 Design Pressure, Reactor Coolant/Steam, psig 2485/1085 2485/1085 Reactor Coolant Hydrostatic Test Pressure(tube side-cold), psig 3106 3107 Design temperature, Reactor Coolant/Steam, °F 650/600 650/600 Reactor Coolant Flow, lb/hr x 106 33.91 38.22 33.7 Total Heat Transfer Surface Area, ft2 54,927 54,500 Rated Thermal Output/MWt) 816 852.75 Operating Parameters at 100% Load Primary Side:
Heat Transfer Rate (per unit), Btu/hr x 106 27733 30704 2910 Coolant Inlet Temperature, °F 582.3 - 616.9 606.4 Coolant Outlet Temperature, °F 511.7 - 549.3 541.3 Flow Rate, (per unit), lb/hr x 106 33.9 (1) 3.82 (2) 33.7 Pressure loss, psi.
32.05 26.1 Secondary Side:
Steam Temperature at full power, °F 481.8 - 521 521.1 Steam Flow, lb/hr x 106 3.53 (3) 3.9 (4) 3.685 Steam Pressure at full power, psia 575.8 - 819.7 820 Maximum moisture carryover, wt %
0.045 0.15 Feedwater Temperature 440 @ nozzle 431.3 @ #6 Heater Outlet Fouling Factor, hr-ft2 °F/Btu 0.00005 0.00005 Overall Height, ft-in 67 - 7.25 67-8 Shell OD, upper/lower, in 175.75/135 175.9/135 Number of U-tubes 3496 3592 U-tube outer Diameter, in 0.875 0.875
- Quantities are for each steam generator.
1 RCS flow rate based on Thermal Design Flow of 88500 gpm at 536°F.
2 RCS flow rate based upon Mechanical Design Flow of 99700 gpm at 535°F.
3 Heat transfer rate and steam flow for 816 MWt per steam generator.
4 Heat transfer rate and steam flow for 900 MWt per steam generator.
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
18 Table:
4.1-5 Page:
2 of 2 STEAM GENERATOR DESIGN DATA Tube Wall Thickness, (minimum), in 0.044 0.050 Number of manways/ID, in 2/18 2/16 4/16 Number of handholes/ID, in 6/6 6/6 Number of inspection ports/ID, in 2/6 2/4 Unit 1 Rated Load No Load Reactor Coolant Water Volume, ft3 1141.15 1141.1 (5)
Primary Side Fluid Heat Content, Btu x 106 29.86 29.27 Secondary Side Water Volume, ft3 20358 3235 Secondary Side Steam Volume, ft3 3583 (8) 2315 Secondary Side Fluid Heat Content, Btu x 107 5.69 (8) 8.789 Unit 2 Rated Load No Load Reactor Coolant Water Volume,** ft3 1112 1112 Primary Side Fluid Heat Content, Btu 29.0 x 106 28.46 x 106 Secondary Side Water Volume, ft3 2077 3351 Secondary Side Steam Volume, ft3 3589 2315 Secondary Side Fluid Heat Content, Btu 5.18 x 107 8.44 x 107
- Quantities are for each steam generator.
Values may change subject to steam generator tube plugging.
5 Hot condition @ power. Volume at ambient temperature is approximately 1130 ft. 3.
6 Based upon hot volume and primary fluid @ 567.8°F and pressure of 2250 psia.
7 Based upon hot volume and primary fluid @547°F and pressure of 2250 psia.
8 Based upon secondary side fluid @ 515.2°F (saturated conditions).
9 Based upon secondary side fluid @ 547°F (saturated conditions).