IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
16.4 Table:
3.4-4 Page:
1 of 2 Unit 2 COMPARISON OF THINC-IV AND THINC-I PREDICTIONS WITH DATA FROM REPRESENTATIVE WESTINGHOUSE TWO AND THREE LOOP REACTORS Reactor Power (MWt)
% Full Power Measured Inlet Temp (oF) rms(oF )
THINC-I (oF )
THINC-IV Improvement (oF) for THINC-IV over THINC-I Ginna 847 65.1 543.7 1.97 1.83 0.14 854 65.7 544.9 1.56 1.46 0.10 857 65.9 543.9 1.97 1.82 0.15 947 72.9 543.8 1.92 1.74 0.18 961 74.0 543.7 1.97 1.79 0.18 1091 83.9 542.5 1.73 1.54 0.19 1268 97.5 542.0 2.35 2.11 0.24 1284 98.8 540.2 2.69 2.47 0.22 1284 98.9 541.0 2.42 2.17 0.25 1287 99.0 544.4 2.26 1.97 0.29 1294 99.5 540.8 2.20 1.91 0.29 1295 99.6 542.0 2.10 1.83 0.27 Robinson 1427.0 65.1 548.0 1.85 1.88 0.03 1422.6 64.9 549.4 1.39 1.39 0.00
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
16.4 Table:
3.4-4 Page:
2 of 2 Unit 2 COMPARISON OF THINC-IV AND THINC-I PREDICTIONS WITH DATA FROM REPRESENTATIVE WESTINGHOUSE TWO AND THREE LOOP REACTORS Reactor Power (MWt)
% Full Power Measured Inlet Temp (oF) rms(oF )
THINC-I (oF )
THINC-IV Improvement (oF) for THINC-IV over THINC-I 1529.0 88.0 550.0 2.35 2.34 0.01 2207.3 100.7 534.0 2.41 2.41 0.00 2213.9 101.0 533.8 2.52 2.44 0.08