Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

19.1 Table:

3.3-6 Page:

1 of 1 Unit 2 COMPARISON OF MEASURED AND CALCULATED DOPPLER DEFECTS Plant Fuel Type Core Burnup (MWD/MTU)

Measured (pcm)1 Calculated (pcm) 1 Air-filled 1800 1700 1710 2

Air-filled 7700 1300 1440 3

Air and helium-filled 8460 1200 1210 1 1 pcm = 10-5