IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 16.4 Table:
3.1-3 Page:
1 of 1 Unit 2 DESIGN LOADING CONDITIONS FOR REACTOR CORE COMPONENTS 1.
Fuel Assembly Weight 2.
Fuel Assembly Spring Forces 3.
Internals Weight 4.
Control Rod Trip (equivalent static load) 5.
Differential Pressure 6.
Spring Preloads 7.
Coolant Flow Forces (static) 8.
Temperature Gradients 9.
Differences In Thermal Expansion
- a. Due to temperature differences
- b. Due to expansion of different materials 10.
Interference Between Components 11.
Vibration (mechanically or hydraulically induced) 12.
One Or More Loops Out Of Service 13.
Operational Transients 14.
Pump Overspeed 15.
Seismic Loads (operating basis earthquake and design basis earthquake) 16.
Blowdown Forces (due to cold and hot leg break)