IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

19.1 Table:

2.6-6 Page:

1 of 3 ESTIMATES (IN MILLIONS) OF ANNUAL ENTRAINMENT LOSSES OF FISH LARVAE AND FISH AT THE D.C.

COOK NUCLEAR PLANT, SOUTHEASTERN LAKE MICHIGAN, 1975 - 1982.

CALCULATIONS USE ACTUAL REPORTED FLOW RATES OF THE CIRCULATING WATER SYSTEM YEAR OF ESTIMATE Taxon 1975 1976 1977 1978 1979 1980 1981 1982 Total

% Total Alewife 63.708 53.7550 27.3888 31.098 125.6180 49.35 111.54 92.425 554.8828 74.34 Spottail shiner 3.41 0.9361 2.760 1.681 1.8228 21.06 7.257 28.2297 67.1566 9.00 Rainbow smelt 1.3608 0.4145 0.1795 0.3496 0.3726 11.954 2.6265 18.5233 35.7808 4.79 Yellow perch 0.17554 0.03807 1.3224 3.0655 0.3840 0.8971 2.506 4.9700 13.3586 1.79 Trout-perch 1.079 0.2509 0.1456 0.0194 0.6288 0.4858 0.5394 1.3749 4.5238 0.61 Johnny darter 0.0440 0.210 0.707 0.772 0.8105 0.153 0.7046 3.4011 0.46 Slimy sculpin 0.2431 0.06092 0.0256 0.130 0.553 1.002 0.4887 2.5033 0.34 Mottled sculpin 0.152 0.146 0.0483 0.131 0 143 0.4870 1.1073 0.15 Common carp 0.0912 0.0235

0. 175 0.3603 0.0513 0 187 0.8883 0.12 Ninespine stickleback 0.124 0.379 0.156 0.0112 0.6702 0.09 Quillback 0.0628 0.534 0.5968 0.08

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

19.1 Table:

2.6-6 Page:

2 of 3 ESTIMATES (IN MILLIONS) OF ANNUAL ENTRAINMENT LOSSES OF FISH LARVAE AND FISH AT THE D.C.

COOK NUCLEAR PLANT, SOUTHEASTERN LAKE MICHIGAN, 1975 - 1982.

CALCULATIONS USE ACTUAL REPORTED FLOW RATES OF THE CIRCULATING WATER SYSTEM YEAR OF ESTIMATE Taxon 1975 1976 1977 1978 1979 1980 1981 1982 Total

% Total Burbot 0.0202 0.102 0.3428 0.4650 0.06 Deepwater sculpin 0.178 0.0141 0.1921 0.03 Unidentified sculpins 0.1899 0.0892 0.0918 0.175 0.0905 0.607 0.5953 0.5744 2.4731 0.33 Unidentified minnows 0.1248 0.8138 0.2846 0.1714 1.0280 2.4226 0.32 Unidentified coregonines 0.0850 0.0850 0.01 Unidentified darters 0.0276 0.0276

<0.01 Poor condition 0.555 2.8642 0.4274 3.352 5.9935 6.4765 11.859 17.9458 55.4734 7.43 Unidentified larvae 0.1693 0.0349 0.0887 0.100 0.3929 0.05 Total larvae 77.08664 58.91119 33.5088 41.3215 137.0399 92.1583 139.2696 167.1054 746.4013 Total eggs 743.1879 2,269.4543 1,320.301 5,840.8138 1,392.5408 3,334.692 995.94 7,005.26 22,902.1898

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

19.1 Table:

2.6-6 Page:

3 of 3 ESTIMATES (IN MILLIONS) OF ANNUAL ENTRAINMENT LOSSES OF FISH LARVAE AND FISH AT THE D.C.

COOK NUCLEAR PLANT, SOUTHEASTERN LAKE MICHIGAN, 1975 - 1982.

CALCULATIONS USE ACTUAL REPORTED FLOW RATES OF THE CIRCULATING WATER SYSTEM YEAR OF ESTIMATE Taxon 1975 1976 1977 1978 1979 1980 1981 1982 Total

% Total Total Cook Plant Flow (millions of m 3) 1,298 1,292 1,138 2,370 2,476 2,830 2,753 2,749.