IR 05000602/2016201
| ML16326A446 | |
| Person / Time | |
|---|---|
| Site: | University of Texas at Austin |
| Issue date: | 12/05/2016 |
| From: | Anthony Mendiola Research and Test Reactors Oversight Branch |
| To: | Biegalski S University of Texas at Austin |
| Morlang G | |
| References | |
| IR 2016201 | |
| Download: ML16326A446 (17) | |
Text
December 5, 2016
SUBJECT:
UNIVERSITY OF TEXAS AT AUSTIN - NUCLEAR REGULATORY COMMISSION ROUTINE INSPECTION REPORT NO. 50-602/2016-201
Dear Dr. Biegalski:
From October 31 - November 3, 2016, the U.S. Nuclear Regulatory Commission (NRC or the Commission) completed an inspection at the University of Texas at Austin Nuclear Engineering Teaching Laboratory facility. The enclosed report documents the inspection results, which were discussed on November 3, 2016, with you and Paul Whaley, Associate Director, The University of Texas Nuclear Engineering Teaching Laboratory; and members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed various activities, and interviewed personnel.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Gary Morlang at (301) 415-4092 or by electronic mail at Gary.Morlang@nrc.gov.
Sincerely,
/RA/
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-602 License No. R-129
Enclosure:
As stated
cc: See next page
University of Texas at Austin Docket No. 50-602
cc:
Governors Budget and Policy Office PO Box 12428 Austin, Texas 78711-2428
Bureau of Radiation Control State of Texas 1100 West 49th Street Austin, TX 78756
Dr. Gregory L. Fenves The University of Texas at Austin Office of the President 110 Inner Campus Drive, G3400 Austin, TX 78712-3400
Maurie McInnis Executive Vice President and Provost The University of Texas at Austin 1 University Station, G1000 Austin, TX 78712
Roger Mulder Office of the Governor P.O. Box 12428 Austin, TX 78711
Mr. Paul Whaley, Associate Director Nuclear Engineering Teaching Laboratory The University of Texas at Austin 10100 Burnet Road, Building 159 Austin, TX 78613
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
Michael Krause, Reactor Supervisor The University of Texas at Austin 1 University Station, R9000 Austin, TX 78712
ML16326A446; *concurrence via e-mail NRC-002 OFFICE NRR/DPR/PROB*
NRR/DPR/PROB/LA*
NRR/DPR/PROB/BC NAME GMorlang NParker AMendiola DATE 11/22/2016 11/23/2016 12/5/2016
U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION
Docket No.
50-602
License No.
R-129
Report No.
50-602/2016-201
Licensee:
The University of Texas at Austin
Facility:
Nuclear Engineering Teaching Laboratory
Location:
Pickle Research Campus, Building 159
10100 Burnet Road Austin, TX 78758
Dates:
October 31 - November 3, 2016
Inspector:
Gary Morlang
Approved by:
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
EXECUTIVE SUMMARY
The University of Texas at Austin Nuclear Engineering Teaching Laboratory Report No. 50-602/2016-201
The primary focus of this routine, announced inspection included onsite review of selected aspects of the University of Texas at Austin (the licensees) Nuclear Engineering Teaching Laboratory TRIGA Mark II research reactor safety program including: (1) organizational structure and staffing, (2) operations logs and records, (3) operator requalification, (4) surveillance testing and limiting conditions for operation, (5) emergency preparedness, (6) maintenance, and (7) fuel handling, since the last Nuclear Regulatory Commission (NRC)
inspection in these areas. The licensees program was acceptably directed toward the protection of public health and safety and was in compliance with NRC requirements.
Organizational Structure and Staffing
- The organizational structure, functions, and staffing were consistent with Technical Specification (TS) requirements. Staff qualifications satisfied TS requirements.
Operations Logs and Records
Reactor operations and logs were being maintained acceptably and operations were carried out in accordance with procedural and TS requirements.
Operator Requalification
The operator requalification program was up-to-date and being acceptably maintained.
Medical examinations were being completed biennially as required.
Surveillance Testing and Limiting Conditions for Operation
- The program for surveillance testing, including checks, tests, and calibration of equipment, was being implemented in accordance with requirements specified in Sections 3 and 4 of the TS.
The emergency plan and implementing procedures were being audited and reviewed biennially as required.
Letters of agreements documenting emergency support to be provided by offsite agencies needed to be updated as required. Inspector Follow-Up Item 05-602/2016-201-01.
Annual drills were being held and documentation was maintained concerning the follow-up critiques and subsequent corrective actions taken as needed.
- 2 -
Emergency preparedness training for staff personnel was being conducted as stipulated in the emergency plan.
Maintenance
- The facility maintenance program was being implemented as required by facility procedures.
Fuel Handling
Reactor fuel movements and fuel inspections were made and documented in accordance with procedure.
Fuel elements were being inspected on a biennial basis as required by the TS.
Enclosure REPORT DETAILS
Summary of Facility Status
The University of Texas at Austin (UT or the licensees) 1.1 megawatt TRIGA Mark II research reactor continued routine operations. The reactor is operated in support of laboratory experiments, maintenance and surveillance testing, and operator training. During the inspection, the reactor was operated to support sample irradiations and facility tours.
1.
Organizational Structure and Staffing
a.
Inspection Scope (Inspection Procedure (IP) 69001)
The inspector reviewed the following regarding the licensees organizational structure and functions to ensure that the requirements of Section 6.0 of licensees Technical Specification (TS) were being met:
- Management responsibilities and administrative controls
The UT Nuclear Engineering Teaching Laboratory (NETL) organizational structure and staffing
Administrative controls outlined in NETL Procedure No. ADMN-3, Personnel and Operator Qualifications, Revision (Rev. 0), approval dated January 31, 1992
UT, NETL, 2015 Annual Report, submitted March 31, 2016
American National Standards Institute/American Nuclear Society (ANSI/ANS)
Standard-15.4-1988, Selection and Training of Personnel for Research Reactors, dated June 9, 1988, and reaffirmed July 12, 1999
b.
Observations and Findings
Organization, structure, responsibilities, and staffing were as required by TS Section 6.1. Through review of various records and discussions with personnel, the inspector determined that the NETL staff satisfied the TS requirements and conformed to those outlined in ANSI/ANS-15.4-1998.
Four changes to senior management level personnel had occurred between March and August of 2016. As required by TS these changes were reported to the NRC.
c.
Conclusion
The organizational structure, functions, and staffing were consistent with TS requirements. Staff qualifications satisfied TS requirements.
- 2 -
2.
Operations Logs and Records
a.
Inspection Scope (IP 69001)
The inspector reviewed selected aspects of the following to verify operation of the reactor in accordance with TS Sections 3 through 5 and TS Section 6.1.3:
- TS through Amendment 4, dated May 10, 2001
Maintenance log for 2015 through the present
Selected monthly checklists for 2015 through the present
Selected prestart check sheets for 2015 through the present
Selected UT-TRIGA instrumentation and control system (ICS) console operation log sheets for 2015 and 2016
Selected startup-shutdown check sheets and the associated experiment startup-shutdown check sheets and heat exchanger startup-shutdown check sheets for 2015 through the present
Scram log sheets and startup reactivity calculation records from January 2015 to the present
NETL Operation Procedure, OPER-1, Startup - Shutdown Checks, Version (Ver.) 1.00, approved April 3, 2002
NETL Operation Procedure, OPER-2, Reactor Startup and Shutdown, Ver. 1.01, approved April 11, 2012,
NETL Operation Procedure, OPER-3, Reactor Operation Modes, Ver. 1.01, approved April 12, 2012
NETL Operation Procedure, OPER-4, Operation of Reactor Water Systems, Ver. 1.00, approved April 3, 2002
NETL Operation Procedure, OPER-5, Operation of Air Confinement System, Ver. 1.00, approved April 3, 2002
NETL Operation Procedure, OPER-6, Reactor Bay Systems, Ver. 1.00, approved April 3, 2002
UT, NETL, 2015 Annual Report, submitted March 31, 2016
b.
Observations and Findings
The inspector reviewed selected operations records from January 2015 through the present. These records included daily startup-shutdown checklists, log sheets, experiment startup and shutdown checklists, weekly checklists, monthly checklists, and other associated forms. Information on the operational status of the facility was recorded accurately on the log sheets and/or the checklists as required by procedure
The inspector observed the performance of the daily console startup checklist and a reactor startup to power.
Through interviews with operators and review of logs and records, the inspector confirmed that shift staffing met the minimum requirements for duty and on-call personnel as required by TS Section 6.1.3. This was noted on the log sheets by
- 3 -
listing the names of the individuals designated as the reactor operator and the senior reactor operator.
c.
Conclusion
Reactor operations and logs were being maintained acceptably and operations were conducted in accordance with procedural and TS requirements.
3.
Operator Requalification
a.
Inspection Scope (IP 69001)
To determine that operator requalification activities and training were conducted as required by the UT-TRIGA requalification plan and that medical requirements were met, the inspector reviewed:
Medical examination records for selected operators
Training lectures and records for the training cycle (2016-2017)
UT-TRIGA Requalification Plan, Rev. 1, dated November 1990
Logs and records of reactivity manipulations for the requalification cycle (2016-2017)
NETL Administrative Procedure, ADMN-3, Procedures for Personnel and Operator Qualifications, Rev. 0, approved January 31, 1992
b.
Observations and Findings
There were three qualified SROs and one qualified RO at the facility. A review of all of the operators licenses showed that they were current. The inspector also noted that there were two students who were in training.
A review of the logs and records showed that training was being conducted in accordance with the licensees requalification and training program. Records of quarterly reactor operations, reactivity manipulations, and operator activities indicating operator proficiency were being maintained. Documentation indicating the completion of semiannual change and procedure reviews by the operators and annual supervisory evaluations of the operators were also maintained.
Annual written examinations were being completed as required or credit was taken by the licensee for the licensed operator exams administered by the NRC to satisfy the requalification cycle exam requirements when applicable.
The inspector verified that operators were receiving the required biennial medical examinations as well.
- 4 -
c.
Conclusion
The requalification program was up-to-date and being acceptably maintained.
Medical examinations were being completed biennially as required.
4.
Surveillance Testing and Limiting Conditions for Operation
a.
Inspection Scope (IP 69001)
To determine that maintenance and surveillance activities and calibrations were being completed as required by TS Sections 3 and 4, the inspector reviewed:
- TS through Amendment 4, dated May 10, 2001
System maintenance log for 2015 through the present
Weekly-monthly surveillance log for 2015 through the present
Semiannual and annual surveillance log for 2015 through the present
Selected UT-TRIGA ICS console operation log sheets from January 2015 through the present
NETL Maintenance Procedure, MAIN-1, Interlock and SCRAM Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-2, Instrument System Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-3, Support System Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-6, Rod and Drive Maintenance, Inspection, Ver. 3.00, approved July 26, 2000
NETL Operation Procedure, OPER-6, Reactor Bay Systems, Ver. 1.00, approved April 4, 2002
NETL Surveillance Procedure, SURV-1, Fuel Temperature Calibration, Rev. 0, approved January 24, 1992
NETL Surveillance Procedure, SURV-2, Reactor Pool Power Calibration, Rev. 1, approved March 2, 2009
NETL Surveillance Procedure, SURV-3, Excess Reactivity and Shutdown Margin, Ver. 2.00, approved April 4, 2002
NETL Surveillance Procedure, SURV-4, Reactor Water Systems Surveillance, Rev. 1, approved January 22, 1991
NETL Surveillance Procedure, SURV-5, Air Confinement System Surveillance, Rev. 2, approved April 4, 2002
NETL Surveillance Procedure, SURV-6, Control Rod Calibration, Rev. 1, approved March 2, 2009
NETL Surveillance Procedure, SURV-7 Pulse Characteristic Comparison, Rev. 0, approved January 24, 1992
UT, NETL, 2015 Annual Report, submitted March 31, 2016
- 5 -
b.
Observations and Findings
The inspector reviewed selected surveillance procedures and records including the weekly-monthly and semiannual-annual surveillance logs. The inspector determined that selected weekly, monthly, semiannual, and annual checks, tests, and/or calibrations for TS required surveillances were completed as stipulated.
The tests and calibrations reviewed were completed on schedule and in accordance with licensee procedures. The appropriate records and logs reviewed were being maintained as required.
c.
Conclusion
The program for surveillance testing, including checks, tests, and calibration of equipment was being carried out in accordance with TS Section 3 and 4 requirements.
5.
a. Inspection Scope (IP 69001)
The inspector reviewed selected aspects of the following to verify compliance with the NETL emergency response plan:
- Emergency Plan (E-Plan), Rev. 3, dated December 10, 2009
Training records for the past 2 years
Emergency response facilities, supplies, equipment, and instrumentation
Documentation of emergency drills and exercises held during 2015
Letters of Agreement with support organizations including the Austin - Travis County Emergency Medical Services, City of Austin Fire Department, and the Brackenridge Hospital
NETL Administrative Procedure, ADMN-5, Protection Programs, Rev. 0, approved January 24, 1992
NETL Implementing Procedure, PLAN-0, Call and Notification, Ver. 2.00, approved November 9, 2000, with local permanent change (Emergency Call List) dated February 22, 2016
NETL Implementing Procedure, PLAN-E, Emergency Response, Ver. 3.00, approved November 2, 2006, which specified the emergency equipment and supplies required to be available at the facility
NETL Security Procedure, PLAN-S, Physical Security, Ver. 5.00, approved November 2, 2006
Emergency drill critique dated November 2015
b.
Observations and Findings
The E-Plan in use at the reactor and emergency facilities was the same as the version most recently submitted to the NRC for approval. The inspector verified that the E-Plan and implementing procedures were being audited and reviewed biennially as required and revised as needed. The inspector verified that
- 6 -
emergency response facilities, supplies, instrumentation, and equipment were being maintained and controlled as required in the E-Plan.
Through records review and interviews with licensee personnel, the inspector determined that emergency responders were knowledgeable of the proper actions to take in case of an emergency. Letters of agreement with outside response organizations had not been updated biennially as required. The licensee was informed that this issue would be handled as an Inspector Follow-up Item (IFI) for the next inspection (IFI 05-602/2016-201-01).
Emergency drills had been conducted annually as required by the E-Plan.
Records indicated that off-site support organizations had participated in the facility drills at least every 2 years as required. Critiques were held following the drills to discuss the strengths and weaknesses identified during the exercises and to develop possible solutions to any problems identified. The results of these critiques were documented. Emergency preparedness and response training for reactor staff personnel was being conducted and documented as stipulated in the E-Plan. The emergency call list was updated at least annually as stipulated in the E-Plan. The latest emergency call list was dated February 22, 2016.
c.
Conclusion
The emergency preparedness program was being conducted in accordance with the E-Plan.
6.
Maintenance
a.
Inspection Scope (IP 69001)
To determine that maintenance activities were being completed as required by TS and procedures, the inspector reviewed:
- TS through Amendment 4, dated May 10, 2001
System maintenance log for 2015 through the present
Weekly-monthly surveillance log for 2015 through the present
Semiannual and annual surveillance log for 2015 through the present
Selected UT-TRIGA ICS console operation log sheets from January 2015 through the present
NETL Maintenance Procedure, MAIN-1, Interlock and SCRAM Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-2, Instrument System Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-3, Support System Features, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-4, Area Radiation Monitors, Ver. 3.00, approved July 26, 2000
- 7 -
- NETL Maintenance Procedure, MAIN-5, Fuel Inspection and Measurement, Ver. 3.00, approved July 26, 2000
NETL Maintenance Procedure, MAIN-6, Rod and Drive Maintenance Inspection, Ver. 3.00, approved July 26, 2000
NETL Operation Procedure, OPER-6, Reactor Bay Systems, Ver. 1.00, approved April 4, 2002
NETL Surveillance Procedure, SURV-1, Fuel Temperature Calibration, Rev. 0, approved January 24, 1992
NETL Surveillance Procedure, SURV-2, Reactor Pool Power Calibration, Rev. 1, approved March 2, 2009
NETL Surveillance Procedure, SURV-3, Excess Reactivity and Shutdown Margin, Ver. 2.00, approved April 4, 2002
NETL Surveillance Procedure, SURV-4, Reactor Water Systems Surveillance, Rev. 1, approved January 22, 1991
NETL Surveillance Procedure, SURV-5, Air Confinement System Surveillance, Rev. 2, approved April 1, 2002
NETL Surveillance Procedure, SURV-6, Control Rod Calibration, Rev. 1, approved March 2, 2009
NETL Surveillance Procedure, SURV-7 Pulse Characteristic Comparison, Rev. 0, approved January 24, 1992
UT, NETL, 2015 Annual Report, submitted March 31, 2016
b.
Observations and Findings
The inspector reviewed selected maintenance procedures and maintenance records, including the system maintenance log. The log contained maintenance information on various systems, including the reactor coolant system, the radiation monitoring system, the ICS computer, the ICS data acquisition control system, the ICS neutron monitoring (power channel) system, and the ICS rod drive system. The logs and records showed that routine and preventive maintenance was controlled and documented in the maintenance and/or operations logs consistent with licensee procedures and within the time frame specified.
The leaking beam port bellows was replaced in November of 2015. The IFI for this major maintenance item will be closed. (IFI 05-602/2013-202-01).
- 8 -
c.
Conclusion
The licensees maintenance program was being implemented as required by NETL procedures.
7.
Fuel Handling and Movement
a.
Inspection Scope (IP 69001)
In order to verify adherence to fuel handling and inspection requirements specified in TS Sections 3.1.4, 4.1.4, 5.3, and 5.4, the inspector reviewed:
- Selected NETL pool configuration forms
UT-TRIGA Logbook 1 Fuel Movement Log and selected log sheets
Selected core arrangement forms and fuel pin inventory forms
Selected UT-TRIGA ICS console operation log sheets from January 2015 through the present
The NETL core configuration map on the control room wall, dated January 16, 2016
NETL Fuel Procedure, FUEL-1, Movement of Fuel, Ver. 1.00, approved February 17, 2005, with local permanent change Ver. 1.01, approved March 4, 2009, and associated forms
NETL Fuel Procedure, FUEL-2, Movement of Experiments, Rev. 0, approved July 30, 1991
NETL Maintenance Procedure, MAIN-5, Fuel Inspection and Measurement, Ver. 3.00, approved July 26, 2000
b.
Observations and Findings
The inspector determined that the licensee was maintaining the required records of the various fuel movements that had been completed. The inspector also determined that the fuel was being moved in compliance with procedure and the moves were being tracked and documented on the appropriate forms.
Following replacement of the leaking beam port bellows, the core was completely reloaded. One instrumented fuel element was replaced because of thermocouple failure in the element previously in that position.
The inspector also verified that the reactor fuel was being inspected biennially as required by TS Section 4.1.4. The most recent fuel inspection had been completed in January 2016.
- 9 -
c.
Conclusion
Reactor fuel movements and inspections were completed and documented in accordance with procedure and the fuel elements were being inspected biennially as specified by TS.
8.
Exit Meeting
The inspector presented the inspection results to members of licensee management at the conclusion of the inspection on November 3, 2016. The licensee acknowledged the findings presented. The licensee did not identify as proprietary any material reviewed as part of this inspection.
PARTIAL LIST OF PERSONS CONTACTED
Licensee Director, NETL T. Tipping Reactor Health Physicist and Laboratory Manager P. Whaley Associate Director, NETL G. Kline Senior Reactor Operator
INSPECTION PROCEDURE USED
IP 69001 Class II Non-Power Reactors
ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
50-602/2016-201-01 IFI Failure to update MOUs with outside support agencies
Closed
50-602/2013-202-01 IFI Beam Port Leak Repair
Discussed
None.
PARTIAL LIST OF ACRONYMS USED
American Nuclear Society ANSI
American National Standards Institute E-Plan
Instrumentation and Control System IP
Inspection Procedure IFI
Inspector Follow-up Item NETL
Nuclear Engineering Teaching Laboratory NRC
U.S. Nuclear Regulatory Commission Rev.
Revision RO
Reactor Operator ROC
Reactor Oversight Committee SRO
Senior Reactor Operator UT
University of Texas Ver.
Version