ML16293A120

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - (External_Sender) Byron Station Response to Maintenance & Testing Questions Regarding the Mitigating Strategies Final Integrated Plan
ML16293A120
Person / Time
Site: Byron  
Issue date: 10/18/2016
From: Zurawski L
Exelon Corp
To: John Hughey
Japan Lessons-Learned Division
References
Download: ML16293A120 (2)


Text

1 NRR-PMDAPEm Resource From:

Zurawski, Lisa M:(GenCo-Nuc) <lisa.zurawski@exeloncorp.com>

Sent:

Tuesday, October 18, 2016 5:31 PM To:

Hughey, John; Distel, David J:(GenCo-Nuc); Merkle, Donald:(GenCo-Nuc); Lynde, James M:(GenCo-Nuc)

Cc:

Spitzer, Douglas J:(GenCo-Nuc); Kuchenbecker, James P:(Contractor - GenCo-Nuc)

Subject:

[External_Sender] Response to question about FLEX equipment maintenance and testing.

Question: Is Byron using the EPRI report regarding FLEX maintenance and testing?

Response: The Preventative Maintenance (PM) and Testing Program for FLEX equipment was developed using existing procedures and processes ER-AA-200, Preventative Maintenance Program, and WC-AA-120, Preventative Maintenance PM Database Revision Requirements. The program satisfies NEI 12-06 section 11.5 by utilizing the following sources for maintenance and testing requirements:

A. Original Equipment Manufactures Recommendations B. Exelon Corporate PM Templates which were developed using INPO AP-913 process and Electric Power Research Institute Report 3002000623 entitled Nuclear Maintenance Applications Center: Preventive Maintenance Basis for FLEX Equipment.

C. Operating Experience D. Material Aging and Shelf Life (including consumables and fluids)

These requirements were applied to equipment which "directly performs FLEX mitigation strategy for core cooling, containment or spent fuel cooling" (NEI 12-06 11.5).

Any revisions to the scope or frequency of preventive maintenance or testing of FLEX equipment will be evaluated and authorized in accordance with ER-AA-200 and WC-AA-120.

Lisa Zurawski Byron Station Principal Regulatory Engineer 815-406-2991 Lisa.Zurawski@exeloncorp.com This Email message and any attachment may contain information that is proprietary, legally privileged, confidential and/or subject to copyright belonging to Exelon Corporation or its affiliates ("Exelon"). This Email is intended solely for the use of the person(s) to which it is addressed. If you are not an intended recipient, or the employee or agent responsible for delivery of this Email to the intended recipient(s), you are hereby notified that any dissemination, distribution or copying of this Email is strictly prohibited. If you have received this message in error, please immediately notify the sender and permanently delete this Email and any copies.

Exelon policies expressly prohibit employees from making defamatory or offensive statements and infringing any copyright or any other legal right by Email communication. Exelon will not accept any liability in respect of such communications. -EXCIP

Hearing Identifier:

NRR_PMDA Email Number:

3109 Mail Envelope Properties (DD36716564A86A4B8BFB3CA6B9EED3EFA8BD55A6)

Subject:

[External_Sender] Response to question about FLEX equipment maintenance and testing.

Sent Date:

10/18/2016 5:31:01 PM Received Date:

10/18/2016 5:31:37 PM From:

Zurawski, Lisa M:(GenCo-Nuc)

Created By:

lisa.zurawski@exeloncorp.com Recipients:

"Spitzer, Douglas J:(GenCo-Nuc)" <douglas.spitzer@exeloncorp.com>

Tracking Status: None "Kuchenbecker, James P:(Contractor - GenCo-Nuc)" <James.Kuchenbecker@exeloncorp.com>

Tracking Status: None "Hughey, John" <John.Hughey@nrc.gov>

Tracking Status: None "Distel, David J:(GenCo-Nuc)" <David.Distel@exeloncorp.com>

Tracking Status: None "Merkle, Donald:(GenCo-Nuc)" <Donald.Merkle@exeloncorp.com>

Tracking Status: None "Lynde, James M:(GenCo-Nuc)" <James.Lynde@exeloncorp.com>

Tracking Status: None Post Office:

exchm-ccc-21.exelonds.com Files Size Date & Time MESSAGE 2211 10/18/2016 5:31:37 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: