NRR E-mail Capture - McGuire Unit No. 2: Acceptance REVIEW- Relief Request Alternative Testing Approval for Two PORV Block Valves
ML16291A015
Person / Time
Site: Mcguire
Issue date: 10/13/2016
From: V Sreenivas
Plant Licensing Branch II
To: Capps S
Duke Energy Corp
References
MF8416
Download: ML16291A015 (2)


Text

1 NRR-PMDAPEm Resource From:

Sreenivas, V Sent:

Thursday, October 13, 2016 10:21 AM To:

steven.Capps@duke-energy.com Cc:

Robertson, Jeffrey N; Richards, Brian H; Vu, Phong T; Murphy, George M; Miller, Ed; Farnan, Michael

Subject:

McGuire Unit No. 2: ACCEPTANCE REVIEW-Relief Request Alternative Testing approval for Two PORV Block Valves (CAC Nos. MF8416)

By letter dated September 29, 2016, Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML16274A066, Duke Energy Carolinas, LLC (Duke Energy), the licensee, submitted alternative request to the Nuclear Regulatory Commission (NRC). The licensee requested an alternative test plan for two PORV Block Valves in lieu of certain inservice testing (IST) requirements of the 2004 Edition through 2006 Addenda of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code) for the IST program at McGuire Nuclear Station (MNS) Unit 2 during the fourth 10-year IST program interval.

Specifically, pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, section 50.55a(z)(2), the licensee requested to use proposed alternatives since complying with the current ASME OM Code requirements would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. The purpose of this e-mail is to provide the results of the NRC staffs acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed the submittal and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please do not hesitate to contact me.

V. Sreenivas, Ph.D., CPM.,

Project Manager NRR/DORL/LPL2-1 301-415-2597

Hearing Identifier:

NRR_PMDA Email Number:

3104 Mail Envelope Properties (V.Sreenivas@nrc.gov20161013102000)

Subject:

McGuire Unit No. 2: ACCEPTANCE REVIEW-Relief Request Alternative Testing approval for Two PORV Block Valves (CAC Nos. MF8416)

Sent Date:

10/13/2016 10:20:33 AM Received Date:

10/13/2016 10:20:00 AM From:

Sreenivas, V Created By:

V.Sreenivas@nrc.gov Recipients:

"Robertson, Jeffrey N" <Jeffrey.Robertson@duke-energy.com>

Tracking Status: None "Richards, Brian H" <Brian.Richards@duke-energy.com>

Tracking Status: None "Vu, Phong T" <Phong.Vu@duke-energy.com>

Tracking Status: None "Murphy, George M" <George.Murphy2@duke-energy.com>

Tracking Status: None "Miller, Ed" <Ed.Miller@nrc.gov>

Tracking Status: None "Farnan, Michael" <Michael.Farnan@nrc.gov>

Tracking Status: None "steven.Capps@duke-energy.com" <steven.Capps@duke-energy.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2433 10/13/2016 10:20:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: