Confirms 850326 Enforcement Conference at Region II Ofc to Discuss Inoperability of Control Area Ventilation Sys Chiller at McGuire & Radioactive Shipment Event at Oconee, Per Vl Brownlee 850228 Telcon.Proposed Meeting Agenda Encl
ML16288A715
Person / Time
Site: Oconee, Mcguire, McGuire, 05000000
Issue date: 03/22/1985
From: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Tucker H
DUKE POWER CO.
References
NUDOCS 8504160402
Download: ML16288A715 (2)


Text

W g

MAR 22 1985 Duke Power Company ATTN: Mr. H. B. Tucker, Vice President Nuclear Production Department 422 South Church Street Charlotte, NC 28242 Gentlemen:

SUBJECT:

CONFIRMATION OF MEETING - MCGUIRE AND OCONEE -

DOCKET NOS. 50-369, 50-370, 50-269, 50-270, and 50-287 This confirms our telephone conversation between G. E. Vaughan of your staff and V. L. Brownlee of my staff on February 28, 1985, concerning an Enforcement Conference to be conducted at the Region II Office on March 26, 1985 at 10:00 a.m.

We requested this meeting to discuss the inoperability of the Control Area Ventilation System Chiller at McGuire and the radioactive shipment event at Oconee. A proposed meeting agenda is enclosed.

Should you have any questions regarding these arrangements, we will be pleased to discuss them.

Sincerely, J. Nelson Grace Regional Administrator

Enclosure:

Proposed Meeting Agenda cc: T. L. McConnell, Station Manager, McGuire M. S. Tuckman, Station Manager, Oconee bcc w/encl:

NRC Resident Inspectors - McGuire and Oconee Document Control Desk State of North Carolina State of South Carolina 6504160402 850322 PDR ADOCK 05000269 S

PDR RI RII RII RI II RII WB yr HCDance VLBrownlee JM c 4

ett

-PRBemis JAt nski 3/o/85 3/w/85 3/ cY85

/Y >/85 3/jo/85 3/2/,85

MAR 22 1985 ENCLOSURE PROPOSED MEETING AGENDA DUKE POWER COMPANY March 26, 1985, 10:00 a.m.

I.

Opening Remarks J. N. Grace/R. D. Walker II. Discussion of inoperability of Control G. E. Vaughn Area Ventilation System Chiller

a. Sequence of Events
b. Effect on Instrumentation
c. Determining Inoperability III.

Radioactive shipment event G. E. Vaughn IV. Discussion Attendees V. Closing Comments J. N. Grace/R. D. Walker