ML16245A687
| ML16245A687 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 06/04/1979 |
| From: | Lainas G Office of Nuclear Reactor Regulation |
| To: | Reid R Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16245A399 | List: |
| References | |
| NUDOCS 7907110114 | |
| Download: ML16245A687 (3) | |
Text
DISTRIBUTION; Central Files NRC PDR PSB Reading jUH 1979 MEMORANDUM FOR: R. Reid,.Chief, Operating Reactors Branch #4 DOR FROM:
G. Lainas, Chief, Plant Systems Branch, DOR
SUBJECT:
SAFETY EVALUATION OF SPENT FUEL STORAGE RACK Plant Name: Oconee Nuclear Station, Units 1 & 2' Docket Nos.:
50-269 and 50-270.
TAC Nos.:
11433 and 11434 Project Manager: M. Fairfile Status:
Complete Enclosed is the Plant Systems Branch input to the Safety Evaluation Report for the Duke Power-Company's (DPC) propo'sed modification to the spent fuel storage pools for the Oconee Nuclear Station, Units 1 and 2.
We have reviewed the issues of criticality, cooling, rack installation, and fuel handling as they are discussed in the licensee's submittal supporting its proposed amendments to the facility's operating licenses.
We find-DPC's application for the license amendments acceptable with respect to the above listed issues, provided that the uranium-235 loading fo fuel assemblies that are to be placed in the pool is limited to the amount established as acceptable in this report and provided.that the additional spent fuel pool cooling capacity, which is described in the proposal, is installed in the..first quarter of 1980.1 G. Lainas, Chief Plant Systems Branch Division of Operating Reactors
Enclosure:
As stated
Contact:
9071101N E. Lantz X-27110 oPc B:DO SL
- DOR B:DOR U
RNAME ELantz:dn EAdensam finas OAT~
~5?f7.
0/79 D
5/YS79 5M0/79
/79 O
NRCt PORM 318 (9-76)
.NRCM'0240 U.S. GOVERNMENT PRNTIrNG oFr se: 1o7e - 2es
- 7so
vootREG(U4
$ Ro 0
UNITED STATES
,S NUCLEAR REGULATORY COMMISSION Z
WASHINGTON, D. C. 20555 JUN 4 1979 MEMORANDUM FOR: R. Reid, Chief, Operating Reactors Branch #4, DOR FROM:
G. Lainas, Chief, Plant Systems Branch, DOR
SUBJECT:
SAFETY EVALUATION OF SPENT FUEL STORAGE RACK Plant Name:
Oconee Nuclear Station, Units 1 & 2 Docket Nos.:
50-269 and 50-270 TAC Nos.: 11433 and 11434
.Project Manaqer: M. Fairtile Status: Complete Enclosed is the Plant Systems Branch input to the Safety Evaluation.Report for the Duke Power Company's (DPC) proposed modification to the spent fuel storage pools for the Oconee Nuclear Station, Units 1 and 2.
We have reviewed the issues of criticality, cooling, rack installation, and fuel handling as they are discussed in the licensee's submittal supporting its proposed amendments to the facility's operating licenses.
We find DPC's application for the license amendments acceptable with respect to the above listed issues, provided that the uranium-235 loading in fuel assemblies.that are to be placed in the pool is limited to the amount established as acceptable in this report and provided that the additional spent fuel pool cooling capacity, which is described in the proposal, is installed in the first quarter of 1980.
G. Lainas, Chief Plant Systems Branch Division of Operating Reactors
Enclosure:
As stated
Contact:
E. Lantz X-27110
-2 cc w/enclosure:
V. Stello D. Eisenhut R. Vollmer B. Grimes G. Lainas MIPC T. Telford W. Russell G. Knighton E. Adensam M. Fairtile E. Lantz