ML16244A060
| ML16244A060 | |
| Person / Time | |
|---|---|
| Site: | McGuire |
| Issue date: | 08/18/2016 |
| From: | Duke Energy Carolinas |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 16-MN-003, MNS-16-070, N-786-2 | |
| Download: ML16244A060 (11) | |
Text
ATTACHMENT 1 RR 16-MN-003 CODE CASE N-786-2
CASE ASME BPVC.CC.NC.SZ-2015 N-786-2 Approval Date: August 3, 2015 Code Cases will remain available for use until annulled by the applicable Standards Committee.
Case N-786-2 Alternative Requirements for Sleeve Reinforcement of Class 2 and 3 Moderate-Energy Carbon Steel Piping Section XI, Division l Inquiry: As an alternative to replacement or weld repair in accordance with IWA-4400, what requirements may be app li ed for wa ll reinforcement of Class 2 and 3 moderate-energy carbon steel piping systems that have experienced wall thinning from localized erosion, corro-sion, and cavitation or pitting?
Reply: It is the opinion of the Committee that, in lieu of IWA-4400, 1 Class 2 and 3 moderate-energy [i.e., less than or equal to 200°F (93 °C) and less than or equal to 275 psig (1.9 MPa) maximum operating conditions] car-bon steel piping experiencing wall thinning from localized erosion, corrosion, and cavitation or pitting (collectively referred to herein as corrosion) may have the wall thick-ness reinforced by applying full-circumferential reinfor-cing sleeves to the outside surface of the piping in accordance with the following requirements. Excluded from these provisions are conditions involving any form of cracking.
1 GENERAL REQUIREMENTS (a) Installation of the reinforcing sleeve shall be in ac-cordance with a Repair /Replacement Plan satisfying the requirements of IWA-4150.
(b) The design, materials, and installation shall meet the requirements of the Construction Code and IWA-4000, except as stated in this Case.
(c) If the minimum required thickness of reinforcing sleeve necessary to satisfy the requirements of 3 is great-er than 1.4 times the nominal thickness for the size and schedule of the piping, this Case may not be used.
(d) Additional reinforcement or repair is not permitted on top of an existing reinforcing sleeve.
(e) This Case may be applied only to piping not re-quired to be ultrasonically examined for inservice inspection.
(f) This Case may not be applied to pumps, valves, ex-pansion joints, vessels, heat exchangers, tubing, flanges, flanged joints, socket welded or threaded joints, or branch connection welds.
2 INITIAL EVALUATION (a) The material beneath the surface to which the rein-forcing sleeve is to be applied shall be ultrasonically mea-sured to establish the existing wall thickness and the extent and configuration of degradation to be reinforced.
The adjacent area shall be examined to verify that the re-pair will encompass the entire unacceptable area, and that the adjacent base material, including at least 0.75 J Rtnom of base metal beyond the toe of the attach-ment welds, is of sufficient thickness to accommodate the attachment welds at the edges of the sleeve.
(b) The cause and rate of degradation shall be deter-mined. The extent and rate of degradation in the piping shall be evaluated to ensure that there will be no other unacceptable locations within the surrounding area that could affect the integrity of the reinforced areas for the life of the repair. Surrounding areas showing signs of de-gradation shall be identified and included in the Owner's plan for thickness-monitoring inspections of full-structural reinforcing sleeves [see 8(c)]. The dimensions of the surrounding area to be evaluated shall be deter-mined by the Owner, based on the type and rate of degra-dation present.
(c) The effects of the reinforcing sleeve and attachment welds on the piping and any remaining degradation shall be evaluated in accordance with IWA-4311.
3 DESIGN 3.1 Types of Reinforcing Sleeves.
(a) Type A reinforcing sleeves as shown in Figure 1 may be used for structural reinforcement of thinned areas which are not expected to penetrate the wall and cause leakage. The piping longitudinal stresses shall meet the 1 The references to Section XI in this Case refer to the 2015 Edition. For use of this Case with other Editions and Addenda, refer to the Guide-line for Cross-Referencing Section XI Cases, Table 1.
The Committee's function is to establish rules of safety, relating only to pressure integrity, governing the construction of boilers, pressure vessels, transport tanks and nuclear components, and inservice inspection for pressure integrity of nuclear components and transport tanks, and to interpret these rules when questions arise regarding their intent. This Code does not address other safety issues relating to the construction of boilers, pressure vessels, transport tanks and nuclear components, and the inservice inspection of nuclear components and transport tanks. The user of the Code should refer to other pertinent codes, standards, laws, regulations or other relevant documents.
Copyright ASME tntemationa1 (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS 1 (N-786-2) licensee::Us Nuclear Regulatory Commission/9979306001 Not for Resale, 08116/2016 08:15:14 MDT NC - SUPP. 2
CASE (continued)
N-786-2 ASME BPVC.CC.NC.52-2015 requirements of the Construction Code. Type A reinfor-cing sleeves shall have a maximum service life of the time until the end of the next refueling outage.2
{b) Type B reinforcing sleeves as shown in Figure 2 may be used for pressure plus full-or partial-structural reinforcement of thinned areas that penetrate, or are ex-pected to penetrate the wall and cause leakage.
{1) Full-structural reinforcement is designed to ac-commodate pressure plus axial and circumferential de-sign loadings at the location for the design life of the repair without taking credit for any portion of the de-graded segment. Full-structural reinforcement sleeves shall be removed and the piping repaired or replaced in accordance with lWA-4000 no later than the end of the design life of the repair.
(2) Partial-structural reinforcement is designed to accommodate design loadings at the segment being rein-forced, taking partial credit for the degraded segment after factoring in predicted degradation over the life of the repair. Partial credit is considered taken if the design relies on any portion of the segment of piping beneath the sleeve, other than the base metal beneath the attachment welds, to provide structural or pressure integrity. Partial-structural reinforcing sleeves shall have a maximum ser-vice life of the time until the end of the next refueling outage.
3.2 General Design Requirements -
Type A and B Sleeves.
(a) The design of reinforcing sleeves shall be in accor-dance with the requirements of NC-3100 and NC-3600 or ND-3100 and ND-3600, and Section Ill Appendices, Mandatory Appendix II.
{b) Material for reinforcing sleeves shall be ferritic, with welds of compatible weld filler metal.
(c) The minimum width of reinforcing sleeves shall be 4 in. (100 mm).
(d) The thickness of the reinforcing sleeve shall be suf-ficient to maintain required thickness for the predicted life of the repair.
(e) The following factors shall be considered, as applic-able, in the design and application of the sleeves:
{1) all loading the sleeve is expected to encounter (2) shrinkage effects, if any, on the piping (3) stress concentrations caused by installation of the reinforcing sleeve or resulting from existing and pre-dicted piping surface configuration (4) effects of welding on any interior coating (5) differential thermal expansion between reinfor-cing sleeve, the attachment welds, and the pipe (6) potential for loose debris in the system from con-
. tinued degradation of the reinforced area of the piping (f) Longitudinal seam welds shall be full penetration.
- Backing may be applied to prevent burn-through of the pipe. If full contact between sleeve and pipe is required, any backing shall be recessed into the underside of the sleeve, or hardenable fill shall be used to fill the void, as indicated in Figure 3.
(g) Longitudinal seam joint efficiency of 0.8 shall be used, except that 100% joint efficiency is permitted if the longitudinal seam is volumetrically examined.
{h) Fatigue evaluation shall be performed if required for the original pipe, or if thermal gradients exceed 100°F (56°C), or if lesser thermal gradients will occur during more than 200 heatup and cool-down cycles over the life of the repair.
(i) If flexibility analysis was required by the original Construction Code, the effect of the reinforcement shall be reconciled with the original analysis.
(jJ Final configuration of the attachment welds shall permit the examinations and evaluations required herein, including any required preservice or inservice examina-tions of attachment or adjacent welds.
(k) The predicted maximum degradation of the carrier base metal and reinforcing sleeve over the design life of the reinforcement shall be based on in-situ inspection and established data for similar base metals.
The initial degradation rate selected for design of the sleeve shall be at least 2 times the maximum rate ob-served at that location; or if unknown, 4 times the esti-mated maximum degradation rate for that system or a similar system at the same plant site for the same degra-dation mechanism. If the degradation rate for that loca-tion and the cause of the degradation are not conclusively determined, 4 times the maximum degrada-tion rate observed for all degradation mechanisms for that system or a similar system at the same plant site shall be applied.
(/) Weld seams encompassed by the sleeve shall be ground flush. Alternatively, bulges may be rolled or formed in the sleeves to accommodate such obstructions.
Refer to Figure 4.
(m) Sleeves shall closely match the outside surface of the carrier piping. If required by design, gaps shall be filled with hardenable fill.
(n) Where sleeves are applied on the outside of piping to mitigate externally corroded areas with potential for bulging, the corrosion cavity shall be restored to the ori-ginal contour of the pipe with hard enable fill to minimize the gap beneath the sleeve.
(o) Hardenable fill shall be suitable for the system oper-ating conditions, and shall be compatible with the sleeve, weld metal, piping, and any exterior coating that is not re-moved from the piping.
(p) Branch connections may be installed on reinforcing sleeves only for the purpose of filling or venting during in-stallation, or for leak testing of the sleeve, and shall be limited to NPS 1 (DN 25) or smaller.
2 If a Type A or partial-structural Type B reinforcing sleeve is installed during a refueling outage, the maximum permitted service life is one fuel cycle, until the end of the next refueling outage.
NC - SUPP. 2 Copyright ASME International (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without license from 1HS 2 (N-786-2)
Ucensee=Us Nuclear Regulatory Commission/QQ7Q306001 Not for Resale, 08/ 1612016 08*15:14 MDT
CASE (continued)
ASME BPVC.CC.NC.52-2015 N-786-2 Figure l Type A Reinforcing Sleeve Type A Sleeve ~
Piping 3.3 Specific Requirements -
Type A Sleeves. Type A sleeves in moist environments shall have edges sealed, but not seal welded, to prevent moisture intrusion and corrosion.
3.4 Specific Requirements -
Type B Sleeves.
(a] If permitted by the design, suitable gasket material may be applied inside the sleeve to prevent moisture dur-ing welding (see Figure 2).
(b] Hardenable fill and gasket material shall be compa-tible with the system fluid.
(c] Partial-structural sleeves shall be designed to with-stand the design pressure.
(d) Partial-structural sleeves may be attached by fillet welds in accordance with the requirements of 3.2(a).
(e) Full-structural sleeves shall be attached by partial-penetration welds (see Figure 5) that, unless otherwise established by analysis in accordance with the require-ments of 3.2(a), extend for a distance of at leasts in each axial direction beyond the area predicted, over the design life of the repair, to infringe upon the required thickness,3 where s ~ 0.75 J Rtnom ands ~ I in. (25 mm) where R
D /2 = outer radius of the piping tn o m nominal wall thickness of the piping 3 Design thickness as prescribed by the Construction Code.
Full-penetration longitudinal seam The thickness of the partial-penetration attachment welds shall equal the thickness of the sleeve, and the out-er edges of the welds shall be tapered to the piping sur-face at a maximum angle ("a" in Figure 5) of 45 deg.
(fJ If flexibility analysis was required by the original Construction Code, and unless a lower stress intensifica-tion factor (SlF or i) is established, an SlF (i) of 2.1 shall be applied for attachment fillet welds and tapered edges of partial-penetration attachment welds on straight pipe and at adjacent welds. Also, a stress multiplier of 1.7 shall be applied to the SIF (i) for sleeves enclosing standard el-bows, and an SIF (i) of 2.1 shall be applied for sleeve at-tachments on tees and branch connections provided the toe of the fillet or tapered edge is not less than 2.5 ~ Rtnom from any branch reinforcement. (See Figure 5.)
4 WATER-BACKED APPLICATIONS (a) Manual welding of reinforcing sleeves on water-backed piping shall use the SMAW process and low-hydrogen electrodes.4 (b] When welding a reinforcing sleeve to a leaking area, precautions, such as installation of a gasket or sealant be-neath the sleeve, shall be taken to prevent welding on wet surfaces. Any residual moisture shall then be removed by heating prior to welding.
4 Testing has shown that piping with areas of wall thickness less than the diameter of the electrode may burn through during welding on water-backed piping.
Copyright ASME International (BPVC)
Provided by lHS under license with ASME No reproduction or networking permitted without license from IHS 3 (N-786-2) licenseezUs Nuclear Regulatory Commission/QQ79306001 Not for Resale, 08/16/2016 08:15:14 MDT NC - SUPP. 2
CASE (continued)
N-786-2 ASME BPVC.CC.NC.52-2015 Figure 2 Type B Reinforcing Sleeves 5-partial penetrat ion ~
attachment weld. See 3.4 (e) ~
Full penetration longitudinal seam Full penetration longitudinal seam Tapered edge
,,..---=;F"""=-=~-=-==-=-=i....----.
.,.._-4::i=-=-=~~s:::=--=r~--.
- ...... ---/.. :
I ~-- *t','
I I
/
I
~ _...:.. :..:.... __ J Partial-structural (c) For piping materials other than P-No. 1 Group 1, the surface examination of welds required in 6 shall be per-formed no sooner than 48 hr after completion of welding.
5 INSTALLATION (a) The circumference of the base material in the area to be welded or to provide backing for welding shall be cleaned to bare metal. The entire area shall be cleaned, if required for application of hardenable fill.
(b) The sleeve shall be fitted tightly around the pipe.
Preheating the sleeve to achieve a shrink fit, or use of me-chanical or hydraulic clamping, draw bolts, or other de-vices may be used to ensure fit.
(c) If hardenable fill is used, it may be applied prior to sleeve installation or pumped into the annulus between the sleeve and base metal after the sleeve is in place. If pumped into the annulus, provisions shall be made to pre-vent over-pressurization and intrusion of the hardenable fill into the system.
{d) Means shall be provided to isolate or divert leakage to eliminate moisture during welding. If welding is per-formed on a wet surface, the maximum permitted life of the reinforcing sleeve shall be the time until the next re-fueling outage.
(e) Weld metal shall be deposited using a groove-welding procedure qualified in accordance with Section IX and the Construction Code.
(f) Fillet weld leg le ngth shall be increased by the amount of fit-up gap. Care shall be exercised to avoid sharp discontinuities that could cause stress risers at the toes of fillet welds or tapered edges of partial-penetration attachment welds.
(g) Provision for venting during the final closure weld or pressure testing shall be made if necessary.
I
~...... /
I I
I
~-=....:..:..' __ )
Full-structural
{h) The surfaces of all welds shall be prepared, if neces-sary, by machining or grinding, to permit performance of surface and volumetric examinations required by 6. For ultrasonic examination, a surface finish of 250 RMS or better is required.
6 EXAMINATION (a) All welds shall be examined using the liquid pene-trant or magnetic particle method and shall satisfy the surface examination acceptance criteria for welds of the Construction Code or Section Ill (NC-5300 or ND-5300).
(b) Except for the tapered edges, partial-penetration at-tachment welds, including the piping base metal upon which they are applied, shall be measured ultrasonically to verify and record baseline wall thickness.
(c) Longitudinal seam welds in the sleeve shall be ultra-sonically or radiographically examined in accordance with the Construction Code or Section Ill if longitudinal seam welds in the piping require volumetric examination.
If the design does not permit a joint efficiency of 0.8, Class 3 longitudinal seam welds may be examined in accor-dance with ( d), in lieu of volumetric examination.
(d) Partial-penetration attachment welds (Figure 2) shall be volumetrically examined when full-penetration girth welds in the carrier piping are required by the Con-struction Code to be volumetrically examined. Where con-figu ration does not permit meaningful volumetric examination, and for Class 3 longitudinal seam welds re-quiring volumetric examination (see (c)], the first layer, each 1/i in. thickness of weld deposit, and final surface shall be examined in accordance with (a), in lieu of volu-metric examination.
(e) When volumetric examination is required, the full volume of the attachment weld, excluding the tapered edges but including the volume of base metal required for the service life of the reinforcing sleeve, shall be NC-SUPP. 2 4 (N-786-2)
Copyright ASME 1ntamational (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Ucensee* Us Nuclear Regulatory Commission/0071;1306001 Not for Resale, 0811612016 08*15:14 MDT
CASE (continued)
ASME BPVC.CC.NC.SZ-2015 N-786-2 Figure 3 Type A and Type B Sleeve Longitudinal Seams No Backing Strip Hardenable fi ll Backing Strip Backing Strip With Recess Without Recess examined in accordance with the Construction Code or Section Ill using either the ultrasonic or radiographic method, and shall, to the depth at the surface of the pip-ing, satisfy the acceptance criteria for weldments of the Construction Code or Section Jll (NC-5300 or ND-5300).
Any volume of the piping beneath the reinforcing sleeve that is credited in the design shall satisfy the volumetric acceptance criteria of NC-5320 and ND-5330, or NC-5320 and ND-5330, as applicable.
7 PRESSURE TESTING In lieu of IWA-4540, a system leakage test of the repair/
replacement activity shall be performed in accordance with IWA-5000 prior to, or as part of, returning to service.
Type B reinforcing sleeves attached to piping that has not been breached shall be equipped with pressure taps for performance of pressure testing.
8 INSERVICE EXAMINATION (a) Preservice and inservice examination of Type B full-structural reinforcing sleeve welds shall be performed in accordance with IWC-2000 or IWD-2000, if required. [See 1( e ).)
(b) The Owner shall perform a base-line inspection of full-structural reinforcing sleeves, their attachment welds, adjacent base metal for a length of at least 0.75 J Rtnom* and the surrounding areas showing signs of degradation [see 2(b)), using ultrasonic or direct thick-ness measurement.
(c) The Owner shall prepare a plan to repeat the thick-ness monitoring inspections at least every refueling out-age, to verify that minimum design thicknesses as required by the Construction Code or Section Ill are not violated in the sleeve or at the attachment welds, includ-ing the underlying base metal.
(1) More frequent thickness monitoring inspections shall be scheduled when warranted by the degradation rates calculated using reductions in thicknesses observed during these inspections, such that the required design thicknesses will be maintained at least until the subse-quently scheduled thickness monitoring inspection.
(2) Provisions shall be made for access to full-structural reinforcing sleeves on buried piping in order to accomplish these inspections.
(d) Type A and partial-structural Type B reinforcing sleeves shall be visually monitored for evidence of leak-age at least monthly. If the areas containing these sleeves are not accessible for direct observation, monitoring shall be accomplished by visual assessment of surrounding areas or ground surface areas above reinforcing sleeves on buried piping, or by monitoring of leakage collection systems, if available.
(e) For Type A and partial-structural Type B reinfor-cing sleeves, regardless of when during a cycle or inspec-tion interval they are installed, the repair shall be considered to have a maximum service life of the time un-til the end of the next refueling outage.
(f) If the cause of the degradation is not determined, the maximum permitted service life of any reinforcing sleeve shall be the time until the end of the next refueling outage.
5 (N-786-2)
NC-SUPP. 2 Copyright ASME International (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Licensee=Us Nuclear Regulatory Commission/0079306001 Not for Resale, 08116/2016 08:15:14 MDT
CASE (continued)
N-786-2 NC - SUPP. 2 Copyright ASME International (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Constant root gap ASME BPVC.CC.NC.52-2015 Figure 4 Bulge to Accommodate Girth Weld 6 (N-786-2)
Ucensee=Us Nuclear Regulatory Commission/QQ7g300001 Not for Resale, 08/1612016 08:15:14 MDT
CASE (continued)
ASME BPVC.CC.NC.52-2015 N-786-2 Figure 5 Design Details -
Type B Full-Structural Sleeves I
J I
D l
LJ Minimum plate length =
predicted maximum degradation Copyright ASME International (BPVC)
Provided by IHS under license with ASME t
No reproduction or networking permitted without license from IHS r - -
I I
Required t thickness req
- ---x---- 1 Limit of branch reinforcement X 2: 2.5~ Rtnom
- 7 (N-786-2)
Ucensee* Us Nuclear Regulatory Commission1gg7g300001 Not for Resale, 08/1'512016 08:15'.14 MDT NC - SUPP. 2
Copyright ASME International (BPVC)
Provided by IHS under license with ASME No reproduction or networking permitted without ~cense from IHS INTENTIONALLY LEFT BLANK licensee=Us Nuclear Regulatory Commlssionfgg7g3osoo1 Not for Resale, 08/1612016 08:15:14 MOT
ATTACHMENT 2 RR 16-MN-003 SLEEVE DESIGN Temporary Sleeve Repair at lRN-883 and lRN-884 Existing 8" RN (service w ater) header SA-106 Gra de B Carbon steel schedule 40 Design pressure - 135 psig 1/ 4 Typ Note 1 Desig n temperature - 150 F( l RN-884) 102 F (l RN-883)
Existing 3" pipe stub SA-106 Grade B Carbon steel schedule 40 3.5" 0D 3-1 / 2" NPS sleeve SA-106 grade B carbon steel Schedule 40x 2.5" long
(-3.5" ID after machining).
Split a long axis Field to locate for w elding.
Note 2,3.4 Existing 1 RN-883/ l RN-884 Ball Drain Valves, 300# Class Existing 150# flanges to remain.
Omitted for clarity.
Typ Note l 1/8 3000# l /4" threaded carbon steel half coupling Typ. 2 places (Note 4)
Field to locate 0
Typ Note 1 1/4 Notes:
DETAIL A SCALE l: l Typ Far Side Note l. 5
- 2) Minor d imensional changes for sleeve are acceptable to a llow proper fitup and welding with Engineering approval.
- 3) Appropriate gasket materia l or sealant may be used between sleeve and base piping to eliminate w eld ing/water interface concerns if necessary.
- 4) Install l / 4" threaded carbon steel 3000#
half coup ling on both halves of sleeve for testing and venting. Field to locate. Install threaded carbon steel plug and seal w eld after testing.
SECTION B-B
- 5) Backing strips may be utilized for longitudinal w elds If field conditions require.
Sleeve may be machined as required for fitment of backing strips with Engineering approva l.
Pagel of 1