ML16228A041

From kanterella
Jump to navigation Jump to search
Summary Technical Reports for Reactor Vessel Specimen Capsule Tests for Byron Station, Units 1 and 2, Pursuant to 10 CFR 50,Appendix H and Related to License Renewal Commitment 19
ML16228A041
Person / Time
Site: Byron  
(NPF-037, NPF-066)
Issue date: 08/11/2016
From: Kanavos M
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML16228A044 List:
References
BYRON 2016-0078
Download: ML16228A041 (3)


Text

...

Exelon Generation August 11, 2016 L TR:

BYRON 2016-0078 File:

1.10.0101 (1D.101, 5D.105)

United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Byron Station, Units 1 and 2 Byron Generating Station 4450 North German Church Rd Byron. IL 61010-*9794 www.exeloncorp.com 10 CFR Part 50, Appendix H 10 CRF Part 54 Renewed Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and STN 50-455

Subject:

Transmittal of Summary Technical Reports for Reactor Vessel Specimen Capsule Tests for Byron Station, Units 1 and 2, pursuant to 10 CFR 50, Appendix H and related to Byron Station, Units 1 and 2, License Renewal Commitment 19

References:

1) Letter from M.P. Gallagher, Exelon Generation Company, LLC (Exelon) to US NRC, "Response to NRC Request for Additional Information, Set 37, dated July 7, 2014, related to the Byron Station, Units 1 and 2, and Braidwood Station, Units 1 and 2, License Renewal Application," dated July 28, 2014
2) Letter from Christopher G. Miller, US NRC, to M.P. Gallagher, Exelon Generation Company, LLC, "Safety Evaluation Report Related To The License Renewal of Byron Nuclear Station, Units 1 and 2, and Braidwood Nuclear Station, Units 1and2, (TAC NOS. MF1879, MF1880, MF1881, MF1882)," dated July 6, 2015 In Reference 2 (enclosure section 3.0.3.2.14), the NRC noted that Appendix H to 1 O CFR Part 50 states, "Each capsule withdrawal and the test results must be the subject of a summary technical report to be submitted within 1 year of the date of capsule withdrawal, unless an extension is granted by the Director, Office of Nuclear Reactor Regulation." The NRC further stated that upon receiving a renewed operating license, the surveillance capsules identified by Exelon as standby capsules would no longer be considered standby capsules; instead, they would be considered part of the program to meet the recommendations of the GALL Report and the requirements of 1 O CFR Part 50, Appendix H. The staff found that since the standby capsules had already been removed from the reactor vessels, they should be tested and summary reports should be submitted within 1 year of receiving the renewed license, unless the station submits a request for extension for approval by the Director, Office of Nuclear Reactor Regulation, within this period. Since Byron Station, Units 1 and 2 renewed licenses were issued on November 19, 2015, Byron is to submit test results for the tested capsules by November 19, 2016.

r L TR: BYRON 2016-0078 August 11, 2016 ATTN: Document Control Desk Page2 In Reference 1, Exelon Generating Company updated License Renewal Application Appendix A, Table A.5, "License Renewal Commitment list," adding Enhancement 2 to Commitment 19 in response to N RC Request for Additional Information (RAI) B.2.1.19-1 b. Enhancement 2 reads as follows, with Braidwood capsules not included for the purpose of this Byron letter:

"One (1) specimen capsule per reactor vessel, as designated below, irradiated to a neutron f/uence of one (1) to two (2) times the projected peak neutron fluence at the end of the period of extended operation will be withdrawn from the spent fuel pool, tested, and the summary technical report submitted to the NRG within one (1) year of receipt of the renewed license. Alternatively, if a request for extension of the testing' schedule is submitted in accordance with 1 O CFR Part 50, Appendix Hand granted by the Director, Office of Nuclear Reactor Regulation, specimen testing will be performed in accordance with that approved extension."

Reactor Vessel Capsule ID Capsule Fluence (Station, Unit)

(n/cm2)(E>1.0 MeVJ Byron, Unit 1 y

3.97E+19 Byron, Unit 2 y

4.19E+19 To satisfy 1 O CFR 50, Appendix H requirements, Attachments 1 and 2 to this letter provide the testing results for Byron Unit 1, Capsule Y and Byron Unit 2, Capsule Y identified in the table above. The attachment evaluations led to the following conclusions:

U1 Capsule Y received a fluence of 3.97x 1019 n/cm2 (E > 1.0 MeV) after irradiation to 18.81 EFPY, and the peak clad/base metal interface vessel fluence after 57 EFPY (end-of-license extension) of plant operation is projected to be 3.23 x 1019 n/cm2 (E > 1.0 MeV).

U2 Capsule Y received a fluence of 4.19 x 1019 n/cm2 (E > 1.0 MeV) after irradiation to 20.05 EFPY, and the peak clad/base metal interface vessel fluence after 57 EFPY (end-of-license extension) of plant operation is projected to be 3.04 x 1019 n/cm2 (E > 1.0 MeV).

For the U1 and U2 capsules, the measured percent decreases in upper-shelf energy for the surveillance forging and weld materials are less than the Regulatory Guide 1.99, Revision 2 predictions.

For the U1 and U2 capsules, with consideration of surveillance data, all beltline materials exhibit adequate upper-shelf energy levels for continued safe plant operation and are predicted to maintain an upper-shelf energy greater than 50 ft-lb through end-of-license extension (57 EFPY) as required by 10 CFR 50, Appendix G.

L TR: BYRON 2016-0078 August 11, 2016 ATTN: Document Control Desk Page 3 This submittal also satisfies the requirement in Enhancement 2 of license renewal Commitment 19 to submit a capsule test summary technical report within one year of receipt of the renewed licenses for Byron Station, Units 1 and 2.

There are no new regulatory commitments in this letter.

Should you have any questions concerning this submittal, please contact Mr. Douglas Spitzer, Regulatory Assurance Manager, at (815) 406-2800.

Respectfully, Mark E. Kanavos Site Vice President Byron Generating Station MEK/GC/sg Attachments: 1. WCAP-18054-NP, Revision 0, "Analysis of Capsule Y from the Exelon Generation Byron Unit 1 Reactor Vessel Radiation Surveillance Program,"

dated December 2015

2. WCAP-18056-NP, Revision 0, "Analysis of Capsule Y from the Exelon Generation Byron Unit 2 Reactor Vessel Radiation Surveillance Program,"

dated December 2015 cc:

Regional Administrator - NRC Region Ill NRC Senior Resident Inspector - Byron Generating Station