UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 August 2, 2016 NOTE TO:

FILE FROM:

Sherry Meador, Technical Secretary

/RA/

Advisory Committee on Reactor Safeguards The minutes of the subject meeting were certified on May 20, 2016 as the official record of the proceedings of that meeting.

UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 May 20, 2016 MEMORANDUM TO:

ACRS Members FROM:

Sherry Meador

/RA/

Technical Secretary, ACRS

SUBJECT:

CERTIFICATION OF THE MEETING MINUTES FROM THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS 634th FULL COMMITTEE MEETING HELD ON MAY 5-7, 2016, IN ROCKVILLE, MARYLAND The minutes of the subject meeting were certified on May 20, 2016 as the official record of the proceedings of that meeting. A copy of the certified minutes is attached.

Attachment:

As stated

UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 May 13, 2016 MEMORANDUM TO:

Sherry Meador, Technical Secretary Advisory Committee on Reactor Safeguards FROM:

J. Sam Armijo

/RA/

ACRS Chairman

SUBJECT:

MINUTES OF THE 634th MEETING OF THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS (ACRS),

MAY 5-7, 2016 I hereby certify, to the best of my knowledge and belief, that the minutes of the subject meeting are an accurate record of the proceedings for that meeting.

OFFICE ACRS ACRS/SUNSI Review NAME SMeador SMeador DATE 05/13/2016 05/13/2016 OFFICIAL RECORD COPY

MINUTES OF THE 634th MEETING OF THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS ROCKVILLE, MARYLAND The 634th meeting of the Advisory Committee on Reactor Safeguards (ACRS) was held in Conference Room T2B1, Two White Flint North Building, 11545 Rockville Pike, Rockville, Maryland, on May 5-7, 2016. A copy of the meeting agenda is attached.

The summary report [ML16155A117] from the ACRS Chairman to the NRC Chairman contains the following information for this meeting: (1) an accurate description of each matter discussed and (2) a list of all the documents issued or approved by the Committee. A copy of the summary report is attached. The documents received by the Committee are listed in the references of each committee letter associated with this meeting.

A transcript of selected portions of the meeting is available in the NRC's public document room (pdr.resource@nrc.gov or 1-800-397-4209), or from the Publicly Available Records System (PARS) component of NRCs document system (ADAMS), or at http://www.nrc.gov/reading-rm/doc-collections/acrs/agenda/. The presentation slides and handouts used during the meeting are attached to these transcripts.

ATTENDEES ACRS Members Dr. Dennis Bley (Chairman), Dr. Michael Corradini (Vice-Chairman), Dr. Pete Riccardella (Member-at-Large), Dr. Ronald Bellinger, Mr. Charles Brown, Dr. Dana A. Powers, Mr. Harold Ray, Dr. Joy Rempe, Mr. Gordon Skillman, and Mr. John Stetkar.

ACRS Staff A. Valentin M. Banks M. Snodderly K. Weaver A list of other attendees is attached.

UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555-0001 AGENDA 634th ACRS MEETING MAY 5-7, 2016 11545 ROCKVILLE PIKE, ROCKVILLE, MD THURSDAY, MAY 5, 2016, CONFERENCE ROOM T-2B1

1) 8:30 AM - 8:35 AM Opening Remarks by the ACRS Chairman (Open) (DCB/ADV) 1.1)

Opening Statement 1.2)

Items of Current Interest

2) 8:35 AM - 10:00 AM Additional Guidance to Support the Closure Plan for the Reevaluation of Flooding Hazards (Open) (JWS/MRS) 2.1)

Remarks by the Subcommittee Chairman 2.2)

Briefings by and discussions with representatives of the NRC staff regarding implementation of the mitigating strategies and flooding hazard reevaluation action plan 10:00 AM - 10:15 AM

      • BREAK ***
3) 10:15 AM - 11:45 AM Review of Fukushima Tier 2 Group 3 Recommendation Regarding Other Natural Hazards Screening Evaluations (Open) (JWS/KDW) 3.1)

Remarks by the Subcommittee Chairman 3.2)

Briefings by and discussions with representatives of the NRC staff regarding the reviews of other natural hazards screening evaluations 11:45 AM - 1:00 PM

      • LUNCH ***
4) 1:00 PM - 3:00 PM NuScale Topical Report TR-0515-13952, Risk Significance Determination - Use of RAW Importance Measure (Open/Closed)

(MLC/MB) 4.1)

Remarks by the Subcommittee Chairman 4.2)

Briefings by and discussions with representatives of the NRC staff regarding the safety evaluation associated with the subject NuScale topical report

[NOTE: A portion of this meeting may be closed in order to discuss and protect information designated as proprietary, pursuant to 5 U.S.C. 552b(c)(4).]

5) 3:00 PM - 6:00 PM Preparation of ACRS Reports (Open/Closed) 5.1)

Updated Guidance for Performing the Integrated Assessment for External Flooding (JWS/MRS) 5.2)

Review of Fukushima Tier 2 Group 3 Recommendation Regarding Other Natural Hazards Screening Evaluations (JWS/KDW) 5.3)

NuScale Topical Report TR-0515-13952, Risk Significance Determination - Use of RAW Importance Measure (MLC/MB)

[NOTE: A portion of this meeting may be closed in order to discuss and protect information designated as proprietary, pursuant to 5 U.S.C. 552b(c)(4).]

FRIDAY, MAY 6, 2016, CONFERENCE ROOM T-2B1

6) 8:30 AM - 10:00 AM Future ACRS Activities/Report of the Planning and Procedures Subcommittee (Open/Closed) (DCB/ADV) 6.1)

Discussion of the recommendations of the Planning and Procedures Subcommittee regarding items proposed for consideration by the Full Committee during future ACRS meetings 6.2)

Report of the Planning and Procedures Subcommittee on matters related to the conduct of ACRS business, including anticipated workload and member assignments

[NOTE: A portion of this meeting may be closed pursuant to 5 U.S.C. 552b (c) (2) and (6) to discuss organizational and personnel matters that relate solely to internal personnel rules and practices of the ACRS, and information the release of which would constitute a clearly unwarranted invasion of personal privacy.]

7) 10:00 AM - 10:15 AM Reconciliation of ACRS Comments and Recommendations (Open) (DCB/ADV/MLB) 7.1)

Discussion of the responses from the NRC Executive Director for Operations to comments and recommendations included in recent ACRS reports and letters 10:15 AM - 10:30 AM

      • BREAK ***
8) 10:30 AM - 6:00 PM Preparation of ACRS Reports (Open/Closed) 8.1)

Continue discussion of the proposed ACRS reports listed under Item 5

[NOTE: A portion of this meeting may be closed in order to discuss and protect information designated as proprietary, pursuant to 5 U.S.C. 552b(c)(4).]

SATURDAY, MAY 7, 2016, CONFERENCE ROOM T-2B1

9) 8:30 AM - 11:30 AM Preparation of ACRS Reports (Open/Closed) 9.1)

Continue discussion of the proposed ACRS reports listed under Item 5

[NOTE: A portion of this meeting may be closed in order to discuss and protect information designated as proprietary, pursuant to 5 U.S.C. 552b(c)(4).]

10) 11:30 AM - 12:00 PM Miscellaneous (Open) (DCB/ADV) 10.1) Discussion of matters related to the conduct of Committee activities and specific issues that were not completed during previous meetings, as time and availability of information permit NOTES:

When appropriate, members of the public and representatives of the nuclear industry may provide their views during the briefings.

During the meeting, 301-415-7360 should be used in order to contact anyone in the ACRS Office.

Presentation time should not exceed 50 percent of the total time allocated for a given item. The remaining 50 percent of the time is reserved for discussion.

Thirty five (35) hard copies and one (1) electronic copy of the presentation materials should be provided to the ACRS in advance of the briefing.

One (1) electronic copy of each presentation should be emailed to the Designated Federal Official 1 day before the meeting. If an electronic copy cannot be provided within this timeframe, presenters should provide the Designated Federal Official with a CD containing each presentation at least 30 minutes before the meeting.

UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 June 8, 2016 The Honorable Stephen G. Burns Chairman U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

SUMMARY

REPORT - 634th MEETING OF THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS, MAY 5-6, 2016

Dear Chairman Burns:

During its 634th meeting, May 5-6, 2016, the Advisory Committee on Reactor Safeguards (ACRS) discussed several matters and completed the following letters and memoranda:

LETTERS Letters to Victor M. McCree, Executive Director for Operations, NRC, from Dennis C. Bley, Chairman, ACRS:

NRC Staff Updated Assessment of Fukushima Tier 2 Recommendations Related to Evaluation of Natural Hazards other than Seismic and Flooding, dated May 17, 2016 Draft Interim Staff Guidance JLD-ISG-2016-01, Guidance for Activities related to Near-Term Task Force Recommendation 2.1, Flooding Hazard Reevaluation; Focused Evaluation and Integrated Assessment, dated May 18, 2016 NuScale Power, LLC Licensing Topical Report, Risk Significance Determination, dated May 18, 2016 MEMORANDA Memoranda to Victor M. McCree, Executive Director for Operations, NRC, from Andrea D.

Valentin, Executive Director, ACRS:

Documentation of Receipt of Applicable Official NRC Notices to The Advisory Committee on Reactor Safeguards for May 2016, dated May 16, 2016 Draft Regulatory Guide 1.117, Protection against Extreme Winds and Missiles for Nuclear Power Plants, Revision 2, dated May 16, 2016 HIGHLIGHTS OF KEY ISSUES 1.

Draft Interim Staff Guidance JLD-ISG-2016-01, Guidance for Activities related to Near-Term Task Force Recommendation 2.1, Flooding Hazard Reevaluation; Focused Evaluation and Integrated Assessment The Committee met with representatives of the NRC staff and the Nuclear Energy Institute (NEI) to discuss draft Interim Staff Guidance JLD-ISG-2016-01, Guidance for Activities Related to Near-Term Task Force Recommendation 2.1, Flooding Hazard Reevaluation; Focused Evaluation and Integrated Assessment. Interim Staff Guidance JLD-ISG-2016-01 endorses, with some clarifications, the graded evaluation process and guidance in NEI 16-05, External Flooding Integrated Assessment. The integrated assessments and focused evaluations of reevaluated flooding hazards described in NEI 16-05 may account for the FLEX mitigation strategies in the context of overall plant response, or they may confirm that flood protection strategies and installed plant equipment can effectively cope with the reevaluated flood, without benefit from the FLEX equipment.

Committee Action The Committee issued a letter to the NRC Executive Director for Operations on this matter, dated May 18, 2016, with the following conclusions and recommendations: 1) Except for the treatment of flooding from local intense precipitation, the graded approach that is endorsed in JLD-ISG-2016-01 provides an appropriate framework to evaluate the plant-specific effects from reevaluated flooding hazards, 2) If mitigation strategies are needed to maintain or restore key safety functions during a flood caused by local intense precipitation, the staff should review those evaluations in the same manner as the integrated assessments that are performed for other flooding mechanisms, 3) The staff should better specify expectations for assurance of reliable personnel performance in the integrated assessments that are performed according to the guidance for the higher frequency scenarios in Path 5 and all scenarios in Path 4, 4) The staff should develop guidance to ensure that the evaluations examine external flooding scenarios that result from seismic events which also cause damage at the plant site, and 5) It would be challenging to conduct comprehensive and timely peer review of these flooding assessments according to the guidance and expectations.

2.

NRC Staff Updated Assessment of Fukushima Tier 2 Recommendations Related to Evaluation of Natural Hazards other than Seismic and Flooding The Committee met with the NRC staff to discuss the staffs White Paper, NRC Staff Updated Assessment of Fukushima Tier 2 Recommendations related to Evaluation of Natural Hazards other than Seismic and Flooding. The staff discussed its assessments and conclusions, and their plans to complete these evaluations by the end of 2016.

Committee Action The Committee issued a letter to the NRC Executive Director for Operations on this matter, dated May 18, 2016, with the following conclusions and recommendations: 1) We agree with the staffs conclusion that further evaluation of the effects from high winds and snow loads is warranted, 2) We plan to review the analyses which support the staffs conclusions that no further effort is needed to examine the effects from downstream dam failures and intake water seiche conditions at selected sites, 3) The staff has provided adequate justification for excluding most other natural hazards from further evaluation. The following items merit additional attention: Hazards that may disable the ultimate heat sink as a source of water with adequate quality to support long-term heat removal. Hazards that may prevent reliable operation of plant equipment and alternative mitigation equipment which rely on adequate air quality for combustion or ventilation, and 4) The staff should remain involved in the multi-agency investigation of severe geomagnetic storms. They need to distill from this effort expeditiously those factors important for the regulatory process.

3.

NuScale Power, LLC Licensing Topical Report, Risk Significance Determination The Committee met with representatives of the NRC staff to discuss its review of the NuScale Topical Report, Risk Significance Determination. The topical report outlined the proposed methodology for defining the term significant to identify candidate risk significant structures, systems, and components (SSCs) for input to the NuScale Design Reliability Assurance Program. The topical report methodology involves the use of alternative metrics compared to Regulatory Guide 1.200, An Approach for Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-Informed Activities, for defining the term significant.

Committee Action The Committee issued a letter to the NRC Executive Director for Operations on this matter, dated May 18, 2016, with the following conclusion and recommendations: 1) The staff continues to deal with criteria for determining risk significance in a case-by-case manner and this can lead to inconsistencies in regulatory positions, 2) The staff should develop a consistent approach by adopting a continuous scale to determine quantitative risk significance criteria, with more margin allowed for plants with lower risk, 3) The proposed approach by NuScale is reasonable provided that the core damage frequency (CDF) or large release frequency (LRF) remains consistent with their current estimates in the licensing topical report, and 4) The staff will need to address the multi-module aspects of the NuScale design that could alter the CDF and LRF risk estimates and associated SSCs classification.

RECONCILIATION OF ACRS COMMENTS AND RECOMMENDATIONS The Committee considered the Executive Director for Operations response of April 7, 2016, to the March 15, 2016 ACRS letter, Non-power Production or Utilization Facilities Proposed License Renewal Rulemaking. The Committee was satisfied with the Executive Director for Operations response.

SCHEDULED TOPICS FOR THE JUNE 2016 ACRS MEETING The ACRS meeting scheduled to be held on June 8-10, 2016 was canceled.

Sincerely,

/RA/

Dennis C. Bley Chairman