STPEGS UFSAR Q&R 12.1-1 Revision 13 Question 331.6 With regard to the review of the design process, and changes made as a result, to assure that occupational radiation exposures are as lo w as is reasonably achievable (ALARA):

1. Identify by title the individuals who have been responsible for the radiation protection aspects of the design review, and describe their rela tionship to the individua l responsible for the overall plant design.
2. Provide a breakdown by title of radiation protection personnel who have b een participating in such reviews, tabulating the health physics education and experience required of each.
3. Describe formal arrangements and procedures fo r assuring that adequate radiation protection reviews are performed throughout the design and construction processes and that adequate records are kept to document the completion of each such review.
4. Describe specific examples of actual dose-reducing changes in design that have resulted from these radiation protection design reviews.

Response The response as applicable to the design and cons truction phase of the Sout h Texas Project is found in the Final Safety Analysis Report, Amendment 62. For information concerning the current program for reviewing designs for as low as is reasonably achievable considerations, see Chapter 12 of the U pdated Final Safety Analysis Report, Section 12.1.