Text
SHEET 1 FROM URANIUM IX TRAIN 5 TK-801 VFD PI 801 21 LI 801 LIT 801 LAL 801 LALL 801 LAH 801 XC 801 INJECTION SKID (BY OTHERS)
ZONE D1 YI 801 SC 801 21 KUR-ENVI01-001-DWG-P215 2
B DESIGN AUTHORITY S MOORE KURION ENGINEER R ORME KURION CHECKER L STAMPER KURION PROJECT MANAGER J LUEY KURION BURIAL AREA #1 PROCESS P&ID TANK 801 B
2 NONE A
8 B
C 7
6 DRAWING TRACEABILITY LIST DWG NO 5
TITLE D
E F
8 7
6 5
REVISIONS NEXT USED ON REF NUMBER REFERENCES 4
TITLE REV REL MFD DESCRIPTION 3
DATE BY REV ENGR COMPANY 2
SIZE SCALE F
EDT DWG NO REV 1
SHEET OF A
OF SH C
4 3
2 D
E 1
F DATE COMPANY NAME DRAWN BY KURION Isolating Waste from the Environment 1355 Columbia Park Trail Richland, WA 99352 P: (509) 737-1377 www.kurion.com CIMARRON PUMP AND TREAT SYSTEM PROJECT ISSUED FOR 60% DESIGN NOT APPROVED FOR CONSTRUCTION HIGH ALARM INCREASE SPEED OF P-801.
LOW ALARM REDUCE SPEED OF P-801.
GENERAL NOTES:
1 INTERLOCKS:
ON LOW LOW ALARM SHUT DOWN P-801.
21 2
2 1
AVANTech I
N C
O R
P O
R A
T E
D
FLOW RATE DESIGN (GPM)
WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING A
B C
D 1
2 3
4 5
6 E
F G
H 7
8 9
10 11 12 P - 001 A/B 20 15 104 AMBIENT 125 125 CARBON STEEL N/A 5
HORIZANTAL CENTRIFUGAL P - 005 A/B DUAL-MEDIA FILTERS BW PUMPS 20 15 104 AMBIENT 400 360 CARBON STEEL N/A 15 HORIZANTAL CENTRIFUGAL ITEM NUMBER SERVICE MATERIAL VOLUME (m³)
RATED POWER (HP)
DESCRIPTION/TYPE M
M PIT 0452 P - 001A BIOREACTOR FEED PUMPS V-0324 CV-0321 V-0323 CV-0322 VFD M
M V-0428 CV-0463 V-0429 V-0430 V-0427 CV-0462 VFD DUAL-MEDIA FILTERS BACKWASH PUMPS BIOREACTOR FEED PUMPS SKID VFD XV 0320 VFD XV 0431 PIT 0355 3" x 6" SUCTION PRESSURE DESIGN (PSIG) WORKING V-0326 V-0325 PIT 0354 DUAL MEDIA FILTERS BACKWASH TANK TK - 003 P - 001B P - 005B AVANTech I
N C
O R
P O
R A
T E
D WT.:
REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 1 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM A
FOR REVIEW 7/17/15 VG KUR-ENVI01-001-DWG-P921 TK - 003 DUAL-MEDIA FILTERS BW TANK ATM ATM 100 AMBIENT POLY-ETHYLENE 5000 N/A SHEET 6, ZONE D3 DUAL MEDIA FILTERS FROM P - 005A SHEET 6, ZONE C12 DUAL MEDIA FILTERS TO FROM URANIUM IX TRAINS 2,3 & TK-401 SHEET 2, ZONE D12 BIOREACTORS TO 3" CS 3" CS 2" CS 2" CS V-0431 V-0320 3" CS 3" CS 3" CS 3" CS 3" CS 1H200-1504-D 15-04 M
FIT 0350 FIC 0350 YI 001B SC 001B YI 001A SC 001A PI 0354 PI 0355 PI 0354 YI 005B SC 005B M
FIT 0350 FIC 0450 YI 005A SC 005A B
A B
C D
1 2
3 4
5 6
E F
G H
7 8
9 10 11 12 FLOW RATE DESIGN (CFM)
WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING 11-T 0654 A/B ATM ATM 104 AMBIENT 15 10.5 COATED CARBON STEEL 33000 N/A ICB BIOREACTORS B - 001A/C/D/E BLOWERS 6.5 5
104 AMBIENT 100 N/A 10 POSITIVE DISPLACEMENT ITEM NUMBER SERVICE MATERIAL VOLUME (GALLON)
RATED POWER (HP)
DESCRIPTION/TYPE BIOREACTOR TANKS MV-0601 LT 0653 HH 95%
LL 10%
CV-0675 V-0693 VENT WITH INSECT SCREEN V-0604 V-0606 V-0608 V-0610 V-0603 V-0605 V-0607 V-0609 MV-0602 LT 0654 HH 95%
LL 10%
VENT WITH INSECT SCREEN V-0612 V-0614 V-0616 V-0618 V-0611 V-0613 V-0615 V-0617 VFD M
M M
M CV-0652A CV-0652C CV-0652D CV-0652E BLOWER SKID 4" x 2" 4" x 2" 4" x 2" 4" x 2" FI 0653 6" x 4" FI 0654 PG 0654 TG 0654 B - 001A 6" CS 4" CS 4" CS 4" CS 3" CS 3" CS 4" x 3" 4" x 3" 4" x 3" 4" x 3" 4" x 3" 4" x 3" 4" x 3" 4" x 3" V-0654A V-0654C V-0654D V-0654E CV-0654A MV-0694A CV-0654BV-0694B BIOREACTOR TANK - 1 VFD VFD VFD 8"
8" 6" CS BIOREACTOR TANK - 2 1/2" SS 1/2" SS 1/2" SS 6"CS SC T6 SC T6 SC T6 SC T6 SC T6 SC T6 SC T6 SC T6 MV-0641 MV-0640 1/2" 6" CS AVANTech I
N C
O R
P O
R A
T E
D WT.:
REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 2 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
A FOR REVIEW 7/17/15 VG B - 001B B - 001C B - 001D SHEET 4, ZONE F8 PHOSPHORIC ACID INJECTION PUMPS FROM SHEET 4, ZONE D8 NUTRIENT INJECTION PUMPS FROM SHEET 1, ZONE C7 BIOREACTORS FROM SHEET 3, ZONE G12 BIOREACTOR SLUDGE PUMPS TO SHEET 3, ZONE D7 BIOREACTOR SYSTEM TRANSFER PUMPS TO KUR-ENVI01-001-DWG-P921 1H200-1504-D 15-04 NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM 6"CS AE 0653 PRV-0651A PRV-0651B 2" CS PRV-0651C PRV-0651D 2" CS 2" CS 2" CS SHEET 5, ZONE C3 CENTRATE PUMP FROM CV-0676 V-0694 CV-0677 V-0695 1"CS SHEET 4, ZONE D3 HCL ACID INJECTION PUMPS FROM CV-0678 V-0696 1/2" SS AE 0651 AI 0651 NITRATE pH AI 0653 LI 0654 YI 001D SC 001D YI 001C SC 001C YI 001B SC 001B YI 001A SC 001A AE 0654 ORP AI 0654 AE 0655 pH AI 0655 AE 0656 ORP AI 0656 AE 0657 AI 0657 DO AE 0658 AI 0658 DO LI 0653 B
FLOW RATE DESIGN (GPM)
WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING A
B C
D 1
2 3
4 5
6 E
F G
H 7
8 9
10 11 12 P - 002 A/B 40 30 104 AMBIENT 125 125 CARBON STEEL N/A 7 1/2 HORIZONTAL CENTRIFUGAL P - 003 A/B BIOREACTOR SLUDGE PUMPS 20 20 104 AMBIENT 30 30 CARBON STEEL N/A 5
HORIZONTAL CENTRIFUGAL ITEM NUMBER SERVICE MATERIAL VOLUME (GALLON)
RATED POWER (HP)
DESCRIPTION/TYPE M
M PIT 0152 SYSTEM TRANSFER PUMPS V-0224 CV-0221 MV-0622 V-0223 CV-0222 I
M M
V-0127 CV-0662 V-0126 V-0125 V-0128 CV-0663 CE 0255 AE 0254 BIOREACTOR SLUDGE PUMPS SKID SYSTEM TRANSFER PUMP SKID V-0230 3" x 1" 6" x 3" 6" x 3" 3" CS 3" CS 3" CS 1" CS VFD XV 0224 TDS 0-5000 ppm TURBIDITY 0-1000 NTU I
XV 0627 PIT 0255 3" WP B03 1106500 2" x 3" SUCTION PRESSURE DESIGN (PSIG) WORKING MV-0226 2V-0226 PIT 0254 AVANTech I
N C
O R
P O
R A
T E
D REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 3 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
A FOR REVIEW 7/17/15 VG P - 003B P - 003A P - 002A P - 002B SHEET 2, ZONE C6 BIOREACTOR TANKS FROM SHEET 5, ZONE G12 CENTRIFUGE SYSTEM SLUDGE HOLDING TANK TO SHEET 2, ZONE C5 BIOREACTOR TANKS FROM SHEET 5, ZONE D12 POLYMER ACTIVATION MIXER TO SHEET 6, ZONE H12 DUAL MEDIA FILTERS TO KUR-ENVI01-001-DWG-P921 1H200-1504-D 15-04 NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM VFD VFD VFD 3" CS 3" CS 3" CS 3" CS YI 003B SC 003B YI 003A SC 003A PI 0152 PI 0254 PI 0255 CI 0255 AI 0254 YI 002A SC 002A YI 002B SC 002B AE 0252 AI 0252 NITRATE M
FIT 0350 FIC 0350 B
V-0701 LT 0756 FLOW RATE DESIGN (gal/hr)
WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING P - 010 A/B 145 40 104 AMB 20 10 PVC/EPDM N/A 0.067 GRUNDFOS DDC SERIES SMART DIGITAL DOSING PUMP ITEM NUMBER SERVICE MATERIAL VOLUME (Gallon)
RATED POWER (kW)
DESCRIPTION/TYPE PHOSPHORIC ACID INJECTION PUMP A
B C
D 1
2 3
4 5
6 E
F G
H 7
8 9
10 11 12 M
M V-0702 YS-0702 V-0705 YS-0705 V-0703 V-0707 V-0708 PG 0709 PD-0709 0 - 100 PSIG P - 011 A/B 145 40 104 AMB 2
PVC/EPDM N/A 0.067 GRUNDFOS DDC SERIES SMART DIGITAL DOSING PUMP NUTRIENT INJECTION PUMP P - 012 A/B 145 40 104 AMB 2
PVC/EPDM N/A 0.067 GRUNDFOS DDC SERIES SMART DIGITAL DOSING PUMP POLYMER INJECTION PUMP CHEMICAL ADDITION SKID V-0706 M
M PG 0819 0 - 100 PSIG V-0811 V-0812 YS-0812 V-0815 YS-0815 MV-0813 MV-0817 MV-0818 PD-0819 V-0816 DRAIN DRAIN 1/2" SS 1/2" SS 1/2" SS 1/2" SS 1/2" SS 1/2" SS AVANTech I
N C
O R
P O
R A
T E
D WT.:
REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 4 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
A FOR REVIEW 7/17/15 VG LS 0657 M
M PG 0919 0 - 100 PSIG V-0911 V-0912 YS-0912 V-0915 YS-0915 V-0913 V-0917 V-0918 PD-0919 V-0916 DRAIN 1/2" SS 1/2" SS 1/2" SS 1/2" SS LS 0857 NUTRIENT TANK METHANOL PHOSPHORIC ACID POLYMER INJECTION KUR-ENVI01-001-DWG-P921 1H200-1504-D 15-04 NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM LS 0657 M
M PG 0619 0 -100 PSIG V-0611 V-0612 YS-0612 V-0615 YS-0615 V-0613 V-0617 V-0618 PD-0619 V-0616 DRAIN 1/2" SS 1/2" SS 1/2" SS 1/2" SS HCL ACID P - 013 A/B 145 40 104 AMB 2
PVC/EPDM N/A 0.067 GRUNDFOS DDC SERIES SMART DIGITAL DOSING PUMP ACID INJECTION PUMP P - 012A P - 012B P - 011A P - 011B P - 010A P - 010B P - 013A P - 013B SHEET 5, ZONE C12 DEWATERING SYSTEM TO SHEET 2, ZONE G12 BIOREACTOR TANKS FEED TO SHEET 2, ZONE F12 BIOREACTOR TANKS FEED TO SHEET 2, ZONE G12 BIOREACTOR SLUDGE PUMPS TO CHEMICAL ADDITION SKID PLC DI PLC DI PLC DI PLC DI SC 0012A SC 0012B SC 0011A SC 0011B SC 0010A SC 0010B SC 0013A SC 0013B B
FLOW RATE DESIGN (GPM / CFM)
WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING A
B C
D 1
2 3
4 5
6 E
F G
H 7
8 9
10 11 12 TK - 001 ATM ATM 104 AMBIENT COATED CARBON STEEL 2500 N/A SLUDGE HOLDING TANK P - 004 CENTRIFUGE FEED PUMP 45 30 104 AMBIENT 5
3 COATED CARBON STEEL N/A 3
PROGRESSIVE CAVITY ITEM NUMBER SERVICE MATERIAL VOLUME (GALLON)
RATED POWER (HP)
DESCRIPTION/TYPE LT 0663 HH 90%
LL 10%
MV-6591 PCV 0691 M
MCC TK - 001 SLUDGE HOLDING TANK 2" x 1/2" 2" CS MV-06208 CV-06208 FI 0655 M
MV-06231 CV-06230 1 1/2" x 1" PG 0626 TG 0626 VENT WITH INSECT SCREEN MV-06207 CV-06207 M
M MV-06211 CV-06211 MV-06210 YS-06210 MV-06201 MV-06202 MV-06203 MV-06205 MV-06204 MV-06206 MV-06209 LT 0665 HH 10%
LL 10%
MV-06220 MV-06221 MV-06222 CENTRATE TANK AND CENTRATE PUMP TK-002 PG 0621 1" CS 2" CS PG 0625 PG 0624 BS-0625 BS-0626 1/2" AI B10 1106273 MV-06230 X-0628 X-0627 PVSV 0630 1"
1 BAR 24" MANWAY 3" CS 1/2" SS 3" CS 4" CS 4" CS 1" CS 1" x 1/2" 1/2 x 1/4" 1/2 x 1/4" 1/2 1 1/2" FB 1 1/2" FB 1 1/2" FB TSHH 0624 1"
1/2 x 1 1/2" 3" x 1/2" MV-06219 PRESSURE DESIGN (PSIG ) WORKING N/A N/A 2-1/2 1-1/2 CS AVANTech I
N C
O R
P O
R A
T E
D WT.:
REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 5 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
A FOR REVIEW 7/17/15 VG B - 002 N/A X - 001 CENTRIFUGE ATM ATM 104 AMBIENT 1.0 0.07 CARBON STEEL/ALUMINIUM
.06 15 VERTICAL CENTRIFUGE TK-002 CENTRATE AND DECANT TANK ATM ATM 104 AMBIENT STAINLESS STEEL 55 CENTRATE AND DECANT TANK P - 006 CENTRATE RECYCLE PUMP 30 5
104 AMBIENT 10 7
COATED CARBON STEEL N/A 3
HORIZONTAL CENTRIFUGAL B-002 SLUDGE AREATION BLOWER 8
6 104 AMBIENT 42 100 COATED CARBON STEEL N/A 10 ROTARY VANE BLOWER P - 004 P - 006 KUR-ENVI01-001-DWG-P921 1H200-1504-D 15-04 NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM SHEET 2, ZONE H12 BIOREACTORS FEED TO SHEET 4, ZONE H8 POLYMER INJECTION PUMPS FROM SHEET 3, ZONE F8 BIOREACTOR SLUDGE PUMPS FROM SHEET 3, ZONE D2 BIOREACTORS TRASNFER PUMPS FROM M
CMP - 001 VFD YI 002A SC 002A LI 0655 VFD YI 006 SC 006 VFD YI 002 SC 002 LI 0655 B
X - 001 SLUDGE CART C
FLOW RATE DESIGN GPM WORKING TEMPERATURE DESIGN
(ºF)
WORKING PRESSURE DESIGN (PSIG) WORKING A
B C
D 1
2 3
4 5
6 E
F G
H 7
8 9
10 11 12 PV - 1100 A/B DULA MEDIA VESSELS 100 40 100 AMBIENT 125 125 CARBON STEEL 7
N/A PRESSURE VESSEL ITEM NUMBER SERVICE MATERIAL DIAMTER (FT)
RATED POWER (HP)
DESCRIPTION/TYPE DULA MEDIA FILTERATION SKID SUCTION PRESSURE DESIGN (PSIG) WORKING N/A N/A 3" CS 4" CS V-1100A SERVICE INLET V-1101A V-1104A BACKWASH OUTLET V-1107A BACKWASH INLET 3" CS RINSE OUTLET SERVICE OUTLET V-1102A V-1107A MV-1106A 3" CS V-1104A VV-1100A 18" x 24" MANWAY 3" MEDIA REMOVAL PAD FLANGE 3" CS 4" CS MV-1100B SERVICE INLET V-1101B V-1104B BACKWASH OUTLET 4" CS BACKWASH INLET 3" CS SERVICE OUTLET MV-1107B MV-1106B 4" CS V-1104B VV-1100B 18" x 24" MANWAY 3" MEDIA REMOVAL PAD FLANGE V-1105B V-1105A PV-1100A PV-1100B 4" CS 4" CS MEDIA MONITORING NOZZLE MEDIA MONITORING NOZZLE 3" CS 3" CS 569 GPM 3" CS 1" CS 4" CS 4" CS 3" CS 1" CS V-1103A V-1103B RINSE OUTLET 4" CS V-1108 V-1109 AVANTech I
N C
O R
P O
R A
T E
D REV.
SIZE SCALE:
DIMENSIONS IN INCHES UNLESS SPECIFIED FILE ID.
D SHEET 6 OF 6 REV DATE DESCRIPTION DRAWN BY CHECKED BY CERTIFIED BY AVANTECH DRAWING NUMBER AVANTECH JOB NO.
A FOR REVIEW 7/17/15 VG SHEET 1, ZONE H10 DUAL MEDIA FILTERS BW TANK TO KUR-ENVI01-0001-DWG-P115, SHEET 5 30,000 GAL EFFLUENT TANK TO SHEET 1, ZONE F3 DUAL MEDIA FILTERS BW PUMPS FROM FLOOR DRAINS FLOOR DRAINS SHEET 3, ZONE C2 BIOREACTORS TRANSFER PUMPS FROM KUR-ENVI01-001-DWG-P921 1H200-1504-D 15-04 NITRATE TREATMENT TRAIN-2 PIPING & INSTRUMENTATION DIAGRAM XV 1102B V-1102B XV 1109 XV 1108 XV 1105B XV 1103B XV 1104B XV 1101B XV 1102A 4" CS XV 1104A XV 1101A XV 1103B XV 1105A XV 1107A V-1107A XV 1107B FIT 1101A FIC 1101A M
FIT 1101B FIC 1101B PIT 1101A PI 1101A PIT 1101B PI 1101B PIT 1102A PI 1102A PIT 1102B PI 1102B PDI 1100A PDI 1100B TO TK-401 B
M C