October 26, 1994 Mr. M. S. Tuckman Senior Vice President Nuclear Generation Duke Power Company P. 0. Box 1006 Charlotte, North Carolina 29201

Dear Mr. Tuckman:

SUBJECT:

OCONEE, MCGUIRE, CATAWBA -

INSERVICE INSPECTION REQUIREMENTS REQUEST FOR RELIEF, 93-GO-1 (TAC NOS. M89162, M89163, M89164, M89019, M89018, M88413, M88421)

The staff has reviewed your submittal, dated December 2, 1993, requesting relief from past weld examinations that do not meet Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code requirements. The submittal identified a non-conforming condition in that requests for relief have not been submitted for Oconee, Units 1, 2 & 3, McGuire, Units 1 and 2 and Catawba, Units 1 and 2 for weld examination coverage less than that required by the ASME Code. The submittal asked for generic relief of unspecified Class 1 and Class 2 welds and stated that you will submit the appropriate relief request for specific welds as they are identified by future inservice inspection programs.

Since you did not provide in the relief request an item-by-item list of the.

welds and inspection requirements and the technical basis to support a safety evaluation of your proposal, the staff is not able to grant your request for relief. Without a technical basis, the staff is not able to do a safety evaluation, Sincerely, Original signed by:

Herbert N. Berkow, Director 9411090122 941026 Project Directorate 11-3 PDR ADOCK 05000269 Division of Reactor Projects -

I/II P

PDR

-Office of Nuclear Reactor Regulation Docket Nos. 50-413, 50-414 50-269, 270, and 50-287 50-369, 50-370 cc:

See next page DISTRIBUTION:

D&icketIFlh0 PUBLIC PDII-3 R/F SVarga JZwolinski OGC, 0-15 B18 ACRS (10), TWF

(

BBoger, Ru I\\I~UU~

MSinkule, RH DOCUMENT NAME: G:\\M89162.LTR To receive a copy of this document, indicate in the box:

"C"

= Copy without S

attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE ILA:PD23:DRPE

[E PM:PD23:DRPf E PM:PD23:DRPL E

PM:PD23:DRPE E ID:P NAME CNorsworthy VNers RMartin I9 LWIens DATE VP /694 1/0/0494 1,,,; U./94 9z la

/694

NgREGU 0

UNITED STATES NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D. C. 20555 October 26, 1994 Mr. M. S. Tuckman Senior Vice President Nuclear Generation Duke Power Company P. 0. Box 1006 Charlotte, North Carolina 29201

Dear Mr. Tuckman:

SUBJECT:

-OCONEE, MCGUIRE, CATAWBA -

INSERVICE INSPECTION REQUIREMENTS REQUEST FOR RELIEF, 93-GO-1 (TAC NOS. M89162, M89163, M89164, M89019, M89018, M88413, M88421)

The staff has reviewed your submittal, dated December 2, 1993, requesting relief from past weld examinations that do not meet Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code requirements. The submittal identified a non-conforming condition in that requests for relief have not been submitted for Oconee, Units 1, 2 & 3, McGuire, Units 1 and 2 and Catawba, Units 1 and 2 for weld examination coverage less than that required by the ASME Code. The submittal asked for generic relief of unspecified Class 1 and Class 2 welds and stated that you will submit the appropriate relief.request for specific welds as they are identified by future inservice inspection programs.

Since you did not provide in the relief request an item-by-item list of the welds and inspection requirements and the technical basis to support a safety evaluation of your proposal, the staff is not able to grant your request for relief. Without a technical basis, the staff is not able to do a safety evaluation.

Sincerely, erbert N. Berkow, Director Project Directorate 11-3 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation Docket Nos. 50-413, 50-414 50-269, 270, and 50-287 50-369, 50-370 cc:

See next page

Duke Power Company Catawba Nuclear Station McGuire Nuclear Station Oconee Nuclear Station cc:

Dr. John M. Barry Mr. Steve Benesole Mecklenburg County Compliance Department of Environmental Duke Power Company Protection Oconee Nuclear Site 700 N Tryon Street P. 0. Box 1439 Charlotte, North Carolina 29202 Seneca, South Carolina 29679 County Manager of Mecklenburg County Mr. Robert B. Borsum 720 East Fourth Street Babcock & Wilcox Charlotte, North Carolina 28202 Nuclear Power Division Suite 525 Mr. J. E. Snyder 1700 Rockville Pike Regulatory Compliance Manager Rockville, Maryland 20852 Duke Power Company MGO1RC McGuire Nuclear Site Manager, LIS 12700 Hagers Ferry Road NUS Corporation Huntersville, North Carolina 28078 2650 McCormick Drive, 3rd Floor Clearwater, Flordia 34619-1035 Senior Resident Inspector c/o U.S. Nuclear Regulatory Senior Resident Inspector Commission U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Route 2, Box 610 Huntersville, North Carolina 28078 Seneca, South Carolina 29678 Mr. Dayne H. Brown, Director Mr. David L. Rehn Department of Environmental Vice President, Catawba Site Health and Natural Resources Duke Power Company Division of Radiation Protection 4800 Concord Road P. 0. Box 27687 York, South Carolina 29745 Raleigh, North Carolina 27611 Mr. T. C. McMeekin Office of Intergovernmental Vice President, McGuire Site Relations Duke Power Company 116 West Jones Street 12700 Hagers Ferry Road Raleigh, North Carolina 27621 Huntersville, North Carolina 28078 County Supervisor of Oconee County Elaine Wathen, Lead REP Planner Walhalla, South Carolina 27621 Division of Emergency Management 116 West Jones Street Mr. J. W. Hampton Raleigh, North Carolina 27603-1335 Vice President, Oconee Site Duke Power Company P. 0. Box 1439 Seneca, South Carolina 29679

Duke Power Company Catawba Nuclear Station McGuire Nuclear Station Oconee Nuclear Station cc:

Mr. Z. L. Taylor Regulatory Compliance Manager North Carolina Electric Membership Duke Power Company Corporation 4800 Concord Road P. 0. Box 27306 York, South Carolina 29745 Raleigh, North Carolina 27611 A. V. Carr, Esquire Saluda River Electric Cooperative, Duke Power Company Inc.

422 South Church Street P. 0. Box 929 Charlotte, North Carolina 28242 Laurens, South Carolina 29360 J. Michael McGarry, III, Esquire Senior Resident Inspector Winston and Strawn Route 2, Box 179N 1400 L Street, NW.

York, South Carolina 29745 Washington, DC 20005 Regional Administrator, Region II North Carolina Municipal Power U.S. Nuclear Regulatory Commission, Agency Number 1 101 Marietta Street, NW Suite 2900" 1427 Meadowwood Boulevard Atlanta, Georgia 30323 P. 0. Box 29513 Raleigh, North Carolina 27626 Max Batavia, Chief Bureau of Radiological Health Mr. T. Richard Puryear South Carolina Department of Health Nuclear Technical Services Manager and Environmental Control Westinghouse Electric Corporation 2600 Bull Street Carolinas District Columbia, South Carolina 29201 2709 Water Ridge Parkway, Suite 430 Charlotte, North Carolina 28217 Ms. Karen E. Long Assistant Attorney General County Manager of York County North Carolina Department of Justice York County Courthouse P. 0. Box 629 York, South Carolina 29745 Raleigh, North Carolina 27602 Richard P. Wilson, Esquire Mr. G. A. Copp Assistant Attorney General Licensing - ECO50 S.C. Attorney General's Office Duke Power Company P. 0. Box 11549 P. 0. Box 1006 Columbia, South Carolina 29211 Charlotte, North Carolina 28201-1006 Piedmont Municipal Power Agency 121 Village Drive Greer, South Carolina 29651