ML16147A560

From kanterella
Jump to navigation Jump to search
Mitigating Strategies Assessment (MSA) Report for the New Seismic Hazard Information - NEI 12-06, Appendix H, Revision 2, H.4.2 Path 2: GMRS ≪Sse with High Frequency Exceedances
ML16147A560
Person / Time
Site: Clinton 
(NPF-062)
Issue date: 05/26/2016
From: Kaegi G
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
EA-12-049, NEI 12-06, RS-16-085
Download: ML16147A560 (4)


Text

Exelon Generation ro RS-16-085 May 26, 2016 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Clinton Power Station, Unit 1 Facility Operating License No. NPF-62 NRC Docket No. 50-461 Order No. EA-12-049

Subject:

Mitigating Strategies Assessment (MSA) Report for the New Seismic Hazard Information - NEI 12-06, Appendix H, Revision 2, H.4.2 Path 2: GMRS <SSE with High Frequency Exceedances

References:

1. NEI 12-06, Revision 2, Diverse and Flexible Coping Strategies (FLEX) Implementation Guide, December 2015 (ML16005A625)
2. JLD-ISG-2012-01, Revision 1, Compliance with Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, January 22, 2016 (ML15357A163)
3. Exelon Generation Company, LLC Letter to USN RC, Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites), Response to NRC Request for Information Pursuant to 1 O CFR 50.54{f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 31, 2014 (ML14091A011)
4. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54{f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)
5. Exelon and NRC Presentation Slides for Public Meeting on Seismic Reevaluation (GMRS) dated June 17, 2014 [Exelon Slides - ML14167A053) [NRC Slides -

ML14167A320]

6. Exelon Generation Company, LLC Letter to USN RC, Supplemental Information Regarding Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites) - Response to NRC Request for Information Pursuant to 1 O CFR 50.54(f)

Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated August 21, 2014 (ML14234A124)

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page2

7. NRG Letter, Final Screening and Prioritization Results for Limerick, Clinton, Salem, Surry, and Quad Cities Regarding Seismic Hazard Reevaluation for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated October 3, 2014(ML14258A043)
8. NRG Letter, Clinton Power Station, Unit 1 - Staff Assessment of Information Provided Pursuant to Title 1 O of the Code of Federal Regulations Part 50, Section 50.54(f),

Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated October 19, 2015 (ML15281A226)

9. NRG Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated October 27, 2015 (ML15194A015)
10. Exelon Generation Company, LLC Letter to USNRC, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRG Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated November 30, 2015 (ML15335A389)
11. NRG Letter, Staff Review of High Frequency Confirmation Associated with Reevaluated Seismic Hazard in Response to March 12, 2012 50.54(f) Request for Information, dated February 18, 2016 (ML15364A544)
12. NEI Letter, Request for NRG Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),

dated July 30, 2015 (ML15223A100/ML15223A102)

13. NRG Letter to NEI, Endorsement of Electric Power Research Institute Final Draft Report 3002004396, "High Frequency Program: Application Guidance for Functional Confirmation and Fragility, dated September 17, 2015 (ML15218A569)

The purpose of this letter is to provide the results of the assessment for Clinton Power Station (CPS), Unit 1 to determine if the FLEX strategies developed, implemented and maintained in accordance with NRG Order EA-12-049 can be implemented considering the impacts of the reevaluated seismic hazard. The assessment was performed in accordance with the guidance provided in Appendix Hof NEI 12-06 Revision 2 (Reference 1) which was endorsed by the NRG (Reference 2).

The Mitigating Strategies Seismic Hazard Information (MSSHI) is the licensee's reevaluated seismic hazard information at the CPS, Unit 1 site, developed using Probabilistic Seismic Hazard Analysis (PSHA). The MSSHI includes a performance-based Ground Motion Response Spectrum (GMRS), Uniform Hazard Response Spectra (UHAS) at various annual probabilities of exceedance, and a family of seismic hazard curves at various frequencies and fractiles developed at the CPS, Unit 1 site control point elevation. Exelon Generation Company, LLC (EGG) submitted the reevaluated seismic hazard information including the UHRS, GMRS and the hazard curves to the NRG in Reference 3 which included a commitment to perform a High Frequency (HF) Confirmation. Subsequently, the NRC's Screening and Prioritization letter (Reference 4) conditionally required CPS to perform a Seismic Probabilistic Risk Assessment

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page 3 (SPRA), an Expedited Seismic Evaluation Process (ESEP) evaluation and a Spent Fuel Pool (SFP) evaluation in addition to the previous Reference 3 HF Confirmation commitment. EGC submitted supplemental information in References 5 and 6 in support of an SPRA "screen-out",

and as a result the NRC in Reference 7 retracted the requirement for CPS to perform SPRA, ESEP and SFP evaluations and reaffirmed the requirement for an HF Confirmation evaluation.

Reference 8 reaffirmed the Reference 7 required evaluations for CPS and also confirmed the acceptability of the Reference 3 seismic hazard for use with all Near-Term Task Force (NTTF)

Recommendation 2.1 seismic evaluations for CPS based on the adequacy of its characterization of the reevaluated seismic hazard for CPS. Additionally, the NRC Final Determination Letter (Reference 9) confirmed that only an HF Confirmation evaluation is required for CPS.

EGC submitted a response for the NTTF Recommendation 2.1 seismic HF evaluation (Reference 10) in accordance with the screening allowance of EPRI 3002004396, Section 3.1.2 for limited HF exceedance (Reference 12, endorsed by NRC in Reference 13). The NRC subsequently accepted the closure of CPS HF Confirmation per Reference 11.

Consistent with Section H.4.2 of Reference 1, the CPS, Unit 1 site GMRS is bounded by the Safe Shutdown Earthquake (SSE) spectrum at frequencies between 1 to 1 O Hz. In the frequency range above 1 O Hz, the GMRS exceeds the SSE spectrum. References 1 O and 11 provide the HF Confirmation assessment that was performed for CPS, Unit 1 and NRC concurrence, respectively. For the CPS, Unit 1 site, the GMRS to SSE exceedance at frequencies greater than 1 O Hz qualifies as a minimal high frequency exceedance defined in Section 3.1.2 of EPRI 3002004396 (Reference 12), as endorsed by the NRC (Reference 13),

and is considered inconsequential based on the requirements contained in Section H.4.2 of Reference 1. Therefore, the FLEX strategies for CPS, Unit 1 can be implemented as designed and no further seismic evaluations or mitigating strategies assessments are necessary.

This letter contains no new regulatory commitments and no revision to existing regulatory commitments.

If you have any questions regarding this submittal, please contact David P. Helker at (610) 765-5525.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 26th day of May 2016.

Respectfully submitted, AT¥ Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page4 cc:

NRC Regional Administrator - Region Ill NRC Project Manager, NRA - Clinton Power Station NRC Senior Resident Inspector - Clinton Power Station Mr. Nicholas J. DiFrancesco, NRR/JLD/PPSD/HMB, NRC Mr. John P. Boska, NRR/JLD/JOMB, NRC Illinois Emergency Management Agency-Division of Nuclear Safety

Exelon Generation ro RS-16-085 May 26, 2016 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Clinton Power Station, Unit 1 Facility Operating License No. NPF-62 NRC Docket No. 50-461 Order No. EA-12-049

Subject:

Mitigating Strategies Assessment (MSA) Report for the New Seismic Hazard Information - NEI 12-06, Appendix H, Revision 2, H.4.2 Path 2: GMRS <SSE with High Frequency Exceedances

References:

1. NEI 12-06, Revision 2, Diverse and Flexible Coping Strategies (FLEX) Implementation Guide, December 2015 (ML16005A625)
2. JLD-ISG-2012-01, Revision 1, Compliance with Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, January 22, 2016 (ML15357A163)
3. Exelon Generation Company, LLC Letter to USN RC, Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites), Response to NRC Request for Information Pursuant to 1 O CFR 50.54{f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 31, 2014 (ML14091A011)
4. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54{f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)
5. Exelon and NRC Presentation Slides for Public Meeting on Seismic Reevaluation (GMRS) dated June 17, 2014 [Exelon Slides - ML14167A053) [NRC Slides -

ML14167A320]

6. Exelon Generation Company, LLC Letter to USN RC, Supplemental Information Regarding Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites) - Response to NRC Request for Information Pursuant to 1 O CFR 50.54(f)

Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated August 21, 2014 (ML14234A124)

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page2

7. NRG Letter, Final Screening and Prioritization Results for Limerick, Clinton, Salem, Surry, and Quad Cities Regarding Seismic Hazard Reevaluation for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident, dated October 3, 2014(ML14258A043)
8. NRG Letter, Clinton Power Station, Unit 1 - Staff Assessment of Information Provided Pursuant to Title 1 O of the Code of Federal Regulations Part 50, Section 50.54(f),

Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated October 19, 2015 (ML15281A226)

9. NRG Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 1 O of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated October 27, 2015 (ML15194A015)
10. Exelon Generation Company, LLC Letter to USNRC, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRG Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated November 30, 2015 (ML15335A389)
11. NRG Letter, Staff Review of High Frequency Confirmation Associated with Reevaluated Seismic Hazard in Response to March 12, 2012 50.54(f) Request for Information, dated February 18, 2016 (ML15364A544)
12. NEI Letter, Request for NRG Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),

dated July 30, 2015 (ML15223A100/ML15223A102)

13. NRG Letter to NEI, Endorsement of Electric Power Research Institute Final Draft Report 3002004396, "High Frequency Program: Application Guidance for Functional Confirmation and Fragility, dated September 17, 2015 (ML15218A569)

The purpose of this letter is to provide the results of the assessment for Clinton Power Station (CPS), Unit 1 to determine if the FLEX strategies developed, implemented and maintained in accordance with NRG Order EA-12-049 can be implemented considering the impacts of the reevaluated seismic hazard. The assessment was performed in accordance with the guidance provided in Appendix Hof NEI 12-06 Revision 2 (Reference 1) which was endorsed by the NRG (Reference 2).

The Mitigating Strategies Seismic Hazard Information (MSSHI) is the licensee's reevaluated seismic hazard information at the CPS, Unit 1 site, developed using Probabilistic Seismic Hazard Analysis (PSHA). The MSSHI includes a performance-based Ground Motion Response Spectrum (GMRS), Uniform Hazard Response Spectra (UHAS) at various annual probabilities of exceedance, and a family of seismic hazard curves at various frequencies and fractiles developed at the CPS, Unit 1 site control point elevation. Exelon Generation Company, LLC (EGG) submitted the reevaluated seismic hazard information including the UHRS, GMRS and the hazard curves to the NRG in Reference 3 which included a commitment to perform a High Frequency (HF) Confirmation. Subsequently, the NRC's Screening and Prioritization letter (Reference 4) conditionally required CPS to perform a Seismic Probabilistic Risk Assessment

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page 3 (SPRA), an Expedited Seismic Evaluation Process (ESEP) evaluation and a Spent Fuel Pool (SFP) evaluation in addition to the previous Reference 3 HF Confirmation commitment. EGC submitted supplemental information in References 5 and 6 in support of an SPRA "screen-out",

and as a result the NRC in Reference 7 retracted the requirement for CPS to perform SPRA, ESEP and SFP evaluations and reaffirmed the requirement for an HF Confirmation evaluation.

Reference 8 reaffirmed the Reference 7 required evaluations for CPS and also confirmed the acceptability of the Reference 3 seismic hazard for use with all Near-Term Task Force (NTTF)

Recommendation 2.1 seismic evaluations for CPS based on the adequacy of its characterization of the reevaluated seismic hazard for CPS. Additionally, the NRC Final Determination Letter (Reference 9) confirmed that only an HF Confirmation evaluation is required for CPS.

EGC submitted a response for the NTTF Recommendation 2.1 seismic HF evaluation (Reference 10) in accordance with the screening allowance of EPRI 3002004396, Section 3.1.2 for limited HF exceedance (Reference 12, endorsed by NRC in Reference 13). The NRC subsequently accepted the closure of CPS HF Confirmation per Reference 11.

Consistent with Section H.4.2 of Reference 1, the CPS, Unit 1 site GMRS is bounded by the Safe Shutdown Earthquake (SSE) spectrum at frequencies between 1 to 1 O Hz. In the frequency range above 1 O Hz, the GMRS exceeds the SSE spectrum. References 1 O and 11 provide the HF Confirmation assessment that was performed for CPS, Unit 1 and NRC concurrence, respectively. For the CPS, Unit 1 site, the GMRS to SSE exceedance at frequencies greater than 1 O Hz qualifies as a minimal high frequency exceedance defined in Section 3.1.2 of EPRI 3002004396 (Reference 12), as endorsed by the NRC (Reference 13),

and is considered inconsequential based on the requirements contained in Section H.4.2 of Reference 1. Therefore, the FLEX strategies for CPS, Unit 1 can be implemented as designed and no further seismic evaluations or mitigating strategies assessments are necessary.

This letter contains no new regulatory commitments and no revision to existing regulatory commitments.

If you have any questions regarding this submittal, please contact David P. Helker at (610) 765-5525.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 26th day of May 2016.

Respectfully submitted, AT¥ Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC

U.S. Nuclear Regulatory Commission Mitigating Strategies Seismic Hazard Assessment May 26, 2016 Page4 cc:

NRC Regional Administrator - Region Ill NRC Project Manager, NRA - Clinton Power Station NRC Senior Resident Inspector - Clinton Power Station Mr. Nicholas J. DiFrancesco, NRR/JLD/PPSD/HMB, NRC Mr. John P. Boska, NRR/JLD/JOMB, NRC Illinois Emergency Management Agency-Division of Nuclear Safety