RS-15-287, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from

From kanterella
(Redirected from ML15335A389)
Jump to navigation Jump to search
High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from
ML15335A389
Person / Time
Site: Clinton 
(NPF-062)
Issue date: 11/30/2015
From: Kaegi G
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-15-287
Download: ML15335A389 (6)


Text

^~ ExeLon Generation.

RS-15-287

10 CFR 50.54(f)

November 30, 2015 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike, Rockville, MD 20852 Clinton Power Station, Unit 1 Facility Operating License No. NFP-62 NRC Docket No. 50-461

Subject:

High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident

References:

1. NRC Letter, Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2012 (ML12053A340)
2. NRC Letter, Electric Power Research Institute Report 3002000704, "Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," As An Acceptable Alternative to the March 12, 2012, Information Request for Seismic Reevaluations, dated May 7, 2013 (ML13106A331)
3. NEI Letter, Final Draft of Industry Seismic Evaluation Guidance (EPRI 1025287), dated November 27, 2012 (ML12333A168 and ML12333A170)
4. NRC Letter, Endorsement of Electric Power Research Institute Final Draft Report 1025287, "Seismic Evaluation Guidance", dated February 15, 2013 (ML12319A074)
5. Exelon Generation Company, LLC letter to NRC, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10CFR50.54(f)

Regarding Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Clinton Power Station, Unit 1, dated March 31, 2014 (RS-14-066)

6. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 30, 2015 Page 2

7. NRC Letter, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluation for Operating Reactors in the Central and Eastern United States, dated May 21, 2014 (ML14136A126)
8. NEI Letter, Request for NRC Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),

dated July 30, 2015 (M L 1 5223A 1 OO/M L 1 5223A 102)

9. NRC Letter, September 17, 2015 to NEI: Endorsement of Electric Power Research Institute Final Draft Report 3002004396: "High Frequency Program: Application Guidance for Functional Confirmation and Fragility" (ML15218A569)
10. NRC Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident, dated October 27, 2015 (ML15194A015)

On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a Request for Information per 10 CFR 50.54(f) (Reference 1) to all power reactor licensees. The required response section of Enclosure 1 of Reference 1 indicated that licensees should provide a Seismic Hazard Evaluation and Screening Report within 1.5 years from the date of the letter for Central and Eastern United States (CEUS) nuclear power plants. By NRC letter dated May 7, 2013 (Reference 2), the date to submit the report was extended to March 31, 2014.

By letter dated May 9, 2014 (Reference 6), the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation submittal for Clinton Power Station, Unit 1 (Reference 5). In accordance with the screening, prioritization, and implementation details report (SPID) (References 3 and 4), and Augmented Approach guidance (Reference 2),

the reevaluated seismic hazard is used to determine if additional seismic risk evaluations are warranted for a plant. Specifically, the reevaluated horizontal ground motion response spectrum (GIVIRS) at the control point elevation is compared to the existing safe shutdown earthquake (SSE) or Individual Plant Examination for External Events (IPEEE) High Confidence of Low Probability of Failure (HCLPF) Spectrum (IHS) to determine if a plant is required to perform a high frequency confirmation evaluation. As noted in the May 9, 2014 letter from the NRC (Reference 6) on page 2 of Enclosure 2, Clinton Power Station, Unit 1 is to conduct a limited scope High Frequency Evaluation (Confirmation).

Within the May 9, 2014 letter (Reference 6), the NRC acknowledged that these limited scope evaluations will require additional development of the assessment process. By Reference 8, the Nuclear Energy Institute (NEI) submitted an Electric Power Research Institute (EPRI) report entitled, High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396) for NRC review and endorsement. NRC endorsement was provided by Reference 9. Reference 10 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities. This submittal is provided in accordance with Reference 10, Table 1 a, to address the High Frequency Evaluation information request for Clinton Power Station, Unit 1.

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 30, 2015 Page 3 The High Frequency Confirmation for Clinton Power Station, Unit 1, provided in the attachment to this letter, shows that the GIVIRS exceedance area between the control point GIVIRS and SSE is "on the order of 10% or less" (Reference 8, Section 3.1.2) over the frequency range of exceedance. As such, the GIVIRS exceedances are consistent with the criteria identified in Section 3.1.2 of Reference 8. Therefore, no additional evaluation is necessary. The attachment to this letter provides the SSE and GIVIRS information from Reference 5.

This transmittal completes the scope of work described in Section 4.2 of Reference 5, for Clinton Power Station, Unit 1.

This letter contains no new regulatory commitments and closes the associated regulatory commitment contained in Reference 5 for Clinton Power Station, Unit 1.

If you have any questions regarding this report, please contact Ronald Gaston at 630-657-3359.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 30th day of November 2015.

Respectfully submitted, Glen T. Kaegi Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC

Attachment:

Clinton Power Station, Unit 1 GIVIRS and SSE Supporting Information cc:

Regional Administrator - NRC Region III NRC Senior Resident Inspector Clinton Power Station NRC Project Manager, NRR Clinton Power Station Mr. Nicholas DiFrancesco, NRR/JLD/JHMB, NRC

Attachment Clinton Power Station, Unit 1 GMRS and SSE Supporting Information (2 Pages)

Table 1 - Clinton Power Station, Unit 1 SSE and GMRS Data SSE

GMRS Freq Accel Freq Accel (Hz)

(g)

(Hz)

(g) 0.1 2.43E-02 0.125 3.04E-02 0.15 3.65E-02 0.2 4.86E-02 0.25 6.08E-02 0.3 7.30E-02 0.35 0.161 0.35 8.51 E-02 0.4 9.73E-02 0.5 0.216 0.5 1.22E-01 0.6 1.49E-01 0.7 1.70E-01 0.8 1.92E-01 0.9 2.14E-01 1

0.383 1

2.32E-01 1.25 0.461 1.25 2.77E-01 1.5 3.15E-01 2

0.677 2

3.70E-01 2.5 0.814 2.5 3.89E-01 3

0.794 3

4.38E-01 3.5 4.74E-01 4

0.761 4

5.17E-01 5

0.737 5

5.75E-01 6

0.719 6

5.54E-01 7

0.703 7

5.61 E-01 8

0.690 8

5.83E-01 9

0.679 9

5.54E-01 10 0.628 10 5.06E-01 12 0.549 12.5 4.61 E-01 12.5 0.532 15 4.27E-01 13 0.517 20

-3.68E-01 15 0.465 25 3.33E-01 20 0.376 30 3.07E-01 25 0.319 35 2.91 E-01 28 0.293 40 2.81 E-01 30 0.279 50 2.70E-01 33 0.260 60 2.65E-01 35 0.260 70 2.63E-01 40 0.260 80 2.61 E-01 50 0.260 90 2.61 E-01 100 0.260 100 2.60E-01 Page 1 of 2

Figure 1 Clinton Power Station, Unit 1 GMRS to SSE Comparison

~ SSE

~ GMRS 0.9 0.8 0.7 c

1-0

0.6 a~

0.5 cc 00 Q

0.4 0.3 000 Or 0.2

';000 00 00 00/

400 0.1 000 0 0

0.1

1

10

100 Frequency (Hz)

Page 2 of 2

^~ ExeLon Generation.

RS-15-287

10 CFR 50.54(f)

November 30, 2015 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike, Rockville, MD 20852 Clinton Power Station, Unit 1 Facility Operating License No. NFP-62 NRC Docket No. 50-461

Subject:

High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident

References:

1. NRC Letter, Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2012 (ML12053A340)
2. NRC Letter, Electric Power Research Institute Report 3002000704, "Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic," As An Acceptable Alternative to the March 12, 2012, Information Request for Seismic Reevaluations, dated May 7, 2013 (ML13106A331)
3. NEI Letter, Final Draft of Industry Seismic Evaluation Guidance (EPRI 1025287), dated November 27, 2012 (ML12333A168 and ML12333A170)
4. NRC Letter, Endorsement of Electric Power Research Institute Final Draft Report 1025287, "Seismic Evaluation Guidance", dated February 15, 2013 (ML12319A074)
5. Exelon Generation Company, LLC letter to NRC, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10CFR50.54(f)

Regarding Recommendation 2.1 of Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Clinton Power Station, Unit 1, dated March 31, 2014 (RS-14-066)

6. NRC Letter, Screening and Prioritization Results Regarding Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Re-evaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated May 9, 2014 (ML14111A147)

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 30, 2015 Page 2

7. NRC Letter, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluation for Operating Reactors in the Central and Eastern United States, dated May 21, 2014 (ML14136A126)
8. NEI Letter, Request for NRC Endorsement of High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396),

dated July 30, 2015 (M L 1 5223A 1 OO/M L 1 5223A 102)

9. NRC Letter, September 17, 2015 to NEI: Endorsement of Electric Power Research Institute Final Draft Report 3002004396: "High Frequency Program: Application Guidance for Functional Confirmation and Fragility" (ML15218A569)
10. NRC Letter, Final Determination of Licensee Seismic Probabilistic Risk Assessments Under the Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendation 2.1 "Seismic" of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident, dated October 27, 2015 (ML15194A015)

On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued a Request for Information per 10 CFR 50.54(f) (Reference 1) to all power reactor licensees. The required response section of Enclosure 1 of Reference 1 indicated that licensees should provide a Seismic Hazard Evaluation and Screening Report within 1.5 years from the date of the letter for Central and Eastern United States (CEUS) nuclear power plants. By NRC letter dated May 7, 2013 (Reference 2), the date to submit the report was extended to March 31, 2014.

By letter dated May 9, 2014 (Reference 6), the NRC transmitted the results of the screening and prioritization review of the seismic hazards reevaluation submittal for Clinton Power Station, Unit 1 (Reference 5). In accordance with the screening, prioritization, and implementation details report (SPID) (References 3 and 4), and Augmented Approach guidance (Reference 2),

the reevaluated seismic hazard is used to determine if additional seismic risk evaluations are warranted for a plant. Specifically, the reevaluated horizontal ground motion response spectrum (GIVIRS) at the control point elevation is compared to the existing safe shutdown earthquake (SSE) or Individual Plant Examination for External Events (IPEEE) High Confidence of Low Probability of Failure (HCLPF) Spectrum (IHS) to determine if a plant is required to perform a high frequency confirmation evaluation. As noted in the May 9, 2014 letter from the NRC (Reference 6) on page 2 of Enclosure 2, Clinton Power Station, Unit 1 is to conduct a limited scope High Frequency Evaluation (Confirmation).

Within the May 9, 2014 letter (Reference 6), the NRC acknowledged that these limited scope evaluations will require additional development of the assessment process. By Reference 8, the Nuclear Energy Institute (NEI) submitted an Electric Power Research Institute (EPRI) report entitled, High Frequency Program: Application Guidance for Functional Confirmation and Fragility Evaluation (EPRI 3002004396) for NRC review and endorsement. NRC endorsement was provided by Reference 9. Reference 10 provided the NRC final seismic hazard evaluation screening determination results and the associated schedules for submittal of the remaining seismic hazard evaluation activities. This submittal is provided in accordance with Reference 10, Table 1 a, to address the High Frequency Evaluation information request for Clinton Power Station, Unit 1.

U.S. Nuclear Regulatory Commission Seismic Hazard 2.1 High Frequency Supplement November 30, 2015 Page 3 The High Frequency Confirmation for Clinton Power Station, Unit 1, provided in the attachment to this letter, shows that the GIVIRS exceedance area between the control point GIVIRS and SSE is "on the order of 10% or less" (Reference 8, Section 3.1.2) over the frequency range of exceedance. As such, the GIVIRS exceedances are consistent with the criteria identified in Section 3.1.2 of Reference 8. Therefore, no additional evaluation is necessary. The attachment to this letter provides the SSE and GIVIRS information from Reference 5.

This transmittal completes the scope of work described in Section 4.2 of Reference 5, for Clinton Power Station, Unit 1.

This letter contains no new regulatory commitments and closes the associated regulatory commitment contained in Reference 5 for Clinton Power Station, Unit 1.

If you have any questions regarding this report, please contact Ronald Gaston at 630-657-3359.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 30th day of November 2015.

Respectfully submitted, Glen T. Kaegi Director - Licensing & Regulatory Affairs Exelon Generation Company, LLC

Attachment:

Clinton Power Station, Unit 1 GIVIRS and SSE Supporting Information cc:

Regional Administrator - NRC Region III NRC Senior Resident Inspector Clinton Power Station NRC Project Manager, NRR Clinton Power Station Mr. Nicholas DiFrancesco, NRR/JLD/JHMB, NRC

Attachment Clinton Power Station, Unit 1 GMRS and SSE Supporting Information (2 Pages)

Table 1 - Clinton Power Station, Unit 1 SSE and GMRS Data SSE

GMRS Freq Accel Freq Accel (Hz)

(g)

(Hz)

(g) 0.1 2.43E-02 0.125 3.04E-02 0.15 3.65E-02 0.2 4.86E-02 0.25 6.08E-02 0.3 7.30E-02 0.35 0.161 0.35 8.51 E-02 0.4 9.73E-02 0.5 0.216 0.5 1.22E-01 0.6 1.49E-01 0.7 1.70E-01 0.8 1.92E-01 0.9 2.14E-01 1

0.383 1

2.32E-01 1.25 0.461 1.25 2.77E-01 1.5 3.15E-01 2

0.677 2

3.70E-01 2.5 0.814 2.5 3.89E-01 3

0.794 3

4.38E-01 3.5 4.74E-01 4

0.761 4

5.17E-01 5

0.737 5

5.75E-01 6

0.719 6

5.54E-01 7

0.703 7

5.61 E-01 8

0.690 8

5.83E-01 9

0.679 9

5.54E-01 10 0.628 10 5.06E-01 12 0.549 12.5 4.61 E-01 12.5 0.532 15 4.27E-01 13 0.517 20

-3.68E-01 15 0.465 25 3.33E-01 20 0.376 30 3.07E-01 25 0.319 35 2.91 E-01 28 0.293 40 2.81 E-01 30 0.279 50 2.70E-01 33 0.260 60 2.65E-01 35 0.260 70 2.63E-01 40 0.260 80 2.61 E-01 50 0.260 90 2.61 E-01 100 0.260 100 2.60E-01 Page 1 of 2

Figure 1 Clinton Power Station, Unit 1 GMRS to SSE Comparison

~ SSE

~ GMRS 0.9 0.8 0.7 c

1-0

0.6 a~

0.5 cc 00 Q

0.4 0.3 000 Or 0.2

';000 00 00 00/

400 0.1 000 0 0

0.1

1

10

100 Frequency (Hz)

Page 2 of 2