Charles R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.

40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35242 Tel 205.992.7872 Fax 205.992.7601 SOUTHERN<<\\

NUCLEAR A SOUTHERN COMPANY MAY 2 6 2016 NL-16-0739 10 CFR 50.90 Docket Nos.: 50-321 50-348 50-424 52-025 50-366 50-364 50-425 52-026 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Southern Nuclear Operating Company Joseph M. Farley Nuclear Plant Units 1 and 2; Edwin I. Hatch Nuclear Plant Units 1 and 2; Vogtle Electric Generating Plant Units 1 and 2; Vogtle Electric Generating Plant Units 3 and 4 Corrected Response to Second Request for Additional Information Regarding Standard Emergency Plan Ladies and Gentlemen:

By letter dated August 31, 2015 (NL-15-1392), Southern Nuclear Operating Company (SNC) requested license amendments (LARs) for approval of a fleet standard emergency plan for Edwin I. Hatch Nuclear Plant Units 1 and 2, Joseph M. Farley Nuclear Plant Units 1 and 2, and Vogtle Electric Generating Plant Units 1, 2, 3 and 4 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML15246A045). By letter dated February 4, 2016, the U.S. Nuclear Regulatory Commission (NRC) issued its second Requests for Additional Information (RAis) (ADAMS Accession Number ML16029A035).

By letter dated April a, 2016 (ADAMS Accession Number ML16105A194), SNC responded to the second set of RAis. In this response, SNC provided an incorrect Table 2.2.A of the Vogtle 3&4 Annex in response to RAI-VEGP3&4-1. SNC has performed a review of the Vogtle 3&4 On-Shift Staffing Analysis and provided a corrected submittal of the assessment of emergency response staffing in accordance with VEGP 3&4 License Condition 2.D.(12)(d) per SNC letter ND 057 4 on May 13, 2016. (ADAMS Accession Numbers [ML16134A463, ML16134A464]). In order to conform the response to the second set of RAis with the revised Vogtle 3&4 On-Shift Staffing Analysis, SNC has enclosed a revised Table 2.2.A. An additional conforming change to the Vogtle 3&4 Annex will be submitted with SNC's response to the 3rd set of RAis due by June 13, 2016.

SNC is notifying the states of Georgia and Alabama of this response to the NRC RAJ by transmitting a copy of this letter and enclosures to the designated state official.

This letter contains no new regulatory commitments. If you have any questions, please contact Ken McElroy at (205) 992-7369.

U.S. Nuclear Regulatory Commission NL-16-0739 Page 2 Mr. C. A. Pierce states he is the Regulatory Affairs Director for Southern Nuclear Operating Company, is authorized to execute this oath on behalf of Southern Nuclear Operating Company and, to the best of his knowledge and belief, the facts set forth in this letter are true.

Ret~~:y~d, C. R. Pierce Regulatory Affairs Director CRP/EFB/Iac d before me this ;tc.

,2016.

My commission expires: /6, ~

  • J_() I 1 -Table 2.2.A-Vogtle Electric Generating Plant On-Shift Staffing cc:

Nuclear Regulatory Commission Mr. W. M. Dean, Director of the Office of Nuclear Reactor Regulations Ms. C. Haney, Regional Administrator Mr. M. Delligatti, Deputy Division Director, DNRL Mr. L. Burkhart, Br~nch Chief, LB4, DNRL Mr. M. E. Ernstes, Branch Chief, DRP, All Mr. A. E. Martin, NRR Senior Project Manager-Vogtle 1 & 2 Mr. S. A. Williams, NRR Project Manager-Farley Mr. M. D. Orenak, NRR Project Manager-Hatch Mr. C. Patel, NRO Project Manager-Vogtle 3 & 4 Mr. P. Kallan, Senior Project Manager-Vogtle 3 & 4 Mr. B. M. Bavol, Project Manager-Vogtle 3 & 4 Ms. A. Reyes, Project Manager-Vogtle 3 & 4 Ms. M. A. Sutton, Project Manager-Vogtle 3 & 4 Mr. G. Khouri, Senior Project Inspector-Vogtle 3 & 4 Mr. D. H. Hardage, Senior Resident Inspector-Hatch Mr. A. M. Alen, Resident Inspector-Vogtle 1 & 2 Mr. P. K. Niebaum, Senior Resident Inspector-Farley Mr. J. D. Fuller, Senior Resident Inspector, Vogtle 3 & 4 Ms. S. Temple, Resident Inspector-Vogtle 3 & 4 State of Alabama Dr. T. M. Miller, State Health Officer, Department of Public Health State of Georgia Mr. J. H. Turner, Director-Environmental Protection Division

U.S. Nuclear Regulatory Commission NL-16-0739 Page3 Blind Copy List (without enclosures unless noted):

Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bast, Executive Vice President & Chief Nuclear Officer Mr. M.D. Rauckhorst, Construction V.P.- Vogtle 3-4 Mr. D. H. Jones, Vice President Technical Compliance-Voqtle 3-4 Ms. K. D. Fill-Vice President-Operational Readiness Ms. C. A. Gayheart, Vice President - Farley Mr. D. R. Vineyard, Vice President-Hatch Mr. B. K. Taber, Vice President-Vogtie 1-2 Mr. D. R. Madison, Vice President-Aeet Operations Mr. M. D. Meier, Vice President-Regulatory Affairs Mr. B. J. Adams, Vice President-Engineering Mr. C. R. Pierce, Regulatory Affairs Director - Fleet Mr. B. H. WhiUey, Regulatory Affairs Director-Nuclear Development Mr. M. J. Vox, Regulatory Affairs Director-Vogtie 3-4 Ms. B. L. Taylor, Regulatory Affairs Manager-Farley Mr. G. L. Johnson, Regulatory Affairs Manager-Hatch Mr. G. W. Gunn, Regulatory Affairs Manager-Vogtle 1-2 Mr. W. A. Sparkman, Licensing Manager-Nuclear Development Mr. T. W. Yelverton-Commercial Director-Vogtle 3-4 Mr. D. L. Fulton - Nuclear Development Environmental Manager Mr. J. C. Harrelson-Project Manager Mr. T. R. Takats-Engineering Supervisor Mr. J.P. Redd-Licensing Supervisor Mr. J. G. Hall-Emergency Preparedness Supervisor RTYPEs: CFA04.054; CHA02.004; CVC7000; VND.LI.LOO (w/enclosures)

Ale AR.01.02.06 (w/enclosures)

Oglethorpe Power Corporation Mr. M. W. Price Mr. Ms. K. T. Haynes Ms. A Whaley Municioal Electric Authorltv of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros WECTEC Ms. K. Stoner Mr. C. A. Castell Westinghouse Electric Comoany. LLC Mr. R. Easterling Mr. J. W. Crenshaw Mr. C. D. Churchman Mr. L. Woodcock Mr. P. A. Russ Mr. G. F. Couture Mr. M. Y. Shaqqo Other Mr. J. E. Hesler, Bechtel Power Corporation Ms. L.A. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Ms. S. W. Kemizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham Mr. R Grumbir, APOG Ms. A. RiceMr. J. R. Bouknight, South Carolina Electric & Gas Company Mr. D. Kersey, South Carolina Electric & Gas Company Mr. B. Kitchen, Duke Energy Mr. S. Franzone, Florida Power & Light

ATTACHMENT1 Vogtle Electric Generating Plant On-Shift Staffing (Units 3 and 4)

Table 2.2.A

SNC Response to 2nd Set of RAis Standard E-Pian LAR Attach. 1 Table 2.2.A-Vogtle Electric Generating Plant On-Shift Staffing Vogtle 3 & 4 Major Major Tasks Position On-Shift On-Shift Functional Unit3 Unit4 Area Emergency Shift Manager (SM)/

1 1

Direction and Emergency Director Control (ED)

Plant Shift Supervisor (SAO) 1 1

Operations and Assessment of Shift Support 1

Operational Supervisor /Fire Aspects Brigade(SRO/FBL)

Licensed Operator 1

(SAO or RO)

Reactor Operators 2

2 (RO)

System Operators (SO) 2 2

System Operators I Fire 4

Brigade {SO/FBM)

Plant System Technical Support Shift Technical Advisor Note 1 Engineering, Repair and Corrective Actions Notification/

Notify licensee, State Licensed Operator Note 1 Communication local and Federal (SAO or RO) personnel & maintain communication Radiological Offsite Dose Chemistry Technician Accident Assessment Assessment In-plant surveys RP Technician 1

and Support of Operational Offsite Surveys Onsite RP Technician Accident (out-of-plant)

Assessment Protective Radiation Protection:

RP Technician 1

Actions

a. Access Control
b. RP Coverage for repair, corrective actions, search and rescue first-aid &

firefighting

c. Personnel monitoring
d. Dosimetry Chemistry/Radio-Chemistry Technician 1

chemistry Page 1 Shared Resources with Unit 1&2 1 NOte ;j 1

NOte ;j 1

Note ;j 1

1

SNC Response to 2nd Set of RAis Standard E-Pian LAR Attach. 1 Plant System Repair and Corrective Engineering, Actions Repair and Corrective Actions Firefighting Rescue Operations and First Aid Plant Access and Personnel Accountability Maintenance Supervisor Mechanic Electrician I & C Technician Total:

Fire Brigade Note2 Rescue Operations/Fir stAid Note1 Security Note 1 - May be provided by shift personnel assigned other functions 21 5

Sec Plan Note 2 - Fire Brigade made up of Fire Brigade Leader (SSS) and 4 System Operators Note 3 - Vogtle Unit 1 &2 resource may be used for events impacting multiple units Page2 1

1 1

1 9

2

Charles R. Pierce Regulatory Affairs Director Southern Nuclear Operating Company, Inc.

40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35242 Tel 205.992.7872 Fax 205.992.7601 SOUTHERN<<\\

NUCLEAR A SOUTHERN COMPANY MAY 2 6 2016 NL-16-0739 10 CFR 50.90 Docket Nos.: 50-321 50-348 50-424 52-025 50-366 50-364 50-425 52-026 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Southern Nuclear Operating Company Joseph M. Farley Nuclear Plant Units 1 and 2; Edwin I. Hatch Nuclear Plant Units 1 and 2; Vogtle Electric Generating Plant Units 1 and 2; Vogtle Electric Generating Plant Units 3 and 4 Corrected Response to Second Request for Additional Information Regarding Standard Emergency Plan Ladies and Gentlemen:

By letter dated August 31, 2015 (NL-15-1392), Southern Nuclear Operating Company (SNC) requested license amendments (LARs) for approval of a fleet standard emergency plan for Edwin I. Hatch Nuclear Plant Units 1 and 2, Joseph M. Farley Nuclear Plant Units 1 and 2, and Vogtle Electric Generating Plant Units 1, 2, 3 and 4 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML15246A045). By letter dated February 4, 2016, the U.S. Nuclear Regulatory Commission (NRC) issued its second Requests for Additional Information (RAis) (ADAMS Accession Number ML16029A035).

By letter dated April a, 2016 (ADAMS Accession Number ML16105A194), SNC responded to the second set of RAis. In this response, SNC provided an incorrect Table 2.2.A of the Vogtle 3&4 Annex in response to RAI-VEGP3&4-1. SNC has performed a review of the Vogtle 3&4 On-Shift Staffing Analysis and provided a corrected submittal of the assessment of emergency response staffing in accordance with VEGP 3&4 License Condition 2.D.(12)(d) per SNC letter ND 057 4 on May 13, 2016. (ADAMS Accession Numbers [ML16134A463, ML16134A464]). In order to conform the response to the second set of RAis with the revised Vogtle 3&4 On-Shift Staffing Analysis, SNC has enclosed a revised Table 2.2.A. An additional conforming change to the Vogtle 3&4 Annex will be submitted with SNC's response to the 3rd set of RAis due by June 13, 2016.

SNC is notifying the states of Georgia and Alabama of this response to the NRC RAJ by transmitting a copy of this letter and enclosures to the designated state official.

This letter contains no new regulatory commitments. If you have any questions, please contact Ken McElroy at (205) 992-7369.

U.S. Nuclear Regulatory Commission NL-16-0739 Page 2 Mr. C. A. Pierce states he is the Regulatory Affairs Director for Southern Nuclear Operating Company, is authorized to execute this oath on behalf of Southern Nuclear Operating Company and, to the best of his knowledge and belief, the facts set forth in this letter are true.

Ret~~:y~d, C. R. Pierce Regulatory Affairs Director CRP/EFB/Iac d before me this ;tc.

,2016.

My commission expires: /6, ~

  • J_() I 1 -Table 2.2.A-Vogtle Electric Generating Plant On-Shift Staffing cc:

Nuclear Regulatory Commission Mr. W. M. Dean, Director of the Office of Nuclear Reactor Regulations Ms. C. Haney, Regional Administrator Mr. M. Delligatti, Deputy Division Director, DNRL Mr. L. Burkhart, Br~nch Chief, LB4, DNRL Mr. M. E. Ernstes, Branch Chief, DRP, All Mr. A. E. Martin, NRR Senior Project Manager-Vogtle 1 & 2 Mr. S. A. Williams, NRR Project Manager-Farley Mr. M. D. Orenak, NRR Project Manager-Hatch Mr. C. Patel, NRO Project Manager-Vogtle 3 & 4 Mr. P. Kallan, Senior Project Manager-Vogtle 3 & 4 Mr. B. M. Bavol, Project Manager-Vogtle 3 & 4 Ms. A. Reyes, Project Manager-Vogtle 3 & 4 Ms. M. A. Sutton, Project Manager-Vogtle 3 & 4 Mr. G. Khouri, Senior Project Inspector-Vogtle 3 & 4 Mr. D. H. Hardage, Senior Resident Inspector-Hatch Mr. A. M. Alen, Resident Inspector-Vogtle 1 & 2 Mr. P. K. Niebaum, Senior Resident Inspector-Farley Mr. J. D. Fuller, Senior Resident Inspector, Vogtle 3 & 4 Ms. S. Temple, Resident Inspector-Vogtle 3 & 4 State of Alabama Dr. T. M. Miller, State Health Officer, Department of Public Health State of Georgia Mr. J. H. Turner, Director-Environmental Protection Division

U.S. Nuclear Regulatory Commission NL-16-0739 Page3 Blind Copy List (without enclosures unless noted):

Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bast, Executive Vice President & Chief Nuclear Officer Mr. M.D. Rauckhorst, Construction V.P.- Vogtle 3-4 Mr. D. H. Jones, Vice President Technical Compliance-Voqtle 3-4 Ms. K. D. Fill-Vice President-Operational Readiness Ms. C. A. Gayheart, Vice President - Farley Mr. D. R. Vineyard, Vice President-Hatch Mr. B. K. Taber, Vice President-Vogtie 1-2 Mr. D. R. Madison, Vice President-Aeet Operations Mr. M. D. Meier, Vice President-Regulatory Affairs Mr. B. J. Adams, Vice President-Engineering Mr. C. R. Pierce, Regulatory Affairs Director - Fleet Mr. B. H. WhiUey, Regulatory Affairs Director-Nuclear Development Mr. M. J. Vox, Regulatory Affairs Director-Vogtie 3-4 Ms. B. L. Taylor, Regulatory Affairs Manager-Farley Mr. G. L. Johnson, Regulatory Affairs Manager-Hatch Mr. G. W. Gunn, Regulatory Affairs Manager-Vogtle 1-2 Mr. W. A. Sparkman, Licensing Manager-Nuclear Development Mr. T. W. Yelverton-Commercial Director-Vogtle 3-4 Mr. D. L. Fulton - Nuclear Development Environmental Manager Mr. J. C. Harrelson-Project Manager Mr. T. R. Takats-Engineering Supervisor Mr. J.P. Redd-Licensing Supervisor Mr. J. G. Hall-Emergency Preparedness Supervisor RTYPEs: CFA04.054; CHA02.004; CVC7000; VND.LI.LOO (w/enclosures)

Ale AR.01.02.06 (w/enclosures)

Oglethorpe Power Corporation Mr. M. W. Price Mr. Ms. K. T. Haynes Ms. A Whaley Municioal Electric Authorltv of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros WECTEC Ms. K. Stoner Mr. C. A. Castell Westinghouse Electric Comoany. LLC Mr. R. Easterling Mr. J. W. Crenshaw Mr. C. D. Churchman Mr. L. Woodcock Mr. P. A. Russ Mr. G. F. Couture Mr. M. Y. Shaqqo Other Mr. J. E. Hesler, Bechtel Power Corporation Ms. L.A. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Ms. S. W. Kemizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham Mr. R Grumbir, APOG Ms. A. RiceMr. J. R. Bouknight, South Carolina Electric & Gas Company Mr. D. Kersey, South Carolina Electric & Gas Company Mr. B. Kitchen, Duke Energy Mr. S. Franzone, Florida Power & Light

ATTACHMENT1 Vogtle Electric Generating Plant On-Shift Staffing (Units 3 and 4)

Table 2.2.A

SNC Response to 2nd Set of RAis Standard E-Pian LAR Attach. 1 Table 2.2.A-Vogtle Electric Generating Plant On-Shift Staffing Vogtle 3 & 4 Major Major Tasks Position On-Shift On-Shift Functional Unit3 Unit4 Area Emergency Shift Manager (SM)/

1 1

Direction and Emergency Director Control (ED)

Plant Shift Supervisor (SAO) 1 1

Operations and Assessment of Shift Support 1

Operational Supervisor /Fire Aspects Brigade(SRO/FBL)

Licensed Operator 1

(SAO or RO)

Reactor Operators 2

2 (RO)

System Operators (SO) 2 2

System Operators I Fire 4

Brigade {SO/FBM)

Plant System Technical Support Shift Technical Advisor Note 1 Engineering, Repair and Corrective Actions Notification/

Notify licensee, State Licensed Operator Note 1 Communication local and Federal (SAO or RO) personnel & maintain communication Radiological Offsite Dose Chemistry Technician Accident Assessment Assessment In-plant surveys RP Technician 1

and Support of Operational Offsite Surveys Onsite RP Technician Accident (out-of-plant)

Assessment Protective Radiation Protection:

RP Technician 1

Actions

a. Access Control
b. RP Coverage for repair, corrective actions, search and rescue first-aid &

firefighting

c. Personnel monitoring
d. Dosimetry Chemistry/Radio-Chemistry Technician 1

chemistry Page 1 Shared Resources with Unit 1&2 1 NOte ;j 1

NOte ;j 1

Note ;j 1

1

SNC Response to 2nd Set of RAis Standard E-Pian LAR Attach. 1 Plant System Repair and Corrective Engineering, Actions Repair and Corrective Actions Firefighting Rescue Operations and First Aid Plant Access and Personnel Accountability Maintenance Supervisor Mechanic Electrician I & C Technician Total:

Fire Brigade Note2 Rescue Operations/Fir stAid Note1 Security Note 1 - May be provided by shift personnel assigned other functions 21 5

Sec Plan Note 2 - Fire Brigade made up of Fire Brigade Leader (SSS) and 4 System Operators Note 3 - Vogtle Unit 1 &2 resource may be used for events impacting multiple units Page2 1

1 1

1 9

2