ML16141A914
| ML16141A914 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 05/22/1995 |
| From: | Berkow H NRC (Affiliation Not Assigned) |
| To: | Tuckman M DUKE POWER CO. |
| Shared Package | |
| ML16141A915 | List: |
| References | |
| TAC-M89754, TAC-M89755, TAC-M89756, NUDOCS 9505250214 | |
| Download: ML16141A914 (4) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 22, 1995 Mr. M. S. Tuckman Senior Vice President Nuclear Generation Duke Power Company P.O. Box 1006 Charlotte, NC 28201-1006
SUBJECT:
OCONEE NUCLEAR STATION UNITS 1, 2, AND 3 - RELIANCE ON APPENDIX J TEST RESULTS IN LIEU OF CODE HYDROSTATIC PRESSURE TEST FOR INSERVICE INSPECTION - RELIEF REQUEST NO. 94-GO-002 (TAC NOS. M89754, M89755, AND M89756)
Dear Mr. Tuckman:
The purpose of this letter is to authorize your proposed alternative (Code Case N-522) to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code).
This provides relief for the Inservice Inspection (ISI) program.
In a letter dated June 22, 1994, you proposed alternatives to the requirements of the ASME Code. You requested approval to implement the alternative rules of ASME Section XI Code Case N-522 and Code Case N-498-1, pursuant to 10 CFR 50.55a(a)(3), for 10-year hydrostatic testing on-Class 2 systems. Code Case N-522 allows use of.the leakage testing requirements of 10 CFR Part 50, Appendix J, to satisfy the periodic pressure test requirements of ASME Code,Section XI, Subsection IWC, for those isolated portions of Class 2 piping which are classified only for the purpose of containment integrity. Our evaluation to implement Code Case N-498-1 is being addressed separately.
We have reviewed the information provided in your June 22, 1994, letter in support of the relief request. Based on the information submitted, the alternative for hydrostatic testing contained in your proposal, use of Code Case N-522 for Code Class 2 systems, is authorized pursuant to 10 CFR 50.55a(a)(3)(i) because the proposed alternative provides an acceptable level of quality and safety. The alternative testing -is authorized for the duration of the currently approved ISI program.
NBC FILE CENTER COP 9505250214 950522 PDR ADOCK 05000269 P
-PDR
Mr. M.
May 22, 1995 You stated in the.June 22, 1994, submittal that you intended to implement Code Case N-522 at Oconee Unit 2 in October 1994. Our letter dated 0ctober 11, 1994, informed you that we would be unable to compiet our review of this request in time to support this schedule. As a result, you requested approval to defer the testing covered by this Code Case-to thenext scheduled outage for Oconee Unit 2, in order to allow time to completei-the review.
This outage would be the first outage in the third 10-year inspection interval.,We authorized this deferral in a letter dated January 17, 1995. Authorizafion to implement Code Case N-522 applies to this deferred, testing..
The staff has concluded that the use of Code Case N-522 is authorized pursuant to 10 CFR 50.55a(a)(3)(i). Accordingly, the above identified relief reques is hereby authorized, subject to the conditions detailed in"the enclosed Safety Evaluation.
Sincerely, original signed by Herbert N. Berkow, Director Project:Directorate 11-2 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/encl:
See next page DISTRIBUTION (Docket File PUBLIC PD22 Reading File W. Russell/F. Miraglia R. Zimmerman R. Spessard J. Lieberman E. Jordan G. Hill (6)
OPA OC/LFDCB G. Tracy S. Varga J. Zwolinski OGC ACRS (4)
E. Merschoff, RH R. Crlenjak, RH DOCUMENT NAME: G:\\OCONEE\\0CO89754.522 To receive a copy of this document, Indicate In the box: "C" = Copy without atte ant/enclosure "E"N" No copy OFFICE ILA:PD22:DRPQ\\
E PM:PD22:DRRE E
P I NAME
'LBerry LWiens:dt GBagchi W
H2eriow DATE
/ ()(
/95 14/
/95
/ /95 14/ '/95 L-1 !/95 OFFICIAL RECORD COPY A,'
Mr. M. May 22, 1995 You stated in the June 22, 1994, submittal that you intended to implement Code Case N-522 at Oconee Unit 2 in October 1994. Our letter dated October 11, 1994, informed you that we would.be unable to complete our review of this request in time to support this schedule. As a result, you requested approval to defer the testing covered by this Code Case to the next scheduled outage for Oconee Unit 2, in order to allow time to complete the review. This outage would be the first outage in the third 10-year inspection interval. We authorized this deferral in a letter dated January 17, 1995. Authorization to implement Code Case N-522 applies to this deferred testing.
The staff has concluded that the use of Code Case N-522 is authorized pursuant to 10 CFR 50.55a(a)(3)(i). Accordingly, the above identified relief request is hereby authorized, subject to the conditions detailed in the enclosed Safety Evaluation.
Si r ly, He bert N. Berk w, Director Project Directorate 11-2 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/encl:
See next page
Duke Power Company Oconee Nuclear Station cc:
A. V. Carr, Esquire Mr. Ed Burchfield Duke Power Company Compiance 422 South Church Street Duke Power Company.
Charlotte, North Carolina 28242-0001 Oconee Nuclear Site P. 0. Box 1439 J. Michael McGarry, III, Esquire Seneca, South Carolina 29679 Winston and Strawn 1400 L Street, NW.
Ms. Karen E. Long Washington, DC 20005 Assistant Attorney General North Carolina Department of Mr. Robert B. Borsum Justice Babcock & Wilcox P.O. Box 629 Nuclear Power Division Raleigh, North Carolina 27602 Suite 525 1700 Rockville Pike Mr. G. A. Copp Rockville, Maryland 20852 Licensing -
ECO50 Duke Power Company Manager, LIS 526 South Church Street NUS Corporation Charlotte, North Carolina 28242-0001 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Dayne H. Brown, Director Division of Radiation Protection Senior Resident Inspector North Carolina Department of U. S. Nuclear Regulatory Commission Environment, Health and Route 2, Box 610 Natural Resources Seneca, South Carolina 29678 P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Regional Administrator, Region II U. S. Nuclear Regulatory Commission Mr. J. W. Hampton 101 Marietta Street, NW. Suite 2900 Vice President, Oconee Site Atlanta, Georgia 30323 Duke Power Company P. 0. Box 1439 Max Batavia, Chief Seneca, South Carolina 27679 Bureau of Radiological Health South Carolina Department of Health.
and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 County Supervisor of Oconee County Walhalla, South Carolina 29621