Text
REGULA Y INFORMATION DISTRIBUTI*SYSTEM (RIDS)
ACCESSION-NBR:8009030507 DOC.DATE: 80/08/25 NO RIZED: NO DOCKET #
FACIL:50-287 Oconee Nucear Station, UnIt 3, Duke Power CoV.
05000287 AUTH,NAME:
AUTHOR AFFILIATION PARKERW.O.
Duke Power Co.,
RECIP.NAME RECIPIENT AFFILIATION DENTON,H.R.
Office of Nuclear Reactor Regulation, Director:
REIDRW.
Operating Reactors Branch 4 SUBJECTi Forwards.proposed revision to Tech Specs to support Unit 3 at full rated power,during Cycle 6 & B&W rept "Oconee Unit 3',Cyc le 6 Reload Rept'.
- f7t A
4 S-oofo a
?
/
DISTRIBUTIONCODE: AOlS COPIES RECEIVED:LTR L
SIZE:
TITLE: General Distribution: for after Issuance of Operating Lic, NOTES:M Cunminaham;all amends to FSAR & changes to, Tech Specs..
05000287 W~C
/3s~t /&4 p/o.
co0 RECIPIENT COPIES RECIPIENTi COPIES ID CODE/NAME!
LITTR ENC ID CODE/NAMEi LTTR ENCLI ACTION:
REIDR..
04 13 13 INTERNALI D/DIRHUMIFAC08 1
1 DIRHUM FACt 07 1
1 I&E; 06 2
2 NRCIPR.
02 1
1 to 0
OR ASSESS BR 10 1
- 0.
G FIL 01
- 1. 1 EXTERNAL: ACRS 09 16 16 LPOR 03 1
1 NSIC 05
- 1.
1 SEP 4 1980 TOTAL NUMBER OF COPIES REQUIRED: LTTR 39 ENCLi 37
DUKE POWER COMPANY POWER BUTDIING 422 SOUTH CHURCH STREET, CHARLOTTE, N. C. 28242 WILLIAM 0. PARKER.JR.
August 25, 1980 Vice PRESIDENT TELEPONE;AREA 704 STEAM PROOUCTION 373-4083 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:
Mr. R. W. Reid, Chief Operating Reactors Branch No. 4
Subject:
Oconee Nuclear Station Unit 3 Docket No. 50-287
Dear Sir:
Pursuant to 10CFR 50, §50.90, please find attached proposed changes to the Oconee Nuclear Station (ONS) Technical Specifications which are required to support the operation of Oconee Unit 3 at full rated power during Cycle 6.
This proposal contains changes which concern the following:
- 1. Core Protection Safety Limits of Specification 2.1;
- 2. Protective System Maximum Allowable Setpoints of Specification 2.3;
- 3. Rod Position Limits of Specification 3.5.2; and
- 4. The addition of new Technical Specification 3.1.11 to clarify "Shutdown Margin" as used at ONS.
Also attached is Babcock and Wilcox Report BAW-1634, "Oconee Unit 3, Cycle 6 Reload Report."
This report includes a summary of Cycle 6 operating para meters and contains the safety analyses supporting the operation of Oconee 3, Cycle 6 core at rated power in accordance with the Technical Specifications provided.
Startup testing of Oconee Unit 3, Cycle 6 will be performed in accordance with the report entitled "Oconee Nuclear Station Generic Startup Physics Test Program,"
which was submitted to the Staff by my letter of July 11, 1980.
00/0 5 80 67-0 10 5cOo7e
Mr. Harold R. Denton, Director August 25, 1980 Page Two The design cycle length for cycle 6 is 376 EFPD. Because of this, certain surveillance frequencies need to be revised from performance on an annual basis to performance each refueling outage. The review of the Oconee Tech nical Specifications in this area is in progress and a supplement reflecting the desired changes will be provided at a later date.
This proposed revision to the ONS Technical Specifications is considered to be one Class IV amendment for Unit 3 with two Class I amendments for Units I and
- 2. Therefore, pursuant to 10CFR 170, §170.12, please find enclosed a check in the amount of $13, 100 for all applicable licensing fees.
Very truly yours, s/William 0. Parker, Jr.
William 0. Parker, Jr.
FTP:scs Attachment
Mr. Harold R. Denton, Director August 25, 1980 Page Three WILLIAM 0. PARKER, JR., being duly sworn, states that he is Vice President of Duke Power Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission this request for amendment of the Oconee Nuclear Station Technical Specifications, Appendix A to Facility Operating Licenses DPR-38, DPR-47 and DPR-55; and that all statements and matters set forth therein are true and correct to the best of his knowledge.
s/William 0. Parker, Jr.
William 0. Parker, Jr., Vice President Subscribed and sworn to before me this 25th day of August, 1980.
s/Sue C. Sherrill Notarial Seal Notary Pubilc My Commission Expires: