YANKEE ATOMIC ELECTRIC COMPANY 49 Yankee Road, Rowe, Massachusetts 01367 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555 - 0001 April 20, 2016 BYR 2016-021 10 CFR 50.4 and 10 CFR 50.36a(a)(2)
Yankee Atomic Electric Company Yankee Nuclear Power Station Independent Spent Fuel Storage Installation NRC License No. DPR-3 (NRC Docket No.50-029)
Subject:
Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2015 10 CFR 50.36a(a)(2), Section 2.3.2 of Appendix C of the Yankee Atomic Electric Company (Y AEC) Quality Assurance Program (QAP) for the Yankee Rowe Independent Spent Fuel Storage Installation (ISFSI), and Section F.2 of the Yankee Nuclear Power Station ISFSI Off-Site Dose Calculation Manual (ODCM), require Y AEC to submit an Annual Radioactive Effluent Release Report. Enclosure 1 provides this report for the period of January 1 through December 31, 2015.
Section 2.3.1 of Appendix C of the Y AEC QAP for the Yankee Rowe ISFSI and Section F.1 of the Yankee Nuclear Power Station ISFSI ODCM require the submittal of an Annual Radiological Environmental Operating Report. Enclosure 2 provides the report for the period of January 1 through December 31, 2015.
Section 2.2b) of Appendix C of the Y AEC Quality Assurance Program for the Yankee Rowe ISFSI requires that any changes to the ODCM to be submitted as part of or concurrent with the Annual Radioactive Effluent Release Report. Enclosure 3 provides Revision 23 to the Yankee Nuclear Power Station ISFSI ODCM. It was issued during the period of January 1 through December 31, 2015.
If you have any questions regarding this submittal, please do not hesitate to contact me at (413) 424-5261 ext. 303.
Respectfully,
~c['~
ISFSI Manager
Yankee Atomic Electric Company BYR 2016-021/April 20, 2016/Page 2
Enclosures:
- 1. Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Annual Radioactive Effluent Release Report, January-December 2015.
- 2. Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Annual Radiological Environmental Operating Report, January-December 2015
- 3. Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Off-Site Dose Calculation Manual, Revision 23 cc:
D. Dorman, NRC Region I Administrator R. Powell, Chief, Decommissioning Branch, NRC, Region I J. Goshen, NRC Project Manager J. Giarrusso, Planning, Preparedness & Nuclear Section Chief, MEMA J. Cope-Flanagan, Assistant General Counsel, MDPU J. Reyes, State of Massachusetts Office of the Attorney General
ENCLOSURE 1 YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY -DECEMBER 2015 BYR 2016-021
YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-3 and SFGL-13 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2015 Radiation Safety & Control Ser*ices April 2016 Prepared by:
Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885-2468
EXECUTIVE
SUMMARY
Tables 1 and 2 summarize the quantity of radioactive gaseous and liquid effluents, respectively, for each quarter of 2015. There were no gaseous or liquid releases in 2015. Table 3 summarizes waste shipped off-site for disposal for each half year of 2015. There was no waste shipped for disposal in 2015.
Appendices A and B indicate the status of reportable items per the requirements of the Off-site Dose Calculation Manual (ODCM). There were no reportable items in 2015.
Appendix C presents any changes in the ODCM. The ODCM was revised in 2015.
YNPS 2015 Annual RER Report Page 2of16
Table 1 YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Gaseous Effluents-Summation of All Releases Nuclides Released Units 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter A. Fissi.on and Activation Gases Total Release Ci N/A*
N/A*
N/A*
N/A*
Average release rate
µCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
B. Iodines Total Iodines released Ci N/A*
N/A*
N/A*
N/A*
Average release rate
µCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
C. Particulates Particulates Released Ci N/A*
N/A*
N/A*
N/A*
Average release rate
µCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
NIA*
N/A*
Gross alpha radioactivity Ci N/A*
N/A*
N/A*
N/A*
D. Tritium Total release Ci N/A*
N/A*
N/A*
N/A*
Average release rate
µCi/s N/A*
N/A*
N/A*
N/A*
Percent of regulatory limit N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storag~ Installation (ISFSI)
Error N/A*
N/A*
N/A*
N/A*
YNPS 2015 Annual RER Report Page 3of16
Table 1A YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Gaseous Effluents - Ground Level Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
.... ***::* **.: ; '.. :**; *:.m.:..,... ::;:.:::
- } '
- ,
- r :.;:; ;,
'.::,~::;.;,;.:. *.: *:!:':*,;:'.~'.:::: ::::,: ; ;*.
- 11
- :Jf:is.s1on.G.as.es"~:1,:::;,.. '..',.,
... '*1:~'
- !l*;.....
Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-138 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- 2';:i0dines*' * :~:;;::;,:.*:
- i~., '::;:::*::;:'* ;;'.':*
- ~:
- ... \\ ;,
- ~i :;:; *....
- ,;;; 1
- :.::i::*
- . '*
- ;*..;;::.,~:;: ;* t.:...r+:*.:..'.J:*i lodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- '3*.;Part:i c*u*fates';<:' ** *:*:.::,,::;, *. "'.. ;; /:~;,::::~:~
.*~,.*
,,.~,',;.. ' ~", "~'"';w.~,'"t'.:~:"(;,i,f~i,,;,*"**~.S.i}r".;,&
- ~;
- *. ~~"'}~'. :!l': *.*
'"';:":;:~:::::.. :1r::*1.;:,' E:!+ '.i::J::i:l!*:!;'.21 **:;:
+:>:
- w
... I*.,*!: ::1:t*I.;.. ;\\*:;
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 4of16
Table 18 YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Gaseous Effluents - Ground Level Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- t: Fi:ssioh Gases.*
- l Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-138 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- 2. Iodines lodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- 3. Particulates Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*.
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 5of16
Table 1C YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Gaseous Effluents - Elevated Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
- 1. 'FHision Gases' H
'i,:,,
3 Krypton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-85m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. Iodines lodine-131 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci.
NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 6of16
Table 10 YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Gaseous Effluents - Elevated Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter
'1. f:issfon.Gases. _:
Krypton-85 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-85m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krvpton-87 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Krypton-88 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 2. Iodines lodine-131 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
NIA*
- 3. Particulates Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable There are no gaseous effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 7of16
Table 2 YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Liquid Effluents - Summation of All Releases Nuclides Released Unit 1st 2nd 3rd Quarter Quarter Quarter A. Fission and Activation Products Total Release (not including Ci N/A*
N/A*
N/A*
tritium, gases, alpha)
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
B. Tritium Total Release Ci N/A*
N/A*
'NIA*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
C. Dissolved and Entrained Gases Total Release Ci N/A*
N/A*
N/A*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
D. Gross Alpha Radioactivity Total release Ci N/A*
N/A*
N/A*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
durinQ period E. Volume of Waste Released Liters N/A*
N/A*
N/A*
(prior to dilution)
F. Volume of Dilution Water Liters N/A*
N/A*
N/A*
Used During Period N/A*= Not Applicable 4th
. Quarter N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
There are no liquid effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
Error N/A*
N/A*
N/A*
N/A*
YNPS 2015 Annual RER Report Page 8of16
Table 2A YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Liquid Effluents-Batch Mode
. Nu elides *Released.. Un if "*".1st
- . 2nd 3rd'*
'0 ""
Qua:rt~r *** '* Qt1arter J,
Quarter Strontium-89 Ci N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
lodine-131 Ci N/A*
N/A*
N/A*
Cobalt-58 Ci N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
lron-59 Ci N/A*
N/A*
N/A*
Zinc-65 Ci N/A*
N/A*
N/A*
Manganese-54 Ci N/A*
N/A*
N/A*
Chromium-51 Ci N/A*
N/A*
N/A*
Zirconium-Niobium-95 Ci N/A*
N/A*
N/A*
Molybdenum-99 Ci N/A*
NIA*
N/A*
Technetium-99m Ci N/A*
N/A*
N/A*
Barium-Lathanium-140 Ci N/A*
N/A*
N/A*
Cerium-141 Ci N/A*
N/A*
N/A*
Others-lron-55 Ci N/A*
N/A*
N/A*
Antimony-125 Ci N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
Total for period (above)
Ci N/A*
N/A*
N/A*
Dissolved and Entrained Ci N/A*
N/A*
N/A*
Gasses Tritium Ci N/A*
N/A*
N/A*
Gross Alpha Ci N/A*
N/A*
N/A*
N/A*= Not Applicable
- ._.~th
- Total~*
- Quarter **
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
There are no liquid effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 9of16
Table 28 YNPS ISFSI Effluent and Waste Disposal Annual Report 2015 Liquid Effluents - Continuous Mode Nuclides Released Unit 1st 2nd 3rd Quarter Quarter
.Quarter Strontium-89 Ci NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
. Ci NIA*
NIA*
NIA*
lodine-131 Ci NIA*
NIA*
NIA*
Cobalt-58 Ci NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
lron-59 Ci NIA*
NIA*
NIA*
Zinc-65 Ci NIA*
NIA*
NIA*
ManQanese-54 Ci NIA*
NIA*
NIA*
Chromium-51 Ci NIA*
NIA*
NIA*
Zirconium-Niobium-95 Ci NIA*
NIA*
NIA*
Molybdenum-99 Ci NIA*
NIA*
NIA*
Technetium-99m Ci NIA*
NIA*
NIA*
Barium-Lathanium-140 Ci NIA*
NIA*
NIA*
Cerium-141 Ci NIA*
NIA*
NIA*
Others-lron-55 Ci NIA*
NIA*
NIA*
Antimony-125 Ci NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
Total for period (above)
- Ci NIA*
NIA*
NIA*
Dissolved and Entrained Ci NIA*
NIA*
NIA*
Gasses Tritium Ci NIA*
NIA*
NIA*
Gross Alpha Ci NIA*
NIA*
NIA*
NIA*= Not Applicable 4th Totals Quarter NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
There are no liquid effluents associated with the Yankee Nuclear Power Station Independent Spent Fuel Storage Installation (ISFSI)
YNPS 2015 Annual RER Report Page 10of16
Table 3 YNPS ISFSI Effluent and Waste Disposal Annual Report First Half 2015 Low Level Waste Shipments Resins, Filters and Evaporator Volume Bottoms Waste Class Solidifying A~ent f t;1 m;1 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Dry Active Waste Volume Waste Class Solidifying Agent f t3 m;1 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Irradiated Components Volume Waste Class Solidifying Agent f t3 m;1 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Other Waste Volume Waste Class Solidifying Agent f t3 mJ A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
YNPS 2015 Annual RER Report Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Page 11of16
Table 3A YNPS ISFSI Effluent and Waste Disposal Annual Report Second Half 2015 Low Level Waste Shipments Resins, Filters and Evaporator Volume Bottoms Waste Class Solidifying Agent ft3 m3 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Dry Active Waste Volume Waste Class Solidifying Agent ft3 m3 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Irradiated Components Volume Waste Class Solidifying Agent ft3 m3 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
Other Waste Volume Waste Class Solidifying Agent ft3 m3 A
0 0
B 0
0 c
0 0
All 0
0 Major radionuclides for above data:
YNPS 2015 Annual RER Report Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Page 12of16
Appendix A Radiation Dose Assessment There were no gaseous or liquid effluent releases in 2015. Therefore, an assessment of radiation doses to the most likely exposed member(s) of the public to show compliance with 40CFR190or10CFR72.104 from effluents was not required.
YNPS 2015 Annual RER Report Page 13of16
Appendix B Unplanned Releases There were no unplanned releases of radioactive materials in effluents in 2015.
YNPS 2015 Annual RER Report Page 14of16
AppendixC Off-site Dose Calculation Manual Changes There were changes to the Off-site Dose Calculation Manual in 2015. The following table presents the changes to the ODCM.
Section Proposed Change Rationale 1.0, 2.3.1, As applicable, expanded references to 10 The expanded references accurately reflect 3.2 CFR 72.104 to 10 CFR 72.104(a).
the correct subpart of the code.
1.0,2.3.1, As applicable, expanded references to 40 The expanded references accurately reflect 3.2 CFR 190 to 40 CFR 190.10(a) or40 CFR the correct subpart of the code.
190.11.
1.0, 2.3.1, Administrative, editorial, or grammatical Corrects the language and grammar utilized 3.2 changes.
in the document.
1.0, Figure Replaced the term Owner Controlled Area Controlled Area is defined in 10 CFR 72.3 1.2 with Controlled Area and referenced in 10 CFR 72.104 and 10 CFR 72.106. The term is also used in 10 CFR 20 Subpart D.
1.0 Defined that the Site Boundary is the The NRC's Safety Evaluation Report current 1 O CFR 50 Licensed Area regarding the release of land identified that the site boundary had changed. The applicable reference is: Letter from K. I.
McConnell (NRC) to W. Norton (YAEC),
Yankee Nuclear Power Station - Release of Land from Part 50 License, dated August 10, 2007.
1.1 Defined the property boundary and the Previously, the Site Boundary was also the controlled area, and modified the property boundary. However, the NRC definition of the site boundary.
Safety Evaluation Report dated August 10, 2007, identified that the site boundary needs to be modified to reflect the area governed by the YNPS 10 CFR 50 License.
A definition for the property boundary was provided for information.
The controlled area boundary is utilized for establishing that the dose to members of the public complies with 10 CFR 20, Subpart D, 10 CFR 72.104(a) and 40 CFR 190.10(a).
2.3.2 The Controlled Area boundary is the This is consistent with 10 CFR72.106.
location that the site utilizes for establishing that the dose to members of the public complies with 1 O CFR 72.104(a) and 40 CFR 190.10(a).
2.3 Identifies that realistic occupancy factors Provides a more thorough description of the are applied to the net exposure values to methodology to determine the annual dose.
determine the annual dose.
YNPS 2015 Annual RER Report Page 15of16
Section Proposed Change Rationale 3.1 Currently, the section requires missing The change clarifies that missing data will be data to be submitted in a supplementary submitted it if is available. The current report. This was revised to identify that if wording would be a compliance trap if the the data is available, it will be submitted in data was not available.
the next annual report.
4.0 Added references to the Quality References added to be consistent with Assurance Program, NRC Safety changes described above and to provide Evaluation dated August 10, 2007, 10 applicable source documents.
CFR 72.104, 40 CFR 190.10, and 40 CFR 190.11.
YNPS 2015 Annual RER Report Page 16of16
BYR 2016-021 ENCLOSURE2 YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT JANUARY -DECEMBER 2015
YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-3 and SFGL-13 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT January - December 2015
~RSCS Radiation Safety & Control Services April 2016 Prepared by:
Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885-2468
EXECUTIVE
SUMMARY
Yankee Nuclear Power Station was permanently shutdown in 1991. All fuel has been transferred into dry storage casks and placed at the Independent Spent Fuel Storage Installation. The Radiological Environmental Monitoring Program (REMP) for the Yankee Nuclear Power Station (YNPS) Independent Spent Fuel Storage Installation (ISFSI) located in Rowe, MA was continued for the period January through December 2015 in compliance with the YNPS Offsite Dose Calculation Manual (ODCM).
By design, there are no liquid or gaseous effluents associated with the operation of the ISFSI. Therefore, the ODCM only requires monitoring of direct exposure from the facility. TLDs were used to measure direct gamma exposure at six locations in the vicinity of the ISFSI and one control location 7.6 kilometers away. The results of these measurements showed no significant change in exposure rates and potential doses to members of the public during the monitoring period. The results of the monitoring performed in 2015 also show that operating the YNPS ISFSI results in only a sm~ll fraction of the 40 CFR Part 190 and 10 CFR Part 72.104 direct radiation dose limit of 25 mrem/year to members of the public.
YNPS 2015 Annual REO Report Page 2of27.
TABLE OF CONTENTS Section
1.0 INTRODUCTION
........................................................................................... 6 2.0 GENERAL ISFSI AND SITE INFORMATION................................................ 7 3.0 PROGRAM DESIGN..................................................................................... 7 3.1 MONITORING ZONES............................................................................................. 8 3.2 PATHWAYS MONITORED........................................................................................ 8
3.3 DESCRIPTION
OF MONITORING PROGRAM............................................................. 8 4.0 RADIOLOGICAL DATA
SUMMARY
TABLES............................................ 15 5.0 ANALYSIS OF ENVIRONMENTAL RESULTS........................................... 26 5.1 SAMPLING PROGRAM DEVIATIONS....................................................................... 26 5.2 DIRECT RADIATION PATHWAY............................................................................. 26
6.0 REFERENCES
............................................................................................ 27 YNPS 2015 Annual REO Report Page 3 of 27
LIST OF TABLES 3.1 Radiological Environmental Monitoring Program.................................... 9 3.2 Radiological Environmental Monitoring Locations................................ 10 4.1 TLD Measurements by Half-Year.............................................................. 16 4.2 TLD Data Summary.................................................................................... 17 4.3 Direct Dose from ISFSI Operations.......................................................... 18 YNPS 2015 Annual REO Report Page 4 of 27
LIST OF FIGURES Figure 3.1 All Radiation Monitoring Locations.......................................................... 11 3.2 Onsite Direct Radiation Monitoring Locations........................................ 12 3.3 Direct Radiation Monitoring Locations (Within 1 mile).......................... 13 3.4 Offsite Control Location............................................................................ 14 4.1 Annual Dose Trend at GM-02.................................................................... 20 4.2 Annual Dose Trend at GM-06.................................................................... 21 4.3 Annual Dose Trend at GM-15.................................................................... 22 4.4 Annual Dose Trend at GM-16.................................................................... 23 4.5 Annual Dose Trend at GM-17.................................................................... 24 4.6 Annual Dose Trend at GM-21.................................................................... 25 YNPS 2015 Annual REO Report Page 5 of 27
1.0 INTRODUCTION
This report summarizes the findings of the Radiological Environmental Monitoring Program (REMP) conducted by Yankee in the vicinity of the Independent Spent Fuel Storage Installation in Rowe, Massachusetts during the calendar year. It is submitted annually in compliance with the Offsite Dose Calculation Manual (ODCM). The remainder of this report is organized as follows:
Section 2:
Provides a brief description of the Yankee site and its environs.
Section 3:
Provides a description of the overall REMP design. Included is a summary of the ODCM requirements for REMP sampling, tables listing TLD monitoring locations with compass sectors and distances from the ISFSI, and maps showing the location of each of the TLD monitoring locations.
Section 4:
Provides a complete set of TLD data showing measured results (mR) and calculated doses (mrem per year). This section also provides the summarized TLD data in the format specified by the NRG Branch Technical Position on Environmental Monitoring (Reference 1 ).
Section 5:
Provides the results of the calendar year monitoring program. The performance of the program in meeting ODCM requirements is discussed, and the data acquired during the year is analyzed.
Section 6:
References YNPS 2015 Annual REO Report Page 6of27
2.0 GENERAL ISFSI AND SITE INFORMATION The Yankee Nuclear Power Station site is located on over 1800 acres in a predominantly rural area of northwestern Massachusetts, three-quarters of a mile south of the Vermont border. The site resides in the town of Rowe, Massachusetts, approximately 9 air miles east-northeast of North Adams, Massachusetts. The surrounding area is heavily forested and lightly populated.
Hills bounding the river valley rise 500 to 1000 feet above the site, reaching elevations of 21 00 feet.
The Deerfield River is used extensively for hydroelectric power generation both upstream and downstream of YNPS. The Sherman Dam, immediately adjacent to the site, operates as a hydroelectric generating station. Sherman Pond, the impoundment behind this dam, had been used as a source of cooling water for the former power plant.
The former nuclear power plant was voluntarily shut down on October 1, 1991 after 31 years of operation. The site was involved in the process of decommissioning over the years which involved the disassembly and removal of the plant components and structures and was completed in 2006. This process took place in strict conformance with USN RC regulations. Oversight of the site closure process also took place from the U.S. Environmental Protection Agency, the Massachusetts Department of Environmental Protection, and Massachusetts Department of Public Health.
3.0 PROGRAM DESIGN The Radiological Environmental Monitoring Program (REMP) for the Yankee Nuclear Power Station ISFSI was designed to provide assurance to regulatory agencies and the public that the station's environmental impact is known and within anticipated limits. The direct dose limit for members of the public from operation of the ISFSI is 25 mrem per year (References 3 and 4).
The detailed sampling requirements of the REMP are given in the ODCM. The sampling requirements specified in the ODCM are summarized in Table 3.1 of this report. Details of the monitored locations are shown in Table 3.2, as well as Figures 3.1 through 3.4 of this report.
YNPS 2015 Annual REO Report
- Page 7 of 27
3.1 Monitoring Zones The REMP is designed to allow comparison of levels of radioactivity in samples from the area possibly influenced by the ISFSI to levels found in areas not influenced by the ISFSI. The first area is called "indicator stations". The second area is called "control stations". The distinction between the two is based on relative direction from the facility and distance. Analysis of survey data from the two zones aids in determining if there is a significant difference between the two areas. It can also help in differentiating between radioactivity or radiation due to releases and that due to other fluctuations in the environment, such as seasonal variations in the natural background.
3.. 2 Pathways Monitored Based on the design of the ISFSI, only the direct radiation exposure pathway is monitored by the REMP. This pathway is monitored by the collection of thermoluminescent dosimeters (TLDs) which are described in more detail below.
3.3 Description of Monitoring Program 3.3.1 Direct Radiation Direct gamma radiation exposure was continuously monitored during 2015 with the use of thermoluminescent dosimeters (TLDs). At each monitoring location, these TLDs are sealed in plastic bags and attached to an object such as a tree, fence or utility pole. The TLDs are posted and retrieved on a semi-annual basis.
All TLDs are provided and processed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified vendor. The TLDs are placed at various locations around the Independent Spent Fuel Storage Installation (ISFSI). Table 3.2 lists the Station ID Codes, distances and direction of the TLDs from the ISFSI.
3.3.2 Special Monitoring Special samples can be taken that are not required in the ODCM. The sample locations do not appear in Table 3.1 or 3.2 of this report. For this monitoring period, no special samples were collected as part of the YNPS ISFSI Radiological Environmental Monitoring Program.
YNPS 2015 Annual REO Report Page 8of27
Table 3.1 Radiological Environmental Monitoring Program Exposure Collection Analysis Pathway Number of Routine and/or Collection Analysis Analysis Sample Sample Sampling Frequency Type Frequency Media Locations Mode Direct Total Locations: 7 Continuous Semi-Gamma Semi-Radiation (6 around annual dose annual (TLD) perimeter of the site and 1 offsite control location)
YNPS 2015 Annual REO Report Page 9 of 27
Table 3.2 Radiological Environmental Monitoring Locations Distance Direction Station Code Station Description From ISFSI Zone From ISFSI (km)
GM-15 Onsite Perimeter (I)**
1 0.24 NW GM-16 Onsite Perimeter (I)**
1 0.22 NNW GM-17 Onsite Perimeter (I)**
1 o.13 NNE GM-21 Onsite Perimeter (I)**
1 0.17 WSW GM-02 Observation Stand (O)**
1 0.50 NW GM-06 Tunnel Road Readsboro 1
1.30 N
Town Line (0)**
GM-27 Number Nine Road (0)*
2 7.60 ENE
- 2 =Control TLD;
- 1 =Indicator TLD
Figure 3.1 All Radiation Monitoring Locations YNPS 2015 Annual REO Report Page 11 of 27
\\
\\
Figure 3.2 Onsite Direct Radiation Monitoring Locations
\\
\\
\\
\\
I I
I I
I I
I I
I I
I I
I I
I /
I I
\\
\\
GM-2 I
\\
\\
\\
\\
\\
\\
\\
\\
N I I I
I I
I I
I I
I w
\\
I
/
E
\\
j I
I I
/
I OGl'lll-15 O GM-1,6 I
I
/
\\
\\
I
/
\\
\\
I OGM-17
,,."I I
I
/
I I
~/'
I I
I I
I I
I
/
//
I I
,,/
I J
/
I I
I I
I I
I J
I I
I I
I L*g,end I
I I
I I
I s
\\
I
\\
\\
\\ I I
I
\\
ZoneJOwner Controlled Ar ea Yankee ISFSI REMP LD Locations YNPS 2015 Annual REO Report Page 12 of 27
Figure 3.3 Direct Radiation Monitoring Locations (Within 1 mile)
OGM-6 YNPS 2015 Annual REO Report INSET 1 600
~~~!iiiiiiiiiiiiiiiiiiiiiiiiiil Feet 0
300 Page 13 of 27
YNPS 2015 Annual REO Report Figure 3.4 Offsite Control Location 0 GM-27 "C
a::
Ill C'l 0
"C Ill
(/)
INSET 2 0
600
~~~~iiiiiiiiiiiiiiiiiiiiiiiiiiil Feet 300 Page 14 of 27
4.0 RADIOLOGICAL DATA
SUMMARY
TABLES This section summarizes the analytical results of the environmental samples, which were collected during the monitoring period.
Data from direct radiation measurements made by TLDs are presented in Table 4.1.
The s1:1mmarized TLD measurements, shown in Table 4.2, are presented in a format similar to that prescribed in the NRC's Radiological Assessment Branch Technical Position on Environmental Monitoring (Reference 1 ).
Table 4.3 presents the estimated direct dose from ISFSI operations as determined by TLD data shown in Table 4.1.
YNPS 2015 Annual REO Report Page 15 of 27
Station ID GM-02 GM-06 GM-15 GM-16 GM-17 GM-21 GM-27 GM-27a Table 4.1 TLD Measurements by Half-Year (mR)
Location 1st Half-Year 2"d Half-Year Observation Stand 37 42 Tunnel Road Readsboro 45.5 53 Town Line On-site perimeter 52 56 On-site perimeter 48 54 On-site perimeter 42 51 On-site perimeter 44 49 Control 41 45 Control Backup 40 41 Note: The TLD at location GM-06 was not present for retrieval at the end of the first half of 2015. The value listed is the average of the year 2014 measurements.
YNPS 2015 Annual REO Report Page 16 of 27
Table 4.2 TLD Data Summary (mR)
Indicator TLDs Control TLDs Indicator Station With Highest Mean Mean Mean Mean (Range)
(Range)
Station#
(Range)
(No. Measurements)*
(No. Measurements)*
(No. Measurements)*
47.8 41.8 GM-15 54 (37 - 56)
(40 - 45)
(52 - 56)
(11)
(4)
(2)
Note: The TLD at location GM-06 was not present for retrieval at the end of the first half of 2015. The values listed in the Indicator TLDs column include the 2014 average GM-6 value substituted for the missing measurement.
- Each "measurement" is based on semi-annual readings.
YNPS 2015 Annual REO Report Page 17 of 27
Station ID GM-02 GM-06 GM-15 GM-16 GM-17 GM-21 Table 4.3 Direct Dose from ISFSI Operations (mrem) 1st Half-Year 2"d Half-Year NetTLD Calculated Net TLD Calculated Result Dose Result Dose 0.00 0.00 0.00 0.00 5.00 0.29 10.00 0.57 11.50 0.66 13.00 0.74 7.50 0.43 11.00 0.63 1.50 0.09 8.00 0.46 3.50 0.20 6.00 0.34 Max Dose=>
Annual Dose 0.00 0.86 1.40 1.06 0.55 0.54 1.40 Note: The TLD at location GM-06 was not present for retrieval at the end of first half of 2015. The value shown in the Net TLD result column in the 1 51 Half-Year was based upon the average of the year 2014 measurements.
Note: Doses based on a 250 hour0.00289 days <br />0.0694 hours <br />4.133598e-4 weeks <br />9.5125e-5 months <br /> occupancy in both of the first and second half-years.
YNPS 2015 Annual REO Report Page 18 of 27
Radiological Environmental Monitoring Program Trending A series of graphs of REMP TLD data have been developed and are provided for trending purposes. The trending is developed for each of the indicator locations based on the annual historical doses. The trending is provided for the "real members of the public" based on the guidance provided in the ODCM. The analysis of the trends and associated data shows very small annual doses with minor fluctuations in the data. In this report, the uncorrected TLD results have been summarized and the annual doses, calculated for "real members of the public" based upon guidance in the ODCM, have been plotted for trending.
YNPS 2015 Annual REO Report Page 19 of 27
Figure 4.1 Annual Dose Trend at GM-02 GM-02 30.00...,..--------------------
25.00 +---------------------
... 20.00 -+---------------------
~ 15.00 -+---------------------
E 10.00
-t-GM-02 limit 5.00 0.44 0.63 0.17 0.00 0.43 0.11 0.37 0.43 0.00 0.00 T
I 2007 2008 2009 2010 2011 2012 2013 2014 2015 Year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 GM-02 0.44 0.63 0.1 7 0.00 0.43 0.11 0.37 0.43 0.00 YNPS 2015 Annual REO Report Page 20 of 27
Figure 4.2 Annual Dose Trend at GM-06 GM-06 30.00 ~--------------------
25.00 -+-~-------------------
... 20.00 -+----------------------
~ 15.00 -+----------------------
-+-GM-06 E 10.00 +-------------------
-~1-im_i_
t 5
- 00 +-ru". '3..,-----
L
-..,.-0."""""'6-:c 0-. 2 "o-=<. 7.-1 --,o"'.1:1....,,-
1:1 ---,.,u"'
.. '3...,.,-
o-=-.-=-54-:---"o". 7..
4-
..,., u.........
1:1..--
0 2007 2008 2009 2010 2011 2012 2013 2014 2015 Year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010 2011 2012 2013 2014 GM-06 0.92 0.63 0.29 0.71 0.88 0.97 0.54 0.74 2015 0.86 YNPS 2015 Annual REO Report Page 21 of 27
Figure 4.3 Annual Dose Trend at GM-15 GM-15 30.00 ~--------------------
25.00 +-~-------------------
'- 20.00 -+-------------------------
~ 15.00 +---------------------
~
E 10.00 +---------------------
-+-GM-15 limit l.14 1.51 1.77 t:4t)-
I 2010 2011 2012 2013 2014 2015 Year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010
- 2011 2012 2013 2014 2015 GM-15 1.79 1.31 1.88 1.34 1.74 1.14 1.51 1.77 1.40 YNPS 2015 Annual REO Report Page 22 of 27
Figure 4.4 Annual Dose Trend at GM-16 GM-16 30.00 ~--------------------
25.00 +-~-------------------
... 20.00 -!----------------------
~ 15.00 +---------------------
-+-GM-16 E 10.00 +---------------------
limit 2007 2008 2009 2010 2011 2012 2013 2014 2015 Year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 GM-16 1.13 1.20 0.29 0.71 1.68 1.37 0.88 1.06 1.06 YNPS 2015 Annual REO Report Page 23 of 27
Figure 4.5 Annual Dose Trend at GM-17 GM-17 30.00 ~--------------------
25.00 +-~-------------------
... 20.00 +----------------------
~ 15.00 -+---------------------
E 10.00 +-----------------------.,,,.---..,-
~ GM-17 limit 0.86 1.34 1.57 1.08 1.34 0.57 0.55 T
2007 2008 2009 2010 2011 2012 2013 2014 2015 Year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010 2011 2012 2013 2014 2015 GM-17 1.14 1.54 0.86 1.34 1.57 1.08 1.34 0.57 0.55 YNPS 2015 Annual REO Report Page 24 of 27
Figure 4.6 Annual Dose Trend at GM-21 GM-21 30.00 ~--------------------
25.00 +-~-------------------
... 20.00 -+---------------------
~ 15.00 +---------------------
--+-GM-21 E 10.00 +---------------------
limit 5.OO +--i.1.-..t.tti.u.-=o.-=;-7-.-4 -,u""
. ~..,...1,-..,..u'"'.
~-,,----
4
-1"'.u u ~u""
. ~rr
, 1-1-11
--o-~
o.=5 7~. 5 2007 2008 2009 2010 2011 2012 2013 2014 2015 year Annual Doses (mrem/yr)
Location 2007 2008 2009 2010 2011 20f2 2013 2014 2015 GM-21 1.20 0.74 0.97 0.94 1.00 0.91 1.40 0.57 0.54 YNPS 2015 Annual REO Report Page 25 of 27
5.0 ANALYSIS OF ENVIRONMENTAL RESULTS 5.1 Sampling Program Deviations A sampling program deviation is defined as samples that are unobtainable due to hazardous conditions or to malfunction of sampling equipment. Such deviations do not compromise the program's effectiveness and in fact are considered insignificant with respect to what is normally anticipated for this Radiological Environmental Monitoring Program.
There was one deviation in the sampling program in 2015.
The TLD at location GM-06 was not present for retrieval at the end of the first half of the year. A condition report was written to document the finding. The average of the year 2014 GM-06 readings was used as the value for the first half of 2015.
5.2 Direct Radiation Pathway 5.2.1 Annual Dose Trends Direct radiation is continuously measured at 6 indicator locations surrounding the YNPS ISFSI, along with 1 control location at Number Nine Road using thermoluminescent dosimeters (TLDs). These dosimeters are collected semi-annually for readout at the NVLAP certified dosimetry services vendor.
The review of Figures 4.1 through 4.6 shows no significant difference in annual doses over time at the indicator locations ahd their relation to the 25 mrem/yr limit.
5.2.2 Direct Doses from ISFSI Operations The ODCM specifies that a cumulative dose estimate from direct radiation is required to be determined semi-annually. This dose estimate is the potential dose to any real member of the public that could use portions of the site or be present adjacent to the site for recreational activities throughout the year. The ODCM states that direct exposure above background can be estimated by subtracting the average TLD value of the control station from the indicator location measurements. As in previous years, the 2015 dose estimate assumes a total of 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> occupancy for the dose calculation; of which 250 hours0.00289 days <br />0.0694 hours <br />4.133598e-4 weeks <br />9.5125e-5 months <br /> are YNPS 2015 Annual REO Report Page 26of27
used in both the first and second half-years. The most likely location for exposure to a member of the public from the ISFSI is in Sherman Reservoir for boating and fishing; however, the time estimates are conservatively applied to all monitoring locations.
Table 4.3 presents the results of the dose calculations. The highest calculated dose is at Station ID number GM-15. The maximum calculated annual dose at this location is 1.40 mrem. This value is only 6 percent of the 25 mrem per year limit. This represents a conservative dose estimate because a member of the public would normally be situated further away in the reservoir.
6.0 REFERENCES
- 1.
USNRC Radiological Assessment Branch Technical Position, "An Acceptable Radiological Environmental Monitoring Program," Revision 1, November 1979.
- 2.
Yankee Nuclear Power Station Offsite Dose Calculation Manual, Revision
- 23.
- 3.
40 CFR Part 190, "Environmental Radiation Protection Standards for Nuclear Power Operation".
- 4.
10 CFR Part 72.104, "Criteria for Radioactive Materials in Effluents and Direct Radiation from an ISFSI or MRS".
YNPS 2015 Annual REO Report Page 27of27
ENCLOSURE3 YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION OFF-SITE DOSE CALCULATION MANUAL REVISION23 BYR 2016-021
YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
OFF-SITE DOSE CALCULATION MANUAL TABLE OF CONTENTS
1.0 INTRODUCTION
..................................................................................................... 3 1.1 Definitions 2.0
. RADIOLOGICAL ENVIRONMENTAL MONITORING...................................................... 7 2.1 Monitoring Program 2.2 Environmental Monitoring Locations 2.3 Dose/Dose Rate Controls and Calculations 3.0 REPORTING REQUIREMENTS................................................................................... 1 O 3.1 Annual Radiological Environmental Operating Report 3.2 Annual Radi.oactive Effluent Release Report
4.0 REFERENCES
............................................................................................ :................. 11 Revision 23 1
1.1 1.2 LIST OF FIGURES lSFSI Radiological Environmental Monitoring Program TLD Locations (Direct Radiation Pathway)
ISFSl Radiological Environmental Monitoring Program TLD Locations (Direct Radiation Pathway)
Revision 23 2
5 6
1.0 INTRODUCTION
The purpose of this document is to provide a method for demonstrating compliance with the dose limits for MEMBERS OF THE PUBLIC and contains the guidance for submittal of the annual reports required by 10 CFR 50. In addition, the document provides the locations and type of monitoring required for the Radiological Environmental Monitoring Program (REMP).
In accordance with the requirements of 40 CFR 190.1 O(a) and 1 OCFR 72.104(a), the dose to a MEMBER OF THE PUBLIC for radioactive material in effluents and direct radiation from an Independent Spent Fuel Storage Installation (ISFSI) is limited to 25 mrem/yr to the whole body, 75 mrem/yr to the thyroid and 25 mrem/yr to any other critical organ as a result of exposure to planned discharges of radioactive materials to the environment, direct radiation from the !SFSI and any other radiation from uranium fuel cycle operations within the region.
Under normal operations, experience has shown that the !SFSI will be operated at a small fraction of the above dose limits. This is primarily due to the design of the Independent Spent Fuel Storage Installation, which prevents the release of radioactive materials in liquid and particulate form and there are no other uranium fuel cycle operations within 5 miles of the YAEC site. Therefore, the dose equations from Regulatory Guide 1.109, Calculation of Annual Doses to Man From.Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 1 O CFR 50, Appendix I are not necessary for inclusion in the ODCM. The remaining dose component to be considered is from direct radiation. 40 CFR 190(a) and 1 O CFR 72.104(a) establish this dose limit as 25 mrem/yr for MEMBERS OF THE PUBLIC.
Figure 1.2 shows the Controlled Area (CA), and the Site Boundary (i.e., the current 1 O CFR 50 Licensed area).
1.1 DEFINITIONS Member(s) of the Public MEMBER(S) OF THE PUBLIC (for the purposes of 10 CFR 50, Appendix I) shall include all persons who are not occupationally associated with the site. This category does not include employees of the utility, its contractors, or vendors. Also excluded from this category, are persons who enter the site to service equipment or to make deliveries. This category does include persons who use portions of the site for recreational, *occupational, or other purposes not associated with the ISFSI operations.
Offsite Dose Calculation Manual (ODCM)
The ODCM contains the methodology and parameters used in the calculation of off-site doses in the conduct of the Radiological Environmental Monitoring Program. The ODCM also contains (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by the Yankee Quality Assurance Program (QAP) and (2)
Revision 23 3
descriptions of the information that should be included in the Annual Radiological Environmental Operation and Annual Radioactive Effluent Release Reports.
Property Boundary, Site Boundary and Controlled Area The Property Boundary is that line beyond which land is not owned, leased or otherwise controlled by Yankee Atomic Electric Company (YAEC).
The Site Boundary is defined as the boundary for the area governed by Y AEC 10 CFR 50 License in accordance with the NRC Safety Evaluation Report dated August 10, 2007.
The Controlled Area is an area at least 300 meters from the Protected Area Boundary, access to which can be limited by the licensee.
The Controlled Area will be utilized as the boundary for the establishing dose to MEMBERS OF THE PUBLIC. 10 CFR 72.104(a) establishes the annual dose limits that must be met at the Controlled Area boundary during normal operations and anticipated occurrences. Realistic occupancy factors shall be applied at these locations for the purposes of dose calculations.
40 CFR 190.1 O(a) establishes doses that must be met for normal operations.
The Site Boundary and Controlled Area are depicted on Figure 1.2.
Revision 23 4
Prepared/Dale: BRP 06/28113
-~
j Checked/Dale: MGV 0012s113 atnee"9'
~~
Revision 23 5
N
.l * "=
200
- =:z:FM Revision 23 Service lllyot Crodb: Source; Eori, °'9ita1Gk>be,
~oF.ye, E*rthstar Geogtaphies, CNES/Ai'bus OS.
USDA, USGS, AEX, Getmilpping. A*rogrid, ION.
/GP, w-Jsstopo, and the GIS l.JRr Convnuntty J:S.'SI ~~sodAtoa 6
Yankee Rowe Figure 1.2
2.0 RADIOLOGICAL ENVIRONMENTAL MONITORING The Radiological Environmental Monitoring Program (REMP) for the ISFSI monitors for direct radiation exposure only.
There are no radioactive gaseous or liquid effluent pathways associated with the ISFSI.
2.1 Monitoring Program The type and number of radiological environmental monitoring locations including collection and analysis frequencies are shown below.
Number of Exposure Pathway Locations Collection Frequency Type and Frequency of Analysis DIRECT RADIATION 7
Semi"annual Gamma dose, at least once per six months 2.2 Environmental Monitoring Locations The radiological environmental monitoring locations are listed below. These locations are shown on the maps, included as Figures 1.1 and 1.2.
Monitoring Location and.
Oistance From Direction From Exposure Pathway Designated Code the ISFSI (km)
ISFSI DIRECT RADIATION GM"15 On"Site Perimeter 0.24 NW GM"16 On"Site Perimeter 0.22 NNW GM"17 On"Site Perimeter 0.13.
NNE GM"21 On"Site Perimeter 0.17 WSW GM"2 Observation Stand 0.50 NW GM"6 Tunnel Road Readsboro 1.30 N
Town Line (Readsboro Road Barrier)
GM"27*
Number Nine Road 7.60 ENE
- Designated control location. Two TLDs at this sample location.
Revision 23 7
2.3 Dose/Dose Rate Controls and Calculations By design, there are no liquid or gaseous effluents associated with the operation of the ISFSI. With the completion of site remediation activities, along with the removal of all systems or operations that generated, contained or processed waste gas or airborne particulates, there are no longer any gaseous or liquic::I effluent releases from site operations. Therefore, requirements for control, sampling, analyzing, monitoring or dose impact assessment for radioactive liquids or gases are not needed.
2.3.1 Total Dose Revision 23 The dose or dose commitment to any real MEMBER OF THE PUBLIC from all site sour9es is limited tq less than or equal to 25 mrem to the total body or any organ (except the thyroid, which is limited to less than or equal to 75 mrem) over a calendar year.
Applicability At all times.
ACTION With the calculated or projected dose from direct radiation contributions from the Independent Spent Fuel Storage Installation (ISFSI) determined to be, or projected to be, above the annual (calendar) limits of 2.3.1, prepare and submit to the commission within 30 days, pursuant to 10 CFR 50.4, a Special Report that defines the corrective action to be taken to reduce subsequent exceedences to prevent recurrence of exceeding the above limits and include the schedule for achieving conformance with the above limits. The Special Report shall include an analysis that estimates the radiation exposure (dose) to a member of the public from site sources for the calendar year covered by the report. It also shall describe levels of radiation and concentrations of radioactive material, if ahy, involved and the cause of the exposure levels or concentrations. If the estimated dose(s) exceeds the above limits, and if the exposure condition resulting in violation of 40 CFR 190 has not already been corrected, the Special Report shall include a request for a variance in accordance with the provisions of 40 CFR 190.11. Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.
8
SURVEILLANCE REQUIREMENTS Dose calculations - Cumulative dose contributions from direct radiation *shall be determined semi-annually in accordance with Section 2.3.2 of the ODCM.
Section 2.3.1 is provided to meet the dose limitations of 40 CFR 190.1 O(a) that have been incorporated into 10 CFR 20 by 46FR 18525. It requires the preparation and submittal of a Special Report whenever the calculated or projected doses from the site exceed the dose limits of 40 CFR 190.1 O(a). The Special Report will describe a course of action that should result in the limitation of the annual dose to a MEMBER OF THE PUBLIC to within the 40 CFR 190.1 O(a) limits. For the purposes of the Special Report, it may be assumed that the dose commitment to a MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible. If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR 190, the Special Report with a request for a variance (provided the release conditions resulting in violation of 40 CFR 190.10(a) have not already been corrected), in accordance with the provisions of 40 CFR 190.11 until NRC staff action is completed. The variance only relates to the limits of 40 CFR 190.1 O(a) and does not apply in any way to the other requirements for dose limitation of 1 O CFR 20 or 10 CFR 72.104(a).
2.3.2 Method to Calculate Direct Dose from ISF.SI Operations Section 2.3.1 restricts the dose to the whole body and any organ of any real MEMBERS OF THE PUBLIC at and beyond the Controlled Area Boundary from all site sources (including direct radiation) to the limit of 25 mrem in a year, except for the thyroid which is limited to 75 mrem in a year.
Estimates of direct exposure above background in areas at and beyond the Controlled Area Boundary can be determined from measurements made by environmental TLDs that are part of the Environmental Monitoring Program (Sections 2.1 and 2.2). A net response is determined by subtracting the average TLD value of the control stations from t~e semi-annual off-site TLD measurements. Realistic occupancy factors are then applied to the net exposure value. A positive net exposure is assumed if the net value is greater than the propagated uncertainty of the TLD indicator and control measurements. Alternatively, direct dose calculations from identified fixed sources on-site can be used to estimate the off-site direct dose contribution where TLD information may not be applicable.
Revision 23 9
3.0 REPORTING REQUIREMENTS 3.1 Annual Radiological Environmental Operating Report
- a.
An Annual Radiological Environmental Operating Report covering the operation of the ISFSI during the previous calendar year shall be submitted to the NRC by May 1 of each year.
- b.
The Annual Radiological Environmental Operating Report shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, including a comparison with operational controls (as appropriate), and previous environmental surveillance reports and an assessment of the observed impacts of the ISFSI operations on the environment.
The Annual Radiological Environmental Operating Report shall include summarized C!nd tabulated results of all radiological environmental monitoring during the report period pursuant to the table and figures in the ODCM. In the event that some results are not available to include in the report, the report shall be submitted noting and explaining the reasons for the missing results. If available, the missing data shall be submitted in the next annual report.
The report also shall include the following: a summary description of the Radiological Environmental Monitoring Program results with a map of all monitoring locations keyed to a table giving distances and directions from the ISFSI.
3.2 Annual Radioactive Effluent Release Report
- a.
By May 1 of each year, a report shall be submitted to the NRC covering the radioactive content of effluents released to unrestricted areas during the previous calendar year.
- b.
The Annual Radioactive Effluent Release Report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, Revision 1, June 1974, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Co.oled Nuclear Power Plants," with data summarized on a quarterly basis following the format of Appendix B thereof.
In addition, the Annual Radioactive Effluent Release Report shall include an assessment of the radiation doses due to the radioactive effluents released from the site during the previous year. This report also shall include an assessment of the radiation doses from radioactive effluents to MEMBER(S) OF THE PUBLIC due to the allowed recreational Revision 23 10
activities inside the SITE BOUNDARY during the previous year. All assumptions used in making these assessments (e.g., specific activity, exposure time, and location) shall be included in the report. The assessment of radiation doses shall be performed in accordance with the ODCM.
The Annual Radioactive Effluent Release Repo~ also shall include an assessment of radiation doses to the likely most exposed real MEMBER(S) OF THE PUBLIC from site activities to show conformance with 10 CFR 72.104(a) and 40 c*FR 190.10(a), if Section 2.3.1 limits has been exceeded during the calendar year.
The Annual Radioactive Effluent Release Report shall include a list and description of unplanned releases from the site to site boundary of radioactive materials in effluents made during the reporting period.
The Annual Radioactive Effluent Release Report shall include any changes made during the reporting period to the ODCM.
4.0 REFERENCES
- a.
Regulatory Guide 1.109, "Calculation of Annual Doses to Man From Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I," U.S. Nuclear Regulatory Commission, Revision 1, October 1977.
- b.
Y1;1nkee Atomic Electric Company Quality Assurance Program.
- c.
Letter from K. I. McConnell (NRC) to W. Norton (YAEC), Yankee Nuclear Power Station - Release of Land from Part 50 License, dated August 10, 2007.
- d.
1 O CFR 72.104, Criteria for radioactive materials in effluents and direct radiation from an ISFSI or MRS
- e.
40 CFR 190.10, Standards for normal operations.
- f.
40 CFR 190.11, Variances for unusual operations Revision 23 11