Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 April 25, 2016 Mr. Adam C. Heflin President, Chief Executive Officer, and Chief Nuclear Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, KS 66839
SUBJECT:
WOLF CREEK GENERATING STATION-REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST TO ALLOW USE OF OPTIMIZED ZIRLO' (CAC NO. MF7285)
Dear Mr. Heflin:
By letter dated January 27, 2016, Wolf Creek Nuclear Operating Corporation (the licensee) submitted to the U.S. Nuclear Regulatory Commission (NRC) a license amendment request to revise the Wolf Creek Generating Station (WCGS) Technical Specifications to allow the use of Optimized ZIRLO' as an approved fuel rod cladding.
The NRC staff has reviewed the information provided in your application and determined that additional information is required in order to complete its formal review. The enclosed questions were provided to Mr. J. Knust of your staff on April 12, 2016, and discussed in a telecon with Mr.
Knust, et al., of your staff on April 25, 2016. Please provide a response to the enclosed questions within 30 days of the date of this letter. If you have any questions, please contact me at 301-415-2296 or via e-mail at fred.lyon@nrc.gov.
Docket No. 50-482 Enclosure Request for Additional Information cc w/encl: Distribution via Listserv Sincerely, Carl F. Lyon, Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
REQUEST FOR ADDITIONAL INFORMATION WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION DOCKET NO. 50-482 By letter dated January 27, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16033A470), Wolf Creek Nuclear Operating Corporation (WCNOC, the licensee) submitted to the U.S. Nuclear Regulatory Commission (NRC) a license amendment request to revise the Wolf Creek Generating Station (WCGS) Technical Specifications to allow the use of Optimized ZIRLO' as an approved fuel rod cladding. The NRC staff has reviewed the information provided in the application and determined that the additional information below is required in order to complete its formal review.
Please demonstrate that that same thermal-hydraulic analysis and transient and accident analysis used (non-loss-of-coolant accident (LOCA); non-LOCA) for WCGS as described in References 1, 2, and 3 will not be impacted by the transition to Optimized ZIRLO'. This should include (1) demonstrating that the process is valid for all resident fuel designs licensed for WCGS, (2) demonstrating that the transition has no impact on both non-LOCA and LOCA analyses methodologies at WCGS, and (3) addressing the change to the cladding or structural materials for the fuel assembly skeleton and its impact on the thermal-hydraulic analysis.
Additionally, please provide the three references.
References:
- 1.
WCNOC Topical Report TR 90-0025 W01, "Core Thermal Hydraulic Analysis Methodology for the Wolf Creek Generating Station."
- 2.
WCNOC Topical Report NSAG-006, "Transient Analysis Methodology for the Wolf Creek Generating Station."
- 3.
WCNOC Topical Report NSAG-007, "Reload Safety Evaluation Methodology for the Wolf Creek Generating Station."
Enclosure
April 25, 2016 Mr. Adam C. Heflin President, Chief Executive Officer, and Chief Nuclear Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, KS 66839
SUBJECT:
WOLF CREEK GENERATING STATION-REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT REQUEST TO ALLOW USE OF OPTIMIZED ZIRLO' (CAC NO. MF7285)
Dear Mr. Heflin:
By letter dated January 27, 2016, Wolf Creek Nuclear Operating Corporation (the licensee) submitted to the U.S. Nuclear Regulatory Commission (NRC) a license amendment request to revise the Wolf Creek Generating Station (WCGS) Technical Specifications to allow the use of Optimized ZIRLO' as an approved fuel rod cladding.
The NRC staff has reviewed the information provided in your application and determined that additional information is required in order to complete its formal review. The enclosed questions were provided to Mr. J. Knust of your staff on April 12, 2016, and discussed in a telecon with Mr.
Knust, et al., of your staff on April 25, 2016. Please provide a response to the enclosed questions within 30 days of the date of this letter. If you have any questions, please contact me at 301-415-2296 or via e-mail at fred.lyon@nrc.gov.
Docket No. 50-482 Enclosure Sincerely,
/RA/
Carl F. Lyon, Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL4-1 r/f RidsACRS_MailCTR Resource RidsNrrDorllpl4-1 Resource RidsNrrDssSnpb Resource RidsNrrLAJBurkhardt Resource ADAMS A ccession No.: ML16110A372
- Previouslv concurred OFFICE NRR/DORL/LPL4-1/PM NRR/DORL/LPL4-1/LA NRR/OSS/SNPB/BC NAME Flyon JBurkhardt**
JDean*
DATE 04/25/16 04/20/16 04/12/16 RidsNrrPMWolfCreek Resource RidsRgn4MailCenter Resource JKaiser, NRR/DSS/SNPB
- email dated NRR/DORL/LPL4-1/BC NRR/OORL/LPL4-1 /PM RPascarelli Fl yon 04/25/16 04/25/16 OFFICIAL RECORD COPY